Your SlideShare is downloading. ×
Green Global Consulting's Bob Sharon at Global Telecom Week
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×

Introducing the official SlideShare app

Stunning, full-screen experience for iPhone and Android

Text the download link to your phone

Standard text messaging rates apply

Green Global Consulting's Bob Sharon at Global Telecom Week

98
views

Published on

Green Global Consulting's Bob Sharon at Global Telecom Week

Green Global Consulting's Bob Sharon at Global Telecom Week

Published in: Technology, Business

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
98
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
2
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide
  • 200 racks at just over 400sm at 900kw sensible cooling load n+1 each sideCOP of 12, producing a mechanical PUE of about 1.05
  • Transcript

    • 1. The Greenfield Data Centre Breaking 1:1 The Greenfield Data Centre Breaking 1:1 PUE
    • 2. Agenda 1. World’s Best DCs 2. Definitions 3. An Example 4. What is Modular Flexibility? 5. Critical Issues 6. Reliability & Costs 7. Q & A
    • 3. 1. World’s Best DCs Source – Data Centre Knowledge - Are You Suffering from PUE Envy? By: Industry Perspectives – 29 May 2 1.07 1.12 1.1 Lockport, NY USA iDataCenter, North Carolina Carbon-free hydroelectric power Wind power Fuel cells & solar power
    • 4. 2. Definitions • PUE • Where • Technology Religion • Agnosis
    • 5. 3.Example CRAC 1 CRAC 2 CRAC 3 CRAC 4 CRAC 5 ColdAisle ReturnHOTAIR ReturnHOTAIR ReturnHOTAIR ReturnHOTAIR ReturnHOTAIRReturnHOTAIR ReturnHOTAIR ReturnHOTAIR ColdAisle ColdAisle-Closed ColdAisle ColdAisle-Closed ColdAisle–Closed ColdAisle-Closed ColdAisle-Closed CRAC 6 CRAC 7 CRAC 8 CRAC 9 CRAC 10 EVAP 100kw EVAP 100kw EVAP 100kw EVAP 100kw EVAP 100kw EVAP 100kw EVAP 100kw EVAP 100kw EVAP 100kw EVAP 100kw
    • 6. 3.Example Raised Floor – 1,500m Office 45 sq. m. Hot Air Plenum Office 48 sq. m. EVAP 100s Air Intake Mixing Box Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey EVAP 100s Air Intake Mixing Box Supply air at 25/27 deg C Supply air at 25/27 deg C 30000.00 mm. x 5585.11 mm. Room Return Air Return Air Rack – Rear view Chi mn ey Rack – Rear view Chi mn ey
    • 7. 4.Whatis ModularFlexibility? CRAC 1 CRAC 2 CRAC 3 CRAC 4 CRAC 5 ColdAisle ColdAisle-Closed ColdAisle-Closed ColdAisle–Closed CRAC 6 CRAC 7 CRAC 8 CRAC 9 CRAC 10 EVAP 100kw EVAP 100kw EVAP 100kw EVAP 100kw EVAP 100kw EVAP 100kw EVAP 100kw EVAP 100kw EVAP 100kw EVAP 100kw Staging Area/DR 1 Staging Area/DR 2 Staging Area/DR 3 Staging Area/DR 4
    • 8. 5. Critical Issues a. Airflow management – EU CoC DC b. Air leakage – Delta T – Fans c. Outside air economisers d. Thermal fabric e. Power losses f. Flexibility – cooling dist, use of space, power g. Monitoring & DCIM h. Tier levels, reliability (no compromise) i. Innovation and more innovation j. IT infrastructure integration (Google) k. Attitude! Attitude! Attitude!
    • 9. 6. Reliability & Cost • The 9s • Do we need to spend more while improving quality? And how? • Can we maximise flexibility without the huge extra cost?
    • 10. I Challenge You! To achieve a greenfield data centre with a PUE of 1.1 in Melbourne, Canberra or Tasmania
    • 11. 7. Q & A Thank you!