Cisco Nexus 1000V for Microsoft Hyper-V Webinar March 6
 

Cisco Nexus 1000V for Microsoft Hyper-V Webinar March 6

on

  • 1,806 views

Using or looking at Hyper-V for your workloads? Learn how the Cisco Nexus 1000V virtual access/distributed switch can help simplify your Hyper-V virtual environment through a non-disruptive ...

Using or looking at Hyper-V for your workloads? Learn how the Cisco Nexus 1000V virtual access/distributed switch can help simplify your Hyper-V virtual environment through a non-disruptive operational model, policy based provisioning, and a strong services ecosystem. You will learn about the Cisco Nexus 1000V architecture, how it integrates with Microsoft's System Center Virtual Machine Manager (SCVMM) and the rich networking capabilities it brings to Hyper-V environments.

Integrated into the Windows Server 2012 Extensible Switch, and fully compatible with System Center Virtual Machine Manager 2012 SP1, the Cisco® Nexus 1000V Series provides:
Advanced virtual machine networking based on Cisco NX-OS operating system and IEEE 802.1Q switching technology
Cisco vPath technology for efficient and optimized integration of virtual network services
Tight integration with System Center Virtual Machine Manager 2012 SP1
Layer 2 Switching with Transmit side Rate Limiting
Security Policy Mobility, inbuilt support for Private VLANs with local PVLAN Enforcement
Provisioning Port Profiles with deep Integration with SCVMM
Traffic Visibility, including VM Migration Tracking, NetFlow v.9 with NDE, Cisco Discovery Protocol v.2
And so much more
ON-DEMAND RECORDING HERE : https://cisco.webex.com/ciscosales/lsr.php?AT=pb&SP=EC&rID=66514357&rKey=7b25fe3bee5c4796
ACCESS TO THE ON-LINE NEXUS 1000V COMMUNITY :
https://communities.cisco.com/community/technology/datacenter/nexus1000v

Statistics

Views

Total Views
1,806
Views on SlideShare
1,806
Embed Views
0

Actions

Likes
0
Downloads
49
Comments
0

0 Embeds 0

No embeds

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

    Cisco Nexus 1000V for Microsoft Hyper-V Webinar March 6 Cisco Nexus 1000V for Microsoft Hyper-V Webinar March 6 Presentation Transcript

    • Cisco Nexus 1000V for Microsoft Hyper-VDamian Flynn, MVP Cloud and Datacenter & Infrastructure Architect, LionbridgeGunnar Anderson, Product Marketing Manager, Cloud Networking & Services, CiscoAppaji Malla, Sr. Product Marketing Manager, Cloud Networking & Services, CiscoSai Chaitanya, Technical Marketing Engineer, Cloud Networking & Services, Cisco
    • Date/Time Topic Cisco Open Network Environment (Cisco ONE) – Next Phase of Network ProgrammabilityThur, Feb 21st at 0900 PST and SDNThur, Feb 28th at 0900 PST Cisco One Platform Kit (onePK): Technical Deep Dive and key use casesWed, Mar 6th at 0900 PST Nexus 1000V for Hyper-V with Microsoft SCVMM integrationWed, Mar 13th at 0900 PST Cisco ONE controller: Technical Deep Dive and key use cases 5000 Seat VDI Reference Architecture: Cisco UCS & Nexus 1000V, Citrix XenDesktop, andWed, Mar 20th at 0900 PST EMC VNXWed, Mar 27th at 0900 PST Nexus 1000V v2.2 for vSphere: More scale, Multicast-less VXLAN, VXLAN GatewayWed, April 3rd at 0900 PST Cloud Services Router (CSR 1000V): Technical deep dive and key use casesWed, April 10th at 0900 PST Cloud Security with ASA 1000V and Virtual Security Gateway v2.1 (VSG)Wed, April 17th at 0900 PST Secure Hybrid Cloud solution with Nexus 1000V InterCloud & VNMC InterCloudWed, April 24th at 0900 PST Nexus 1100 for Cloud Network Services: New Services & EcosystemWed, May 1st at 0900 PST Cloud Networking Services: vNAM and vWAASWed, May 8th at 0900 PST Virtualized Multiservice Data Center (VMDC) solution with Cloud Networking ServicesWed, May 15th at 0900 PST Nexus 1000V for KVM (with OpenStack and VXLAN) Register and view recordings/presentations here: www.cisco.com/go/1000vcommunity © 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 2
    • Many of the products and features describedherein remain in varying stages of developmentand will be offered on a when-and-if-availablebasis. This roadmap is subject to change at thesole discretion of Cisco, and Cisco will have noliability for delay in the delivery or failure todeliver any of the products or features set forthin this document.© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 3
    • • Cisco Virtual Networking Solutions• WS2012 & SCVMM 2012 Networking Overview• Nexus 1000V architecture• N1KV Integration with SCVMM• Virtual Services• How to participate in Public Beta• Live Demo© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 4
    • MaturingOperational Virtual Public Resource HypervisorComplexity market Services Cloud Utilization Managing  Economics  Secure virtual  Security  VM Mobility networks environment concerns for across DC  Use-cases across public cloud  Mobility requiring  Rich network physical & different services  Mobility across DCs virtual hypervisors concerns  Mobility environments across clouds Consistent Multi- Multi-services Overlay Multi-cloud Operational hypervisor support with Technology support Model Support vPath Support Diverse Virtualization Requirements for DataCenter Customers© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 5
    • PHYSICAL VIRTUAL CLOUD WORKLOAD WORKLOAD WORKLOAD • One app per Server • Many apps per Server • Multi-tenant per Server • Static • Mobile • Elastic • Manual provisioning • Dynamic provisioning • Automated Scaling HYPERVISOR VDC-1 VDC-2 CONSISTENCY: Policy, Features, Security, ManagementSwitching Nexus 7K/5K/3K/2K Nexus 1000V, VM-FEXRouting ASR Cloud Services Router (CSR 1000V)Services WAAS, ASA, NAM Virtual WAAS, VSG, ASA 1000V, vNAM*Compute UCS for Bare Metal UCS for Virtualized Workloads © 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 6
    • Nexus 1000V Multi-Cloud Multi-Services Multi-Hypervisor© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 7
    • Compute Networking Manageability  Cisco Unified Computing  Cisco Nexus 1000V  Cisco UCS Manager (UCS)  Cisco UCS VM-FEX  Cisco UCS PowerTool Certified for various Microsoft applications© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 8
    • © 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 9
    • • What is the pricing associated with Nexus 1000V for Hyper-V? Ans: It will be consistent with the existing product.• Does the product work with all vesions of Hyper-V? Ans: the product works only with Hyper-V 3.0 – that version that is shipped with WS2012. Also, you need to have SCVMM 2012 to use N1KV.• Can the same N1KV manage both ESX & Hyper-V? Ans: No. Sepearate N1KV switches should be deployed for different hypervisor environments.© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 10
    • Damian Flynn is the Infrastructure Architect on the Corporate IT team. His current focus is on Software Defined Networks (SDN) with “Azure for Window Server Services”, with perspective on Orchestration of repeatable processes in “Dev/Ops” scenarios. He has a keen interest in Cloud Computing from both a business strategy and technical viewpoint and has presented sessions on building and managing Private/Hybrid Clouds at a number of industry events. Damian authored the Cloud chapters on two books, is active in many MS Programs, blogs at www.damianflynn.com, tweets at @damian_flynn, and and has published a number of white papers and technical articles.© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 11
    • • Cisco Virtual Networking Solutions• WS2012 & SCVMM 2012 Networking Overview• Nexus 1000V architecture• N1KV Integration with SCVMM• Virtual Services• How to participate in Public Beta• Live Demo© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 12
    • © 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 13
    • • Hyper-V extensible switch “A virtual Ethernet switch that runs in the managementoperating system of the Hyper-V parent partition. Through theuse of extensions, independent software vendors (ISVs) canextend the switch functionality.” Benefits Extensibility Manageability  SR-IOV  Windows PowerShell  Dynamic VMQ  Unified tracing, capture &  Port Mirror & ACL  Cisco Nexus 1000V diagnostics  IPsec Offload & QOS  Cisco UCS VM-FEX© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 14
    • • VHDX support• Storage Enhancements Windows Standards-Based Storage Management Thin provisioning of logical units, and for the discovery of SAS storage• Hyper-V Host Provisioning Deep discovery with detailed information about physical network adapters• VMM Console Add-Ins Enable new actions or additional configuration for VMM objects Embed custom WPF UI or Web Portals• Enhanced Networking Architecture Network Virtualization Extensible Switch, Extension Support© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 15
    • © 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 16
    • LOGICAL PLAN Virtual Machine Networking VLAN-based configuration - You can continue to use familiar No VM networking – No isolation – You can get direct Network virtualization – You can support multiple tenants Use external networks – You can use a vendor virtual local area network (VLAN) technology for network isolation. Networks that don t access to the logical network with a (also called clients or customers) with their own networks, network-management console that allows you require access by VMs VM network. Appropriate for a host isolated from the networks of others. to configure settings on your forwarding do not use VM management or shared Internet extension. VMM will import those settings. networks. For example, networks. storage networks.Virtual Machine Networks Tenant 1 Tenant 2 Internet All Tenants Tenant 3 Tenant 4 Tenant 5 10.0.1.0/24 10.0.1.0/24 Various Subnets 10.0.1.0/24 10.0.1.0/24 10.0.1.0/24 External Hyper-V Network Virtualization Filter Isolation method for external networks is not visible to VMM. Logical Network VLAN Isolated Storage Internet Provider Network External Network NetworksLogical Network Site (Logical VLAN 5 VLAN 15 VLAN 10 A B VLAN 0 VLAN 25 VLAN 30 VLAN 35 Network 10.0.1.0/24 10.0.1.0/24 10.0.1.0/24 10.0.1.0/24 Definition) © 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 17
    • © 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 18 1
    • Port-Classifications • Provide a level of indirection to Virtual Port Profiles • Provide a way to group Port Bundling of profiles from each extension is Profiles from different Hyper-V the port-classification switch extensions© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 19
    • • Cisco Virtual Networking Solutions• WS2012 & SCVMM 2012 Networking Overview• Nexus 1000V architecture• N1KV Integration with SCVMM• Virtual Services• How to participate in Public Beta• Live Demo© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 20
    • VM VM VM VM Advanced NX-OS feature-set VNICs Nexus 1000V VEM Nexus 1000V VSM SCVMM Integration Extensible vSwitch vPath Services architecture Consistent operational PNICs model© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 21
    • Virtual Appliance VSM-1 (active) Network Admin NX-OS VSM-2 (standby) Control Plane Supervisor-1 (Active) Supervisor-2 (StandBy) Back Plane Linecard-1 Linecard-2 … NX-OS Linecard-N Data Plane Modular Switch VEM-1 VEM-2 VEM-N WS 2012 Hyper-V WS 2012 Hyper-V WS 2012 Hyper-VVSM: Virtual Supervisor Module ServerVEM: Virtual Ethernet Module Admin © 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 22
    • VM VM VM VM VM VM VM VM VM VM VM VM Cisco Cisco Cisco Nexus Nexus Nexus 1000V 1000V 1000V VEM VEM VEM WS 2012 Hyper-V WS 2012 Hyper-V WS 2012 Hyper-V Server Server ServerVirtual Supervisor Module (VSM) Virtual Ethernet Module (VEM)• Virtual or Physical appliance running • Enables advanced networking Cisco NXOS (supports Hi-availability) capability on the hypervisor• Performs management, monitoring, • Provides each virtual machine with and configuration dedicated “switch port”• Tight integration with management • Collection of VEMs : 1 virtual network platforms Distributed Switch Cisco Nexus 1000V VSM © 2010 Cisco and/or its affiliates. All rights reserved. System Center Virtual Machine Manager Cisco Confidential 23
    •  L2 Switching, 802.1Q Tagging, Rate Limiting (TX) Switching  IGMP Snooping, QoS Marking (COS & DSCP)  Policy Mobility, Private VLANs w/ local PVLAN Enforcement Security  Access Control Lists (L2–4 w/ Redirect), Port Security  Dynamic ARP inspection*, IP Source Guard*, DHCP Snooping*  Virtual Services Datapath (vPath) support for traffic steering & fast-pathNetwork Services off-load [leveraged by Virtual Security Gateway (VSG) and other services]  Full integration with System Center – VM Manager (SCVMM) Provisioning  Faster network policy provisioning through port profiles  Live Migration Tracking, NetFlow v.9 w/ NDE, CDP v.2 Visibility  VM-Level Interface Statistics  SPAN & ERSPAN (policy-based)  VM Network Provisioning (port-profiles), CiscoWorks, Cisco DCNM Management  Cisco CLI, Radius, TACACs, Syslog, SNMP (v.1, 2, 3)  Hitless upgrade, SW Installer © 2010 Cisco and/or its affiliates. All rights reserved. * Only with Advanced Edition Cisco Confidential 24
    • SCVMM manages the placement and live-migration of the VMs based on VM VM VM VM the constraints between VM networks and the network sites. Server Admin Nexus SCVMM Adds hosts to N1KV 1000V Connects VMs (VNICs) to VEM VM Networks Win 8 Hyper-V Networks & policies synced to SCVMM Server Network Create networks and Admin Nexus 1000V policies (logical VSM networks, network sites, VMnetworks)© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 25
    • Provide SCVMM Credentials Provide Host info for Primary & Secondary VSM© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 26
    • • Why the Nexus 1000V, and my WS2012 experience?• Alpha New concepts for the Server Administrator (Let it go!) What VSM, VEM, VFEX… Tricky Installation, and lots of NX-OS CLI• Beta NX-OS maturing commands Familiar environment for the Network Engineer Unification with Microsoft WS/SC terminology, and VMM concepts• Public Beta Unified management for Physical and Virtual Infrastructure Reduced time to resolution, via NX-OS access to the Virtual NIC© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 27
    • • Return the Status Quo Hyper-V Administrator are not Network Engineers (Honestly!)• Deliver Consistency Physical and Virtual Networks implement consistent policies Network Engineers manage both the Physical and Virtual Networks Server Engineers manage the Compute and Storage• Elasticity Vastly simplified host networking configuration Faster, repeatable and consistent host provisioning Clear segregation of ownership, accelerated problem resolution• Business Process Improvements VMs and Physical devices are first class end points on the network Standardized Policies for Tracing, Monitoring, Management, Debugging Consistent Network visibility in the hybrid environment© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 28
    • • Cisco Virtual Networking Solutions• WS2012 & SCVMM 2012 Networking Overview• Nexus 1000V architecture• N1KV Integration with SCVMM• Virtual Services (N1KV)• How to participate in Public Beta• Live Demo© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 29
    • # network-segment-poool Intranet_POD1 VM Network Intranet_POD1_SUBNET1# network-segment Intranet_POD1_SUBNET1switchport mode access VM Network Intranet_POD1_SUBNET2switchport access vlan 20 VM Network Intranet_POD1_SUBNET3ip-pool Intranet_POD1_Pool1network-definition Intranet_POD1 Network Site “Intranet_POD1”# network-segment Intranet_POD1_SUBNET2switchport mode access • A Network Site is aswitchport access vlan 21 grouping of VM Networks thatip-pool Intranet_POD1_Pool2 are always available togethernetwork-definition Intranet_POD1 on the same host# network-segment Intranet_POD1_SUBNET3 simultaneouslyswitchport mode accessswitchport access vlan 22 • A host uplink can beip-pool Intranet_POD1_Pool2 configured to carry one ornetwork-definition Intranet_POD1 more Network Sites© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 30
    • Cisco Virtual Networking Policy-Based Mobility of Network and Non-Disruptive VM Connectivity Security Properties Operational Model Port Profiles VM VM VM VM VM VM VM VM Defined Policies WEB Apps Nexus Nexus HR 1000V 1000V VEM VEM DB Hypervisor Hypervisor DMZ VM Connection Policy Server Server • Defined in the network • Applied in SCVMM VM Mgmt Station Nexus 1000V VSM© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 31
    • Cisco Virtual Networking Policy-Based Mobility of Network and Non-Disruptive VM Connectivity Security Properties Operational Model VM VM VM VM VM VM VM VM VM VM VM VM VMs Need to Move • VM Migration Nexus Nexus 1000V 1000V • Resource Scheduling VEM VEM • SW upgrade/patch Hypervisor Hypervisor • Hardware failure VM Networking Mobility Server Server • Live Migration • Ensures VM security • Maintains connection state VM Mgmt Station Nexus 1000V VSM© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 32
    • DB Clients DB Servers VM VM VM VM DB Network Current N1KV/ESX Version N1KV/Hyper-V Version# port-profile db-client # network-segment db-networkswitchport mode access switchport mode accessswitchport access vlan 10 switchport access vlan 10ip port access-group dbclient inno shut # port-profile db-clientstate enabled ip port access-group dbclient in no shut# port-profile db-server state enabledswitchport mode accessswitchport access vlan 10 # port-profile db-serverip port access-group dbserver in ip port access-group dbserver inno shut no shutstate enabled state enabled© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 33
    • Basic Parameters Required for API Calls Read/Write Object (IP Pool)$User = "admin" #Update IP-Pool Information - HTTP POST$Password = ConvertTo-SecureString –String $IPPURI=$URI +"hyper-v/ip-address-pool/pool1""Secret123" –AsPlainText -Force $IPPArg = {"name":"pool1",$VSMIPaddress = "10.105.228.108" "addressRangeStart":"192.168.0.2",$URI = "http://"+ $VSMIPaddress + “/api/” "addressRangeEnd":"192.168.0.16"}‘$Credentials = New-Object –TypeName ConvertFrom-Json -InputObject $IPPArgSystem.Management.Automation.PSCredential – Invoke-RestMethod -Uri $IPPURI -CredentialArgumentList $User, $Password $Credential -Method Post -Body $IPPArg DELETE Object (VM network) #$VMNURI = $URI +"hyper-v/vm-network-definition/vmn4" $VMNArg = {"name":"VMN4"}‘ ConvertFrom-Json -InputObject $VMNArg Invoke-RestMethod -Uri $VMNURI -Credential $Credential -Method Delete -Body $VMNArg © 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 34
    • • Xian SCOM Plugin for Nexus 1000V• Monitors various metrics: Availability (ICMP and SNMP) TCP Connections Uptime Traffic, total, error etc. Bandwidth© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 35 3
    • • Cisco Virtual Networking Solutions• WS2012 & SCVMM 2012 Networking Overview• Nexus 1000V architecture• N1KV Integration with SCVMM• Virtual Services (N1KV)• How to participate in Public Beta• Live Demo© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 36
    • VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM Virtual Security 4 Gateway (VSG)* Nexus 1000V vPath Distributed Virtual Switch Decision Caching 3 Initial Packet 2 Flow Access Control 1 Flow (policy evaluation) Log/Audit© 2010 Cisco and/or its affiliates. All rights reserved. * First version only supports network attributes Cisco Confidential 37
    • VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM Virtual Security Gateway (VSG)* Nexus 1000V vPath Distributed Virtual Switch ACL offloaded to Nexus 1000V (policy enforcement) Remaining packets from flow Log/Audit© 2010 Cisco and/or its affiliates. All rights reserved. * First version only supports network attributes Cisco Confidential 38
    • • Cisco Virtual Networking Solutions• WS2012 & SCVMM 2012 Networking Overview• Nexus 1000V architecture• N1KV Integration with SCVMM• Virtual Services (N1KV)• How to participate in Public Beta• Live Demo© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 39
    • High Touch Beta Public Beta• Over-subscribed. • Available to all participants that have a• We have quite a number of valid email-id, company name, and participants that wanted to be part of contact adress the hi-touch beta • That are willing to test the product and provide constructive feedback • Participate in the discussion forums, and contribute to the N1KV communitt© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 40
    • beta-n1kv-hyperv@cisco.com© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 41
    • • Cisco Nexus 1000V software Virtual Supervisor Module (VSM) ISO (n1000vh-dk9.5.2.1.SM1.5.0.1.iso) Virtual Ethernet Module (VEM) MSI package (Nexus1000V.msi) VSEM Provider MSI Package (CiscoProviderInstaller.msi) N1KV Installer App (Cisco Nexus 1000V Installer)• Installation Document & Screencast Getting Started Guide for Cisco Nexus 1000V for Microsoft Hyper-V• Beta Test-cases Document Outlines sample test cases and configurations for the alpha features• Cisco Nexus 1000V Beta Process Overview Presentation• Documentation© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 42
    • • Cisco Virtual Networking Solutions• WS2012 & SCVMM 2012 Networking Overview• Nexus 1000V architecture• N1KV Integration with SCVMM• Virtual Services (N1KV)• How to participate in Public Beta• Live Demo© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 43
    • Nexus WebServer SCVMM Employee Contractor 1000V VM VM VM VM VSM HyperV Nexus 1000V Nexus 1000V Switch VEM -1 VEM -2 HOST01 HOST02 HOST03© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 44
    • Use Case 1 – Security using Access Control Lists Employee Contractor Web Server Configure the port-profiles so Nexus Nexus that web-server access is 1000V 1000V restricted: • Employee can access VEM VEM Win 2012 Hyper-V Win 2012 Hyper-V • Contractor is restricted Nexus 1000V VSM© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 45
    • Use Case 2 – Traffic Monitoring usingEncapsulated Route Span (ERSPAN) Employee Contractor Web Server  Configure a ERSPAN Nexus Nexus session on WebServer 1000V VEM 1000V VEM VM interface Win 2012 Hyper-V Win 2012 Hyper-V  Monitor the traffic the vNAM running on Nexus 1110 VNAM Nexus 1000V VSM© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 46
    • Use Case 3 – Policy (SPAN) maintainedacross Live Migration Employee Contractor Web Server  Live Migrate the VM Nexus Nexus 1000V VEM 1000V VEM  Demonstrate that SPAN session is maintained. Win 2012 Hyper-V Win 2012 Hyper-V VNAM Nexus 1000V VSM© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 47
    • • Cisco-Microsoft Partnership: http://www.cisco.com/go/microsoft• Cisco Nexus 1000V: http://www.cisco.com/go/nexus1000v• Cisco UCS VM-FEX: http://www.cisco.com/go/vmfex• Solution Overview: http://www.cisco.com/en/US/solutions/collateral/ns340/ns517/ns2 24/ns955/ns963/solution_overview_c22-687087.html• Q&A Doc: http://www.cisco.com/en/US/solutions/collateral/ns340/ns517/ns2 24/ns955/ns963/faq_c67_687090_ns1154_Networking_Solutions _Q_and_A.html© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 48
    • Thank you.