Your SlideShare is downloading. ×
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×
Saving this for later? Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime – even offline.
Text the download link to your phone
Standard text messaging rates apply

Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

606

Published on

For over 20 years DENIOS has been the worldwide leader in the design and manufacture of custom engineered chemical storage structures. Working directly with our customers we help assess risks and …

For over 20 years DENIOS has been the worldwide leader in the design and manufacture of custom engineered chemical storage structures. Working directly with our customers we help assess risks and provide solutions for the safe storage and containment of hazardous chemicals and processes.

Published in: Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
606
On Slideshare
0
From Embeds
0
Number of Embeds
1
Actions
Shares
0
Downloads
8
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. Chemical Storage Cabinets Chemical Storage Buildings Customized Enclosures – Temperature Controlled and Fire Rated Designs Chemical Storage Lockers Steel Spill Decking Systems Automatic Doorway Spill Barriers Large Capacity Containment Berms – The HazBerm Chemical Storage and Hazardous Process Containment Technology The environment‘s partner 1 1
  • 2. DENIOS, your partner in safety and environmental protection 2 For over 20 years DENIOS has been the worldwide leader in the design and manufacture of custom engineered chemical storage structures. Working directly with our customers we help assess risks and provide solutions for the safe storage and containment of hazardous chemicals and processes. DENIOS ENGINEERING provides you Table of Contents Introduction DENIOS Storage Lockers 4 Overview – Codes and Regulations Governing the Storage of Hazardous Chemicals and Processes 46 Introduction to Chemical Storage Lockers 48 K-Series Storage Lockers 49 K-Series Storage Lockers- Shelf Package DENIOS Storage Cabinets 50 PK-Series Storage Lockers 6 Introduction to Chemical Storage Cabinets 52 N-Series Storage Lockers 8 FM Approved Storage Cabinets 55 IBC Storage Lockers 9 FM Approved Storage Cabinets – Drums 57 Specialty Storage Lockers 10 FM Approved Storage Cabinets – IBC Totes 58 Custom Engineered Storage Lockers 11 FM Approved Storage Cabinets – 2-Hour Fire Rated 59 Storage Locker Options 12 Storage Cabinets – IBC Totes 60 Enclosed HazMat Stations 16 Storage Cabinets – Drums Expertise in helping you meet applicable laws and regulations. DENIOS not only knows the regulations, we work directly with leading insurers, risk managers, and government authorities in developing new equipment or setting performance standards for existing designs and construction. We will work with you in meeting Federal standards as well as those of your local authorities, helping make sure your DENIOS products are in complete compliance. 20 Basic Storage Cabinets 22 Horizontal Storage Cabinets 23 24 26 Temperature Controlled Storage Cabinets 28 Storage Cabinet Options DENIOS Storage Buildings 30 Introduction to Chemical Storage Buildings 68 Storage of Flammable Liquids 32 Premium Storage Buildings – 8’ Depth 69 Chemical Spill Containment Requirements When we put a DENIOS label on your product it’s to let you know we stand behind what we design and manufacture, and that we’re here for you well after the sale is completed. 34 Premium Storage Buildings – 10’ Depth 70 Storage of Organic Peroxides 36 Premium Storage Buildings – 12’ Depth 72 Third Party Approvals 38 Custom Engineered Storage Buildings 40 Fire Rated Storage Buildings 42 Temperature Controlled Storage Buildings 44 Storage Building Options A complete understanding of hazardous chemicals and chemical processes. Our Technical Sales and Engineering Staff know specific chemicals and the risks they pose to facilities, personnel, and the environment. They will work with you every step of the way in designing a safe storage solution for your individual applications. DENIOS Liquid Barriers 62 Automatic Doorway Spill Barriers Custom Engineered Cabinets 64 FM Approved Flood Barrier Fire Rated Storage Cabinets 65 HazBerm Guide to Chemical Storage 66 The Basics for the Handling and Storage of Flammable Chemicals – Definitions 3
  • 3. Overview – Codes and Regulations Governing the Storage of Hazardous Chemicals and Processes Introduction Governmental codes and regulations dictate the correct selection and placement of hazardous chemical storage Lockers, Cabinets and Buildings. The characteristics of the stored material i.e. flammability, pH, material storage temperature, the size and type of container(s), the total quantity stored, and the storage location in relation to other structures will determine which code(s) and regulations pertain to your application. Regulations and Codes of note that may affect your storage application are NFPA 30 “Storage of Flammable Liquids”, the IBC and IFC “International Building Code” and International Fire Code”, as well as the code of Federal regulations 40 CFR 264.175 concerning containment and 29 CFR 1910 (OSHA). Additionally independent third party testing agencies such as Factory Mutual have developed standards for the storage of flammable and other hazardous materials. DENIOS sells and produces Factory Mutual approved products. DENIOS sales and engineering professionals are well versed in the requirements of National codes as they pertain to the storage of hazardous chemicals. However, the local code enforcement official or “Authority Having Jurisdiction” is the official closest to the situation with the responsibility to interpret the applicable codes in the light of all local factors. The local “AHJ” should always be consulted before purchasing any type of hazardous material storage equipment. DENIOS is always available to assist its customers with supplementary information to support approval process. DENIOS’ Quality Assurance Program As part of our ongoing commitment to quality, DENIOS maintains a formalized, structured Quality Assurance Program. This program mandates that designs are checked and rechecked by 3rd Party Engineering firms for structural loading, seismic, and other code compliance factors. DENIOS equipment is also engineered to satisfy any number of regulatory agencies including: NFPA – National Fire Protection Association – International Building Code IBC – Environmental Protection Agency EPA OSHA – Occupational Safety and Health Administration / FM Global – Factory Mutual Research FM State Approval Departments Relating to equipment manufacture, our Quality Assurance Program also insures all products are thoroughly inspected and tested before shipping. Tests range from, but are not limited to, pre-paint sump weld leak tests to temperature control tests for our heated and cooled structures. Testing is documented and overseen by our Engineering, Technical Sales, and Production staffs. The DENIOS System The DENIOS System of storage Lockers, Buildings, and Cabinets specifically address the material handling and processing needs of the client. All our structures are designed for placement indoors or out and can be easily relocated via crane or forklift. All provide options for fire rating, explosion protection, and temperature control. All designs address what and how much is being stored and how often it needs to be handled. And all are compliant. Lockers: Engineered for small volume storage and processing, Lockers will accommodate 2-14 drums or 1-2 intermediate bulk containers. Available door styles allow for easy access to the chemicals by forklift. Typical uses include exterior storage of flammables and combustibles, remote storage and dispensing stations for truck and rail terminals, and insulated and heated storage for processing and freeze protection. Cabinets: Designed for large volume storage needs, Cabinets come with single- or double-sided access and provide up to three tiers and 12 bays of storage space. A variety of door styles all allow for forklift access to every stored pallet of drums, thus simplifying handling and eliminating any personnel exposure to chemicals or fumes inside the Cabinet. Buildings: Often utilized for housing dangerous processes such as mixing and pumping flammable paints and resins, Buildings provide a secure enclosure isolating any hazardous chemical dispensing, mixing, and processing away from personnel and the rest of the facility. Chemical Storage Equipment Selection Guide Chemical Storage Requirement Size of Container Quantity Quantity totes 55 gallon drums 5 gallons or less more than 8 drums less 1-2 than 8 totes drums yes roomful of totes roomful of drums 3-12 totes On Pallets? up to 36 pallets of containers no less than 40 5 gallon containers more than 40 5 gallon containers DENIOS Spill Barrier 4 Quantity DENIOS Cabinet DENIOS Locker DENIOS Building 5
  • 4. Introduction to Chemical Storage Cabinets A Safer Storage Alternative DENIOS is the pioneer in the development of Drum and IBC Storage Cabinets as a safer and more efficient alternative to walk-in buildings for chemical storage. The non-occupancy design of Cabinets, featuring full-face opening door styles, allows all materials to be moved via forklift, relieving personnel from having to enter a potentially hazardous environment. DENIOS manufactures the widest variety of styles of Cabinets available on the market today. Choose between single- or multi-tiered designs with either single- or double-sided access. Cabinets are suitable for indoor or outdoor placement and provide complete physical separation of stored chemicals from the surrounding facility and / or from other incompatible chemicals or ignition sources. Sizes and Styles: 48 standard configurations of base models ndividual storage bays sized for 2 or I 3 pallets of drums or 2 or 3 IBC’s ays are arranged in configurations offering B single-, double- or triple-tier heights odels are available with single-sided or M double-sided access (back-to-back bays) ll units are built to accommodate A outdoor placement Common Applications for Cabinets: Segregated indoor or outdoor storage of flammable or other process chemicals Separation of flammable liquids from general warehousing areas Temperature controlled outdoor storage of raw materials igher volume waste accumulation H and storage areas Applicable Regulations How should substances be stored? DENIOS Cabinets meet the federal requirements for spill containment of hazardous liquids as regulated by the EPA (40 CFR). DENIOS follows NFPA 30 regulations for specification compliance for outdoor (Flammable Storage Lockers) as well as indoor (Inside Liquid Storage Rooms) placement. Although not designated as Occupancies or Structures, loads ratings for Cabinets (seismic, wind and roof) generally follow the same guidelines as provided for pre-fabricated buildings. Storing drums directly Storing drums on pallets Storing IBCs Range of door options- all doors lockable Storing drums horizontally Freeze protected Cabinet designs are able to be provided with 3rd Party Engineering Approvals. Choose between single-, double- and triple-tier models Multiple door styles (hinged, sliding,and roll-up) all provide full-face opening for easy access to drums / IBCs Lifting eyes allow for easy relocation Due to local code variance and different enforcement philosophies, DENIOS always recommends checking with the local Authority Having Jurisdiction to verify that a specific configuration will comply with local codes. Sliding doors Hinged doors Roll-up doors Insulated system For your further reference Hazardous materials storage is regulated by EPA at the federal level by the Code of Federal Regulations (40 CFR). Fire Rated designs up to 4-hour, heating systems for Freeze Protected At the state and local level, Fire Codes such as IFC, UFC, NFPA 30 (Storage and Handling of Flammable Liquids), Building Codes (UBC IBC) and other requirements specific to State and Local jurisdictions may also apply. Typical local code issues include: wind load, snow load, seismic zone, fire rating and separation of flammable storage from the nearest building. Benefit from our Experience DENIOS has been designing and manufacturing chemical storage enclosures for over 20 years. Constructed of an 11 gauge tubular frame with 16 gauge steel walls 6 Perfect for storing and handling palleted drums and IBC totes Compliant spill containment sump sits below galvanized grating Feet for forklift access allow for easy relocation By working closely with customers in solving their unique storage challenges, we have been able to translate those solutions into standard products which can provide compliant storage for a majority of industries and applications. Roofing systems can be added to Cabinets or Buildings to create covered storage warehouses. International Fire Code (IFC) International Building Code (IBC) Code of Federal Regulations (CFR) Environmental Protection Act (EPA) National Fire Protection Assn. (NFPA) Uniform Fire Code (UFC) Uniform Building Code (UBC) FM 6049 7
  • 5. FM Approved Storage Cabinets Exclusive to DENIOS, FM Approval (Class 6049) Non-Occupancy Storage Cabinets The First Cabinet to Meet the Standard Third party approvals for Hazardous Material Buildings have been around since 1991 in the form of FM class 6049. FM began approving hazardous material storage buildings with the first edition of CLASS 6049 in that year. This FM “standard” has remained the defacto standard in the US, unchallenged since that time. Manufacturers that receive FM approval have submitted their designs to a third party and then to FM for review in accordance with the standard. This includes reviewing the structural integrity including floor and snow loads in accordance with the standards and the ability of the building to withstand a specific wind which is especially important in coastal areas of the US. The standard further evaluates the integrity of fire rated walls and ceiling and certifies the stated containment sump capacity. Contrary to popular opinion, UL (Underwriters Laboratories) does not have a standard for these buildings, so no manufacturer can use the “UL listed” moniker with reference to their buildings. Designed and sized for 350 gallon IBC Totes or 55 gallon drums A FM approved building should be labeled as such by the manufacturer. The text of the approval document prescribes what must be on the label. This includes place of manufacture, model no., design floor, wind and snow loads, and if applicable, the fire rating of the walls. It also includes whether the building is constructed with damage limiting construction (DLC) also known as deflagration panels, and the electrical classification and temperature classification of any and all electrical equipment installed on the building. Storage capacities from 2 to 12 totes or 8 to 48 drums Choose between models with hinged or sliding doors, both allow easy access to totes / drums from outside the Cabinet Sump volumes meet EPA, NFPA, and FM requirements Low-viscous test ensures sumps are leak free onstructed of heavy gauge, welded steel C frames and walls Contact Us: DENIOS-Leading Supplier of FM Approved Chemical Containment Products. For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l info2@denios-us.com vailable in single- and double-tiered designs A with up to four storage bays DENIOS’ FM Approved fire rated Cabinet. DENIOS is presently the only manufacturer with FM Approved Cabinets. Single-Sided Access — Hinged Doors Capacity per Cabinet (Drums) Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Length Depth Height Length Depth Sump Volume (gal) L30-1111 8 11 5 8 108 50 80 3,000 7,500 141 L30-1311 12 15 5 8 154 50 80 3,400 9,600 201 L30-1211 16 21 5 8 108 50 80 5,100 7,500 289 L30-1411 24 28 5 8 154 50 80 6,300 9,600 410 L30-2111 16 11 5 11 108 50 50 3,200 7,500 230 L30-2311 24 15 5 11 154 50 50 3,400 9,600 330 L30-2211 32 21 5 11 108 50 50 5,300 7,500 470 L30-2411 48 28 5 11 154 50 50 6,100 9,600 660 L30-1113 8 11 6 8 108 50 80 3,000 7,500 141 L30-1213 16 21 6 8 108 50 80 5,100 7,500 289 L30-1413 24 28 6 8 154 50 80 6,300 9,600 410 L30-2113 16 11 6 11 108 50 50 3,200 7,500 230 L30-2213 32 21 6 11 108 50 50 5,300 7,500 470 L30-2413 48 28 6 11 154 50 50 6,100 9,600 660 Model Number Tiers / Bays Structure Exterior Dimensions (ft) Bay Dimensions (in) Single-Sided Access — Hinged Doors The hinged doors open full face, providing easy access to the stored drums. 8 9
  • 6. FM Approved Storage Cabinets IBC Totes 2-Hour Fire Rated – Drums / Totes These FM Approved Non-Combustible Storage Cabinets Are Specifically Designed and Sized for 350 Gallon IBC Totes FM Approved Single-Tiered 2-hour Fire Rated Models are Designed to Accommodate Drums and / or IBCs Capacities of 2 to 6 totes or 8 to 24 drums Storage capacities from 2 to 12 totes FM Approved Double-Tiered Fire Rated Models are Designed Specifically for Drums or IBCs, Storing 16-48 Drums or 4-12 IBC Totes These models provide the construction features listed at left but add a second tier for additional storage capacity Drums / totes rest on adjustable rack system, allowing storage flexibility Choose between models with hinged or sliding doors, both allow easy access to totes from outside the Cabinet Models are equipped with roll-up fire doors for ease of access to stored chemicals and added safety in case of fire Sump volumes meet EPA, NFPA, and FM requirements DENIOS-Leading Supplier of FM Approved Chemical Containment Products. Fire Rated designs up to 2-hour Single-tier design features one or two storage bays Low-viscous test ensures sumps are leak free Constructed of heavy gauge welded steel and FM approved 2-hour fire rated walls and doors Constructed of heavy gauge, welded steel frames and walls ump volumes meet EPA, NFPA, and FM S requirements vailable in single- and double-tiered A designs with up to four storage bays ow-viscous test ensures sumps are leak free L oll-up doors dimensions included in model box R DENIOS-Leading Supplier of FM Approved Chemical Containment Products. D rums / totes rest on adjustable rack system, allowing storage flexibility Double-tiered storage Cabinet with hinged doors for 4 IBCs. Single-Sided Access — Hinged Doors Capacity per Cabinet (IBCs) Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Length Depth Height Length Depth Sump Volume (gal) 50 80 3,000 10,500 371 Model Number L31-1111 2 11 5 9 108 L31-1311 3 15 5 9 154 50 80 3,400 14,575 529 L31-1211 4 21 5 9 108 50 80 5,100 10,500 L31-1411 6 28 5 9 154 50 80 6,300 L31-2111 4 11 5 13 108 50 61 L31-2311 6 15 5 13 154 50 L31-2211 8 21 5 13 108 L31-2411 12 28 5 13 154 Model Number Tiers / Bays Structure Exterior Dimensions (ft) Bay Dimensions (in) Roll-up fire doors allow Cabinets to remain open during work hours for easy access. A fuse link triggers the doors to close in the event of fire. FM approved Cabinets — Drums/IBCs, Roll-up Doors Capacity per Cabinet (Drums/IBCs) Length Depth Height Length Depth L32-1112 8/2 11 7 11 115 470 L32-1312 12/3 16 7 10 14,575 660 L32-1212 16/4 22 7 3,400 10,500 371 L32-1412 24/6 32 61 3,800 14,575 529 50 61 5,500 10,500 759 L32-2112 16 50 61 6,700 14,575 1,076 L32-2312 Load Capacity per Bay (lbs) Sump Volume (gal) 49 80 6,000 10,500 353 172 49 80 7,700 14,575 352 10 115 49 80 11,300 10,500 364 7 10 172 49 80 14,000 14,575 535 11 7 13 108 49 50 7,000 7,500 227 24 16 7 13 162 49 50 8,500 9,600 340 L32-2212 Single-Sided Access — Sliding Doors Height Shipping Weight (lbs) 32 22 7 13 108 49 50 12,500 7,500 479 L32-2412 48 32 7 13 162 49 50 15,000 9,600 706 Tiers / Bays Structure Exterior Dimensions (ft) Bay Dimensions (in) FM approved Cabinets — Drums, Roll-up Doors L31-1113 11 6 9 108 50 80 3,000 10,500 371 L31-1213 4 21 6 9 108 50 80 5,100 10,500 470 L31-1413 6 28 6 9 154 50 80 6,300 14,575 660 L33-2112 4 11 7 15 108 49 60 8,000 10,500 353 L31-2113 4 11 6 13 108 50 61 3,400 10,500 371 L33-2312 6 16 7 15 162 49 60 9,500 14,575 529 L31-2213 8 21 6 13 108 50 61 5,500 10,500 759 L33-2212 8 22 7 15 108 49 60 16,000 10,500 744 L31-2413 10 2 12 28 6 13 154 50 61 6,700 14,575 1,076 L33-2412 12 32 7 15 162 49 60 18,080 14,575 1,059 FM approved Cabinets — IBCs, Roll-up Doors 11
  • 7. Storage Cabinets for IBC Totes Single-Sided Access These Storage Cabinets have been specially designed for Intermediate Bulk Containers (IBCs). Sump of heavy gauge steel for extended life Sump welds are 100% inspected with a low-viscous test to insure leaktightness Removable grating for easy clean-up Extra strength, tubular steel construction Grounding package includes grounding lug, connection wire, and rod Sump volumes meet EPA  NFPA requirements The sump volume exceeds mandatory Federal Regulations. Coated with a durable, corrosion and weather resistant finish Full-face opening doors provide access to IBCs without the need to physically enter the structure. Single-tiered storage Cabinet with sliding doors (standard) for 3 IBC Totes saves facility space. Model in picture features optional fire rated design and fire suppression system. Addition of stands provides height to allow for spill-contained dispensing into small containers. Single-Sided Access — Hinged Doors Capacity per Cabinet (IBCs) Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Length Depth Height Length Depth Sump Volume (gal) L36-2115 2 11 5 9 120 50 80 2,100 10,500 388 L36-3102 3 14 5 9 154 50 84 2,500 14,575 388 L36-2125 4 11 5 12 120 50 60 2,900 10,500 388 L36-3105 6 14 5 12 154 50 60 3,400 14,575 388 L36-2503 4 21 5 9 120 50 80 4,200 10,500 388 L36-3142 6 27 5 9 154 50 84 5,400 14,575 465 L36-2515 8 21 5 12 120 50 60 5,600 10,500 388 L36-3145 12 27 5 12 154 50 60 6,800 14,575 465 Model Number Tiers / Bays Structure Exterior Dimensions (ft) Bay Dimensions (in) Single-Sided Access — Sliding Doors Added tier height and sump capacity makes tote Cabinets also appropriate for drum storage. 12 13
  • 8. Storage Cabinets for IBC Totes Double-Sided Access Double-sided Cabinets double storage capacity while not sacrificing immediate accessibility to the totes. Choose between sliding and roll-up door models. Designs provide up to three storage tiers. Coated with a durable, corrosion and weather resistant finish Sump of heavy gauge steel for extended life Grounding package includes grounding lug, connection wire, and rod When indoor placement of the Cabinet is between aisles or a sufficient pad area exists outdoors, double-sided Cabinets offer additional capacity without losing access to drums. Sump volumes meet EPA  NFPA requirements Sump welds are 100% inspected with a low-viscous test to insure leaktightness Removable grating for easy clean-up Extra strength, tubular steel construction Note: Due to their overall height, all triple-tiered units are produced and shipped in two sections. Assembly on site is easy using our complete, step-by-step instructions. DENIOS Cabinets are the most efficient and flexible chemical storage systems available. Multiple-tiered units provide secure, separate platforms for all pallets – no need to double-stack, greatly reducing material handling risks Move only the pallet(s) you need, eliminating any unnecessary double handling to three storage tiers. Up With double-sided access. Sump volumes meet EPA and other regulatory requirements Hinged or Sliding Door. Double-sided access designs keep all stored IBCs within easy access of the fork truck operator. Single-tiered storage Cabinet with sliding Doors for 6 IBCs. Single-tiered, double-sided Cabinet with fire suppression, a heated bay and roll-up doors (Custom engineered model, roll-up doors not standard). Double-Sided Access — Hinged Doors Capacity per Cabinet (IBCs) Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Length Depth Height Length Depth Sump Volume (gal) L36-2140 4 11 9 9 120 50 80 3,400 10,500 388 L36-3108 6 14 9 9 154 50 84 4,200 14,575 431 L36-2155 8 11 9 12 120 50 60 4,400 10,500 388 L36-3111 12 14 9 12 154 50 60 5,100 14,575 431 L36-2521 8 21 10 9 120 50 80 6,900 10,500 715 L36-3148 12 27 10 9 154 50 84 8,900 14,575 867 L36-2533 16 21 10 12 120 50 60 8,800 10,500 715 L36-3151 24 27 10 12 154 50 60 10,700 14,575 867 Model Number Tiers / Bays Structure Exterior Dimensions (ft) Bay Dimensions (in) Double-Sided Access — Sliding Doors Double-sided access increases capacity without decreasing accessibility. 14 15
  • 9. Storage Cabinets for Drums Single-Sided Access DENIOS has the most complete line of cabinets for storing drums and IBC’s. Full selection of options including: When facility floor space is at a premium, our triple-tier Cabinets can provide the most compact yet efficient storage system available. Each level is provided with its own grating platform for easy and secure pallet loading. 2- and 4-hour fire rated walls classified fire doors with automatic UL closing devices Cabinets provide highly efficient storage. All products can be accessed from outside the cabinet. No need to manhandle individual drums. Fire suppression systems Note: Due to their overall height, all triple-tiered units are produced and shipped in two sections. Assembly on site is easy using our complete, step-by-step instructions. Explosion-proof mechanical ventilation Let DENIOS help you select the best configuration for your facility: Fume or leak detection / alarm systems 2 or 3 pallet bay sizes 1 or 2 bay lengths 1, 2, or 3 tiers high Single- or double-sided access Spill sumps located in the base of each unit. Cabinets may be specially ordered with a variety of door styles: Double-tiered storage Cabinet with custom paint color and hinged doors holds 16 drums. Hinged Sliding Roll-up PVC curtain on application No doors (indoor placement) Double-tiered storage Cabinet with hinged doors holds 16 drums. Single-Sided Access — Hinged Doors Capacity per Cabinet (Drums) Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Length Depth Height Length Depth Sump Volume (gal) L16-3102 8 11 5 9 120 50 88 2,100 7,500 158 L39-3102 12 14 5 9 154 50 88 2,500 9,600 202 L16-3105 16 11 5 10 120 50 50 2,500 7,500 158 L39-3105 24 14 5 10 154 50 50 3,000 9,600 202 36 14 5 17 154 50 50 4,000 9,600 202 L16-3142 16 21 5 9 120 50 88 4,400 7,500 323 L39-3141 24 27 5 9 154 50 88 5,400 9,600 411 L16-3145 32 21 5 10 120 50 50 5,000 7,500 323 L39-3145 48 27 5 10 154 50 50 6,70 9,600 411 L39-3151 72 27 5 15 154 50 50 7,800 9,600 411 Model Number Tiers / Bays Structure Exterior Dimensions (ft) Bay Dimensions (in) Single-Sided Access — Roll-up Doors L39-3109 Single-Sided Access — Sliding Doors All Cabinet door styles provide easy access to stored drums or totes. 16 17
  • 10. Storage Cabinets for Drums Double-Sided Access Increase Capacity Without Sacrificing Accessibility DENIOS Cabinets are the most efficient and flexible chemical storage systems available. When indoor placement of the Cabinet is between aisles or a sufficient pad area exists outdoors, double-sided Cabinets offer additional capacity without losing access to drums. Multiple-tiered units provide secure, separate platforms for all pallets – no need to doublestack, greatly reducing material handling risks Sump volumes meet EPA and other regulatory requirements to three storage tiers. Up Note: Due to their overall height, all triple-tiered units are produced and shipped in two sections. Assembly on site is easy using our complete, step-by-step instructions. Passive ventilation prevents fume buildup With double-sided access. Grounding package included as standard equipment Sump of heavy gauge steel for extended life Hinged or Sliding Door. Sump welds are 100% inspected with a low-viscous test to insure leaktightness Move only the pallet(s) you need, eliminating any unnecessary double handling Sump volumes meet EPA  NFPA requirement Removable grating for easy clean-up Extra strength, tubular steel construction Coated with a durable, corrosion and weather resistant finish Double-tiered storage Cabinet with hinged doors on both sides, load capacity 48 drums. Grounding package includes grounding lug, connection wire, and rod Double-tiered storage Cabinet with sliding doors holds 96 drums. Double-Sided Access — Hinged Doors Capacity per Cabinet (Drums) Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Length Depth Height Length Depth Sump Volume (gal) L16-3122 16 11 9 9 120 50 88 3,600 7,500 297 L39-3121 24 14 9 9 154 50 88 4,200 9,600 381 L16-3125 32 11 9 10 120 50 50 4,100 7,500 297 L39-3125 48 14 9 10 154 50 50 4,800 9,600 381 72 14 9 17 154 50 50 6,200 9,600 431 L16-3162 32 21 9 9 120 50 88 7,300 7,500 600 L39-3161 48 27 10 9 154 50 88 8,900 9,600 767 L16-3165 64 21 9 10 120 50 50 8,400 7,500 600 L39-3164 96 27 10 10 154 50 50 12,400 9,600 767 L39-3167 144 27 10 15 154 50 50 12,500 9,600 867 Model Number Tiers / Bays Structure Exterior Dimensions (ft) Bay Dimensions (in) Single-Sided Access — Roll-up Doors L39-3130 Single-Sided Access — Sliding Doors Double-sided access, fire rated Cabinet fits well in existing aisle way of distribution hub; allowing interior storage of small containers of flammables. 18 19
  • 11. Basic Storage Cabinets T hese DENIOS Cabinet Designs Provide the Most Efficient and Economical Means to Store 55 Gallon Drums Standard Features: Material handling made easy! Choose between models with hinged, roll-up, or sliding doors- all providing easy access to stored drums entry required – easy-open roll-up doors No allow immediate access to all materials from outside the Cabinet Compliant spill sump captures leaks and spills Design keeps doors clear of forklift or other traffic and out of the wind Designs provide storage capacities for 8, 16, and 32 drums Standard Features Include: Compliant spill containment sumps in base Passive ventilation for fume control Rugged 11-gauge solid welded frame Rust inhibiting coated steel Locking mechanism for added security Wide door openings provide forklift access to palletized drums- no need for personnel to enter the Cabinet Welded steel tubular construction with 16 gauge walls stands up to most industrial environments Double-tier units save facility space. Roll-up door includes chain hoist for easy operation. Accommodates up to 4 pallets of drums. Cabinet easily stores 16 drums and features a space saving roll-up door. Basic Storage Cabinet — Drums, Hinged Doors Capacity per Cabinet (Drums) Length Depth Height Length Depth L20-1111 8 10 5 9 108 L20-2111 16 10 5 10 10 5 19 Model Number Tiers / Bays Structure Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Sump Volume (gal) 48 88 1,800 3,200 160 108 48 50 2,100 3,200 160 12 108 48 50 2,300 3,200 160 5 10 108 48 50 3,800 3,200 320 Exterior Dimensions (ft) Bay Dimensions (in) Basic Storage Cabinet — Drums, Roll-up Doors L20-1112 16 Basic Storage Cabinet — Drums, Sliding Doors L20-2213 32 Basic Storage Cabinet — Drums, Roll-up Doors L14-1005 8 11 5 9 120 50 69 2,100 7,500 158 L14-1030 12 14 5 9 154 50 69 2,500 9,600 202 L14-2005 16 11 5 10 120 50 50 2,600 7,500 158 L14-2030 24 14 5 10 154 50 50 3,000 9,600 202 Basic Storage Cabinet — IBCs, Roll-up Doors L14-8010 Model L20-2213 utilizes a sliding door for easy access and offers a 32 drum storage capacity 20 2 11 5 9 120 50 80 3,000 10,500 388 L14-8020 4 11 5 12 154 50 60 3,500 10,500 388 21
  • 12. Horizontal Storage Cabinets Custom Engineered Storage Cabinets Dispense Store Hazardous materials over a containment sump while providing spill compliance with Federal Regulations. Engineered Solutions for Your Unique Applications ully welded tubular frame construction F ouble- or triple-tiered models maximize D storage efficiency DENIOS Engineering leads the industry in the design and manufacture of customized enclosures designed for the safe storage of chemicals. Passive ventilation included Grounding package includes grounding lug, connector and rod 55-gallon drum dispensing station We provide solutions for the safe storage of: ump welds are 100% inspected with a S low-viscous test to insure leaktightness Double-tiered Cabinet out-fitted for horizontal placement of drums and with an optional vinyl curtain door. Single-Sided Access — Sliding Doors Capacity per Cabinet (Drums) Length Depth Height Length L16-3182 10 14 5 9 L16-3186 15 14 5 L16-3190 20 27 L16-3193 30 27 Model Number Tiers / Bays Structure Flammables or flammable / explosive processes Acids or caustic chemicals Temperature sensitive chemicals, whether for preservation heating / cooling or process heating / cooling Depth Tier Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Sump Volume (gal) 13 4 35 3,300 9,600 208 Contact Us: 10 13 4 29 3,400 9,600 208 5 9 26 4 35 6,100 9,600 417 5 10 26 4 29 6,300 9,600 417 For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l info2@denios-us.com Exterior Dimensions (ft) Bay Dimensions (ft) Heated and fire rated Cabinet also provides explosion relief panels for the storage of combustibles. Open Storage Systems Ideal for Indoor Storage of Non-Flammables and Non-Combustibles, where fumes and separation are not factors Constructed of heavy gauge steel for extended life Sump volumes meet or exceed EPA requirements Removable, galvanized steel grating Coated with a durable, corrosion resistant finish Greater sump volumes available upon request 4-bay / double-tiered storage system hold up to 48 drums. Single-Sided Access — Open Storage Capacity per Cabinet (Drums) Length Depth Height Length L12-3104 24 14 5 7 L12-3107 36 14 5 L12-3144 48 27 L12-3150 72 27 Model Number 22 Tiers / Bays Structure Depth Tier Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Sump Volume (gal) 13 4 — 2,900 9,600 202 12 13 4 — 3,400 9,600 202 5 7 26 4 — 5,700 9,600 411 5 12 26 4 — 6,300 9,600 411 Exterior Dimensions (ft) Bay Dimensions (ft) Heated Cabinet for processing stored chemicals. 23
  • 13. Fire Rated Storage Cabinets Choose from Cabinet designs for chemical storage or Buildings for housing chemicals and chemical processes. DENIOS Fire Rated Cabinets Primarily designed for the storage of flammable chemicals or products rovides for indoor or outdoor placement – P multiple storage tiers and single- or double-sided access to stored chemicals Great for distribution facilities with inventories of flammable products / chemicals. Cabinets can easily be placed in existing storage aisles – easing material handling and eliminating the need for costly reconstruction. Cabinet with self closing doors to keep fires outside of or limited to the inside of the enclosure Engineered Options for DENIOS Fire Rated Enclosures may include: approved firewalls, designs include 2UL and 4-hour rated construction Deflagration panels to redirect destructive forces in case of an explosion Fire, fume, or leak detection alarms or wet fire suppression systems Dry Ventilation systems to remove noxious or ignitable fumes Fire rated Buildings can house and segregate hazardous processes, like pumping, away from other facilities and personnel. Fire rated Cabinets allows for easy loading / unloading of stored drums, keeping personnel out of a poten­ tially hazardous environment. Cabinet shown has double-sided access utilizing fire rated roll-up doors. pill containment sumps which meet / S exceed EPA, UFC, NFPA, and OSHA regulations Heating / cooling options for temperature sensitive chemicals Special coatings and materials for the storage of acids, caustics, or corrosives Fire Rated designs up to 4-hour, heating systems for Freeze Protected 24 Fire rated roll-up doors close automatically in case of a fire in or outside of the cabinet. Fire rated, heated and cooled Cabinet also provides explosion proof lighting and temperature controls. 25
  • 14. Temperature Controlled Storage Cabinets Heating and Cooling Options for Preserving or Processing Chemicals Safe Solutions for Chemical Processing Contact Us: DENIOS Temperature Controlled Enclosures can be designed for preservation heating / cooling of temperature sensitive chemicals or provide higher temperatures for process heating Process heating / cooling of chemicals has inherent dangers. DENIOS enclosures address many of those risks through their standard construction and with many safety options. For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l info2@denios-us.com Designs provide thermostatically controlled steam, heat transfer fluid, or electrical heat and air cooling systems circulation / ventilation systems ensure Air proper heat / cooling distribution nclosures are constructed with fully E insulated, fire resistant walls and doors Typically employ hinged doors with perimeter gasketing and multi-point latching locks to maintain internal temperatures with all DENIOS enclosures, structures As feature an enclosed, compliant spill containment sump Fire rated Cabinet with cooling for oils / lubricants. 26 nsulated, 2-hour fire rated wall I construction (standard on all models) Explosion relief panels ver temperature controls / alarm systems O Explosion-proof mechanical exhaust ventilation n addition, all models are suitable for I outdoor placement, away from personnel and facilities achieve temperature ranges from Can 0°F to 300°F Industries served by DENIOS temperature controlled enclosures include: Foods and flavorings Pharmaceuticals Cosmetics Paint and ink manufacturing Chemicals Rubber and plastics Effective solutions for thermal processing of materials. Optimal solution for thermal treatment of large and small amounts of stored material igh capacity: up to 48 x 55 gallon drums H or 12 IBCs eat output and air circulation are perfectly H adjusted and are combined with uniform heat distribution to ensure a uniform temperature profile Heating Cabinets with electric heating and circulating air fan for optimal air circulation. Double-sided Cabinet used for processing heating / cooling of flavorings. 27
  • 15. Storage Cabinet Options Storage Cabinet Options Smoke / heat detectors fire alarms PE and stainless steel sump liners Heating For the protection of fire proof containers it is important that an early warning system is installed. DENIOS uses certified multi sensors for this purpose. Smoke and fire detection is quick and reliable and can be installed in conjunction with a siren. The alarm system can be connected to the main alarm system. DENIOS uses the most up-to-date temperature regulators to ensure user friendly programming of required temperatures. The majority of DENIOS regulators can be programmed and adjusted on the main control box on the exterior of the container. When storing acids, alkalis or other aggressive substances, it is recommended that sump liners be installed. These can be manufactured both in PE and stainless steel. Further information regarding sumps can be found in our main catalog. Many substances require optimal heating to maintain quality. DENIOS provides heating systems using electric or steam heat. Alarm lights System monitoring Grating Insulation In addition to audible alarms DENIOS can provide alarm lights to work in conjunction with the main alarm system, enhancing the warnings effectiveness to personnel. To monitor important features such as temperature, pressure, air quality etc., it is possible to install an assortment of sensors to the container. A continuous monitoring system can be installed to your specific requirement and standards. The system can be monitored in situ or attached to the main computer system which ensures a regular and safe way to monitor air flow etc. DENIOS fire proof containers are fitted with galvanized grating as standard. Alternative grating are available however and when storing aggressive substances, stainless steel grating or synthetic material grating can be provided. The walls of our HazMat insulated system containers guard against loss of energy, temperature and frost damage. DENIOS use different types of material ranging from a thickness of 60 to 125 mm. Sprinkler systems Gas detectors Grounding kits Cooling Sprinkler systems provide extra safety in containers used to store flammable and non-flammable substances. DENIOS offers several types of sprinkler systems. We can provide, standard, heavy foam, powder, Novec or CO2 systems. If poisonous gases are allowed to escape then early detection is a vital requirement. DENIOS can provide gas warning detectors where a pre-set level can be set and when reached an audible or visual alarm or both will occur. Grounding kits are required to avoid an electric discharge between the container and other conductive units. All DENIOS HazMat containers can be fitted with an accessory to avoid discharges. These are highly recommended for containers storing explosive materials. DENIOS engineering provide precise solutions to temperature control, such as cooling units and air conditioning systems. With DENIOS expertise we always have a solution for your needs. Fire dampers Leak Detector Special paint finishes Fire prevention air vents Where air circulation is required, fire dampers can be installed featuring automatic closing air vent mechanisms. These close automatically as soon as fire is detected, thus cutting off the supply of oxygen to the fire source in the container. 28 Temperature regulators Leak detectors can be installed in sumps to detect any leakage from container contents. The alarm can be audible, visual or both. Early detection allows prompt action to be taken. DENIOS offers internal as well as external multi color finishes. Where air circulation is required, fan-forced air vents can be installed featuring automatic closing air vent mechanisms. These close automatically as soon as fire is detected, thus cutting off the supply of oxygen to the fire source in the container. 29
  • 16. Introduction to Chemical Storage Buildings Secured and Store Hazardous Chemicals and Processes Away from Personnel / Facilities DENIOS Chemical Storage Building designs provide more storage flexibility, enhancing the efficiency of the structure over competitive models. Choose from over 25 standard sizes to provide the optimal space for storing your hazardous chemicals or processes. Sizes and Styles Popular Applications Available in 8, 10 and 12 foot widths with lengths from 8 to 52 feet Process enclosures: Pumping, mixing, dispensing, paint kitchen units are built to accommodate indoor All or outdoor placement. Door styles include hinged doors and roll-up doors and can be designed in multiple configurations Remote storage: Waste collection, fuel dispensing Non-Combustible, fire rated, and temperature controlled models available Designed for occupancy by personnel, DENIOS also provides numerous options to enhance safety, efficiency, and security in all our Buildings. DENIOS Chemical Storage Buildings carry FM Approval. Lifting eyes and forklift access allow for easy relocation Agricultural chemical storage: Parks and recreation, golf courses Secured storage and separation: Toxic, dangerous, valuable materials HazMat storage of drums handled by hand Applicable Regulations For your further reference DENIOS designs its HazMat storage buildings to be compliant with all recognized National Codes and generally accepted national standards. Hazardous materials storage is regulated by EPA at the federal level by the Code of Federal Regulations (40 CFR). In addition to federal and local regulations, risk management organizations such as Factory Mutual (FM Global) have developed their own standards. At the state and local level, Fire Codes such as IFC, UFC, NFPA 30 (Storage and Handling of Flammable Liquids), Building Codes (UBC IBC) and other requirements specific to State and Local jurisdictions may also apply. Most DENIOS HazMat storage buildings for outdoor placement can be shipped bearing the FM approval label. component enclosures Fuel Battery testing enclosures 8, 10, and 12 foot depths allow for addition of shelving for smaller containers / tools Constructed of an 11 gauge tubular frame with 16 gauge steel walls DENIOS-Leading Supplier of FM Approved Chemical Containment Products. Fire Rated designs up to 4-hour, heating systems for Freeze Protected Typical local code issues include: wind load, snow load, seismic zone, fire rating and separation of flammable storage from the nearest building. Due to local code variance and different enforcement philosophies, DENIOS always recommends checking with the local Authority Having Jurisdiction to verify that a specific configuration will comply with local codes. Choose for multiple door sets Building with optional shelving and door sets for oils and lubricants storage and processing 30 16 x 8 storage Building can be engineered for the storage of chemicals or housing of chemical processes. DENIOS Building designs include 2- and 4-hour fire rated construction. Compliant spill containment sump sits below galvanized grating Designed for occupancy by personnel Perfect for storing and handling unpalleted drums and housing hazardous processes This 28 x 8 storage Building holds up to 39 drums. Seen here with optional door sets and integrated shelving package. 31
  • 17. Premium Storage Buildings – 8‘ Depth The Solution to Securing and Storing Hazardous Chemicals and Processes Walk-In / Occupancy Enclosed Storage Buildings are ideal for storing drums and smaller containers when frequent access is required to store, mix or dispense. Once inside, you are able to work with the materials over an internal spill sump. can be fire rated, insulated, heated or cooled as individual requirements dictate. Sump volumes which exceed EPA, UFC, NFPA, and OSHA regulations Numerous sizes and options to match your specific requirements. Grounding package includes grounding lugs, connector and rod Corrosion and weather resistant finish Relocatable via forklift or crane Removable, galvanized steel grating for easy clean-up of spills Maximize your storage capabilities! Add shelving around the perimeter of the Walk-In Building to store small containers along with your 55-gallon drums. Standard designs feature a single leaf door; buildings can be constructed with more door sets if required DENIOS-Leading Supplier of FM Approved Chemical Containment Products. Shelving may be added to store small containers Ramps are available for manual drum loading FM Approved Doors provided with inside release features These Premium non-combustible structures feature solidly welded frame construction and Contact Us: For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l info2@denios-us.com Provides storage for up to 9 drums. Customized Building provides added height and storage for up to 12 drums. Standard model is L53-1008. This 40 x 8 Building holds up to 57 drums. Seen here with optional lighting and heating package. Buildings — 8’ Depth Model Number L53-0808-FM L53-1008-FM L53-1208-FM L53-1408-FM L53-1608-FM L53-1808-FM L53-2008-FM L53-2208-FM L53-2408-FM L53-2608-FM L53-2808-FM L53-3008-FM L53-3208-FM L53-3408-FM L53-3608-FM L53-3808-FM L53-4008-FM L53-4208-FM L53-4408-FM L53-4608-FM L53-4808-FM L53-5008-FM L53-5208-FM Standard 10 x 8 Building with optional crane for material handling. 32 Drum Cap 9 12 15 18 21 24 27 30 33 36 39 42 45 48 51 54 57 60 63 66 69 72 75 Length Depth Height Length Depth Height Shipping Weight (lbs) 94 118 142 166 190 214 238 262 286 310 334 358 382 406 430 454 478 502 526 550 574 598 622 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 89 113 137 161 185 209 233 257 281 305 329 353 377 401 425 449 473 497 521 545 569 593 617 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 2900 3900 3900 4300 4800 5300 5800 6300 6800 7300 7700 8200 8700 9200 9700 10200 10700 11100 11600 12100 12600 13100 13600 Exterior Dimensions (ft) Bay Dimensions (in) Load Capacity per Bay (lbs) Sump Volume (gal) 19036 24169 29303 34436 39569 44703 49836 54969 60103 65236 70369 75503 80636 85769 90903 96036 101169 106303 111436 116569 121703 126836 131969 205 260 315 370 425 480 536 591 646 701 756 811 867 922 977 1032 1087 1142 1198 1253 1308 1363 1418 Interior dimensions shown are for non-combustible units. Fire rated designs differ, please contact factory for details. 33
  • 18. Premium Storage Buildings – 10‘ Depth Typical Applications: Storage of multiple, manually handled drums and small containers Housing and enclosing of hazardous processes such as pumping, mixing, and dispensing Secured, isolated storage of toxic or dangerous chemicals Satellite supply storage for fuels or lubricants. Waste collection and sorting 40 x 10 Building holds up to 76 drums. Shown here with lighting and fan forced heating system. Gain additional sidewall space with our 10-foot nominal depth Buildings DENIOS-Leading Supplier of FM Approved Chemical Containment Products. Added space great for shelves holding smaller containers Provides more room for personnel to maneuver with mixing or dispensing applications 34 10 x 10 fire rated Building, optional ramp eases material handling in and out of the building. Buildings — 10’ Depth Model Number Ramps available to ease drum handling in and out of the Building 16 x 10 Building holds up to 28 drums. Shown here with optional door set. 10 x 10 Building with options including alarm, fire suppression system, and mechanical ventilation. 20 x 10 non-combustible Building with added ramp. Drum Cap L53-1010-FM L53-1210-FM L53-1410-FM L53-1610-FM L53-1810-FM L53-2010-FM L53-2210-FM L53-2410-FM L53-2610-FM L53-2810-FM L53-3010-FM L53-3210-FM L53-3410-FM L53-3610-FM L53-3810-FM L53-4010-FM L53-4210-FM L53-4410-FM L53-4610-FM L53-4810-FM L53-5010-FM L53-5210-FM 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80 84 88 92 96 100 Length Depth Height Length Depth Height Shipping Weight (lbs) 118 142 166 190 214 238 262 286 310 334 358 382 406 430 454 478 502 526 550 574 598 622 118 142 166 190 214 238 262 286 310 334 358 382 406 430 454 478 502 526 550 574 598 622 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 113 137 161 185 209 233 257 281 305 329 353 377 401 425 449 473 497 521 545 569 593 617 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 4500 4500 5000 5600 6100 6700 7200 7800 8300 8900 9400 10000 10500 11000 11600 12100 12700 13200 13800 14300 14900 15400 Exterior Dimensions (ft) Bay Dimensions (in) Load Capacity per Bay (lbs) Sump Volume (gal) 30761 37294 43828 50361 56894 63428 69961 76494 83028 89561 96094 102628 109161 115694 122228 128761 135294 141828 148361 154894 161428 167961 330 400 470 541 611 681 751 821 891 961 1031 1102 1172 1242 1312 1382 1452 1522 1593 1663 1733 1803 Interior dimensions shown are for non-combustible units. Fire rated designs differ, please contact factory for details. 35
  • 19. Premium Storage Buildings – 12‘ Depth Typical Applications: Extra deep 12-foot buildings provide floor and wall space for storage and process activities Flammable storage where drums must be handled individually dded depth provides optimum storage A and processing flexibility emote storage of regulated chemicals R such as pesticides and other toxic or hazardous materials ultiple door sets available for ease of M handling and access re-fabricated process enclosures to P provide separation of dangerous activities from other work areas Interior walls can be added to separate processes or stored chemicals ollection and temporary storage of wastes C Numerous options available for all buildings, including 2- and 4-hour fire rated construction Designs provide forklift access and lifting eyes for easy relocation DENIOS-Leading Supplier of FM Approved Chemical Containment Products. 24 x 12 processing Building with XP lighting, alarm and heating package. Shown with optional door set. 12 x 12 with fire rated construction and electrical package. Added depth of 12 foot Buildings accommodates the addition of shelving systems. Buildings — 12’ Depth Model Number L53-1212-FM L53-1412-FM L53-1612-FM L53-1812-FM L53-2012-FM L53-2212-FM L53-2412-FM L53-2612-FM L53-2812-FM L53-3012-FM L53-3212-FM L53-3412-FM L53-3612-FM L53-3812-FM L53-4012-FM L53-4212-FM L53-4412-FM L53-4612-FM L53-4812-FM L53-5012-FM L53-5212-FM Contact Us: For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l info2@denios-us.com 12 x 12 Building with 144 square feet holds up to 25 drums. Shown with optional fire rated package. 36 Drum Cap 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 Length Depth Height Length Depth Height Shipping Weight (lbs) 142 166 190 214 238 262 286 310 334 358 382 406 430 454 478 502 526 550 574 598 622 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 137 161 185 209 233 257 281 305 329 353 377 401 425 449 473 497 521 545 569 593 617 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 5100 5700 6300 6900 7500 8100 8700 9400 10000 10600 11200 11800 12400 13000 13600 14200 14900 15500 16100 16700 17300 Exterior Dimensions (ft) Bay Dimensions (in) Load Capacity per Bay (lbs) Sump Volume (gal) 43288 50872 58455 66038 73622 81205 88788 96372 103955 111538 119122 126705 134288 141872 149455 157038 164622 172205 179788 187372 194955 464 546 627 708 790 871 952 1034 1115 1197 1278 1359 1441 1522 1603 1685 1766 1847 1929 2010 2091 Interior dimensions shown are for non-combustible units. Fire rated designs differ, please contact factory for details. 37
  • 20. Custom Engineered Storage Buildings Engineered Solutions For Your Unique Applications Buildings for housing hazardous processes – Process Buildings DENIOS Engineering leads the industry in the design and manufacture of customized enclosures designed for the safe storage of chemicals. With the addition of standard and custom options and engineered construction, DENIOS Buildings are frequently utilized to house hazardous processes like pumping, mixing, heating, and dispensing. Designs include 2- and 4-hour fire rated construction as well as damage limited wall panels. We provide solutions for the safe storage of: Flammables or flammable / explosive processes Acids or caustic chemicals Process Applications include: Paint kitchens Pumping operations Battery testing enclosures component enclosures Fuel DENIOS Engineering provides you: complete understanding of hazardous A chemicals and chemical processes Expert knowledge of regulations and fire codes technical sales staff and engineering A department working with you every step of the way in designing a safe storage solution for your unique application Temperature sensitive chemicals, whether for preservation heating / cooling or process heating / cooling ompletely customized enclosures provide C added access for personnel, material handling equipment, or the incorporation of the structure into your existing processes or facilities Fire rated Building with custom door set to improve access. Customized chemical storage Building engineered to accommodate and function with customer processing equipment. This engineered building for the storage and processing of acids includes personnel showers, material handling crane, manway door and fiberglass grating (above and right). 38 Customized oil storage unit provides access to drums via forklift as well as a manway. Buildings allow for remote placement, while still providing ample work space for periodic occupancy of personnel. 39
  • 21. Fire Rated Storage Buildings Customized Chemical Storage and Processing Solutions Provide the Added Security of Fire Rated Construction Engineered Options for DENIOS Fire rated Enclosures may include: approved firewalls, designs include UL 2- and 4-hour rated construction DENIOS Engineering leads the industry in the design and manufacture of customized enclosures designed for the safe storage of chemicals. Deflagration panels to redirect destructive forces in case of an explosion DENIOS Fire Rated Buildings Fire, fume, or leak detection alarms Primarily used for the storage flammable chemicals or processes or wet fire suppression systems Dry Ventilation systems to remove noxious or ignitable fumes Provide pre-engineered rooms separating flammable chemicals and/or processes such as pumping, dispensing, or mixing Designs allow for indoor or outdoor placement Interior walls can be added to separate dangerous chemicals from processes Spill containment sumps which meet / exceed EPA, UFC, NFPA, and OSHA regulations Building provides fire suppression, explosion proof lights and mechanical ventilation. Heating / cooling options for temperature sensitive chemicals Special coatings and materials for the storage of acids, caustics, or corrosives DENIOS Engineering provides you: Customized chemical storage Building with optional door location, fire rated construction, and heating system. complete understanding of hazardous A chemicals and chemical processes xpert knowledge of regulations and fire codes E technical sales staff and engineering A department working with you every step of the way in designing a safe storage solution for your unique application Contact Us: For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l info2@denios-us.com Typical fire suppression systems feature dry chem extinguishers. Fire alarms, fume and leak detector systems are also available. 40 Fire rated building without spill containment sump for the housing of power generators. Fire rated Building with added door measures 30 x 10 and has a 56 drum storage capacity. 41
  • 22. Temperature Controlled Storage Buildings DENIOS Temperature Controlled Enclosures can be Designed for Preservation Heating / Cooling of Temperature Sensitive Chemicals or Provide Higher Temperatures for Process Heating. For the Safe Processing or Preservation Heating / Cooling of Chemicals Designed and Manufactured for Safe Chemical Processing Process heating / cooling of chemicals has inherent dangers. DENIOS enclosures address many of those risks through their standard construction and with many safety options. Process or preservation cooling and heating (steam or electrical). Cool to 0°F, heat to 300°F circulation / ventilation systems ensure Air proper heat / cooling distribution nclosures are constructed with fully E insulated, fire resistant walls and doors Typically employ hinged doors with perimeter gasketing and multi-point latching locks to maintain internal temperatures with all DENIOS enclosures, structures As feature an enclosed, compliant spill containment sump nsulated, 2-hour fire rated wall construction I (standard on all models) Explosion relief panels Contact Us: For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l info2@denios-us.com Heated and cooled storage Building with fire suppression system, fire rated construction, and explosion-relief panels designed to house automotive paint pumping equipment. 42 ver temperature controls / alarm systems O Explosion-proof mechanical exhaust ventilation addition, all models are suitable for outdoor In placement, away from personnel and facilities rated construction and fire Fire suppression systems. May include self-closing roll-up fire doors Chemical leak and fume detectors / alarms circulation / removal systems Air lighting and electrical for XP hazardous areas / applications Manual and automatic cranes for material handling mph / hurricane rated construction 150 Interior of Building shows electric heating unit, explosion proof light, and XP controls. Custom Building provides heating/cooling, explosion-proof lighting, and explosion relief panels for the storage and processing of combustibles. 43
  • 23. Storage Cabinet Options Storage Building Options Smoke / heat detectors fire alarms PE and stainless steel sump liners Heating For the protection of fire proof containers it is important that an early warning system is installed. DENIOS uses certified multi sensors for this purpose. Smoke and fire detection is quick and reliable and can be installed in conjunction with a siren. The alarm system can be connected to the main alarm system. DENIOS uses the most up-to-date temperature regulators to ensure user friendly programming of required temperatures. The majority of DENIOS regulators can be programmed and adjusted on the main control box on the exterior of the container. When storing acids, alkalis or other aggressive substances, it is recommended that sump liners be installed. These can be manufactured both in PE and stainless steel. Further information regarding sumps can be found in our main catalog. Many substances require optimal heating to maintain quality. DENIOS provides heating systems using electric or steam heat. Alarm lights System monitoring Grating Insulation In addition to audible alarms DENIOS can provide alarm lights to work in conjunction with the main alarm system, enhancing the warnings effectiveness to personnel. To monitor important features such as temperature, pressure, air quality etc., it is possible to install an assortment of sensors to the container. A continuous monitoring system can be installed to your specific requirement and standards. The system can be monitored in situ or attached to the main computer system which ensures a regular and safe way to monitor air flow etc. DENIOS fire proof containers are fitted with galvanized grating as standard. Alternative grating are available however and when storing aggressive substances, stainless steel grating or synthetic material grating can be provided. The walls of our HazMat insulated system containers guard against loss of energy, temperature and frost damage. DENIOS use different types of material ranging from a thickness of 60 to 125 mm. Sprinkler systems Gas detectors Grounding kits Cooling Sprinkler systems provide extra safety in containers used to store flammable and non-flammable substances. DENIOS offers several types of sprinkler systems. We can provide, standard, heavy foam, powder, Novec or CO2 systems. If poisonous gases are allowed to escape then early detection is a vital requirement. DENIOS can provide gas warning detectors where a pre-set level can be set and when reached an audible or visual alarm or both will occur. Grounding kits are required to avoid an electric discharge between the container and other conductive units. All DENIOS HazMat containers can be fitted with an accessory to avoid discharges. These are highly recommended for containers storing explosive materials. DENIOS engineering provide precise solutions to temperature control, such as cooling units and air conditioning systems. With DENIOS expertise we always have a solution for your needs. Fire dampers Leak Detector Special paint finishes Fire prevention air vents Where air circulation is required, fire dampers can be installed featuring automatic closing air vent mechanisms. These close automatically as soon as fire is detected, thus cutting off the supply of oxygen to the fire source in the container. 44 Temperature regulators Leak detectors can be installed in sumps to detect any leakage from container contents. The alarm can be audible, visual or both. Early detection allows prompt action to be taken. DENIOS offers internal as well as external multi color finishes. Where air circulation is required, fan-forced air vents can be installed featuring automatic closing air vent mechanisms. These close automatically as soon as fire is detected, thus cutting off the supply of oxygen to the fire source in the container. 45
  • 24. Introduction to Chemical Storage Lockers The Preferred Solution for Secured, Small Volume Storage of Drums and Totes Constructed with 16 gauge steel walls Added height allows for attachment of pumps to vertical drums and shelving Perfect for storing and handling small quantities of drums / IBC totes Common Applications for Lockers Outdoor storage of small volumes of hazardous chemicals Rail, marine, truck, and DOT terminals, storing / dispensing lubricants and oils DENIOS’ provides business and industry the most complete drum Locker program available. Designed for small volume outdoor storage of drums and IBC Totes, DENIOS’ Locker Program manufactures a variety of models; from secured, basic storage of non-combustible chemicals to more robust designs for hazardous applications, including 2-hour fire rated construction. Parks, turf, and nursery centers for storage of fertilizers and pesticides Temperature controlled outdoor storage of raw materials Hazardous waste accumulation centers The majority of DENIOS Lockers are FM Approved- see individual pages for details. Applicable Regulations For your further reference DENIOS Lockers meet the federal requirements for spill containment of hazardous liquids as regulated by the EPA (40 CFR). Hazardous materials storage is regulated by EPA at the federal level by the Code of Federal Regulations (40 CFR). DENIOS follows NFPA 30 regulations for specification compliance for outdoor placement. At the state and local level, Fire Codes such as IFC, UFC, NFPA 30 (Storage and Handling of Flammable Liquids), Building Codes (UBC IBC) and other requirements specific to State and Local jurisdictions may also apply. Most Locker designs are FM Approved and / or are constructed with UL approved walls / doors. Due to local code variance and different enforcement philosophies, DENIOS always recommends checking with the local Authority Having Jurisdiction to verify that a specific configuration will comply with local codes. Although DENIOS provides numerous standard designs, we also custom engineer Lockers to meet customer requirement. Sizes and Styles: Locker capacities from 2-14 drums, 1-2 IBC totes units are built to accommodate outdoor All placement. Door styles vary and include hinged doors and roll-up doors Locker and door heights allow added headroom for attachment of mixers or pumps for dispensing / processing Typical local code issues include: wind load, snow load, seismic zone, fire rating and separation of flammable storage from the nearest building. Compliant spill containment sump sits below galvanized grating on-Combustible, fire rated, and / or N temperature controlled models available Optional ramp eases loading and unloading of non-palleted drums Channels for forklift access allow for easy relocation Full-face opening doors ease material handling in and out of the Locker 4 drum storage Locker. Design provides added headroom for optional shelving or attaching pumps to drums. Locker Program ­ Overview – K-Series Lockers PK-Series Lockers N-Series Lockers IBC Tote Lockers Specialty Lockers These light duty, economy Lockers provide for 1, 2, and 4 drum capacities. Non- combustible and 2-hour fire rated construction models handle 2, 4, 6, and Great for secured storage of non-hazardous chemicals. 8 drum capacities. Non-combustible models FM Approved. Our most complete Drum Locker series, features non-combustible, damage limiting, and 2-hour fire rated construction models, Non-combustible, 2-hour fire rated, and special dispensing models highlight these 1-2 tote capacity designs. Numerous options also available. 2-hour, fire rated construction with automatic closing roll-up doors. 2 to 8 drum capacities. Fire rated Locker modified to have two levels. Used to store small volume containers of flammables. 2-14 drum capacities, and numerous options. FM Approved. 90 and 150 MPH rated designs. 46 Most models FM Approved and provide 90 and 150 MPH rated designs. FM Approved. 90 and 150 MPH rated designs. International Fire Code (IFC) International Building Code (IBC) 2-hour Fire Rated IBC Locker with roll-up door. Door includes fuse link and will automatically close in case of fire. Code of Federal Regulations (CFR) Environmental Protection Act (EPA) Fire Rated designs up to 2-hour, heating systems for Freeze Protected National Fire Protection Assn. (NFPA) Uniform Fire Code (UFC) Uniform Building Code (UBC) 47
  • 25. K-Series Storage Lockers Shelf Package Our Solid, light duty Locker Shelf System for our K-Series Lockers Design provides additional interior height, allowing for vertical drum pumping operations. Self-supporting shelf system rests on grating and provides efficiency and convenience when storing smaller containers Provides secured, weather-proof exterior storage. Available in 1, 2, 4, and 8 drum models Painted steel frame supports heavy duty galvanized shelves Steel construction provides strength and durability System designed to fit one, two, and four drum models gallon sump meets EPA 66 and UFC requirements Each shelf provides a load capacity of 150 lbs (one drum model) and 200 lbs (2 and 4 drum models) Walls and doors constructed of 20 gauge steel Standard system includes shelf stand and one shelf. Additional shelves available Four way forklift access makes relocation easy be easily removed intact should Can storage requirements change ockable hinged door provides added L security and opens wide for easy access to drums / containers 59” interior height allows easy access to drum tops for dispensing. Designs provide for the storage of 1, 2, 4, and 8 drums. Full-faced, lockable hinged door provides security and weather protection. Vents for passive ventilation are standard. K-Series Lockers — Shelf Package Bottom supports rest directly on grating. Galvanized shelves and uprights make adjustments easy while providing strength to hold up to 200 lbs. K-Series Lockers — Shelf Package Model Number Drum Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length K17-3851 K17-3852 K17-3854 K17-3856 48 Optional shelving allows for the efficient storage of small containers and tools. Ships knock-down; easily bolts together 1/1 2/1 4/1 8/2 33 58 58 116 33 33 58 58 82 76 73 73 30 50 55 110 30 30 55 55 59 59 59 59 28 54 28 64 Exterior Dimensions (ft) Bay Dimensions (in) Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Sump Volume (gal) Model Number Drum Package 61 61 61 61 462 616 882 1762 600 1,200 2,400 4,800 66 66 66 140 K17-3858 K17-3859 K17-3860 K17-3861 1 Drum 1 Drum Shelf Adder 2+4 Drum 2+4 Drum Shelf Adder Door Opening (in) Length Depth Height Shipping Weight (lbs) 31 30 51 51 25 18 25 18 55 55 - 60 15 80 23 Dimensions (in) Load Capacity (lbs) 150 150 200 200 Self supporting system provides stability without having to drill into the Locker. Contact Us: For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l info2@denios-us.com 49
  • 26. PK-Series Storage Lockers Non-Combustible 2-Hour Fire Rated Our PK-Series Lockers feature a heavy duty, 11 gauge welded steel construction. Capacities include 2, 4, 6, and 8 drum models. Non-combustible designs are FM Approved. Our “PK” line of Lockers also are available in 2-hour fire rated construction, allowing for convenient, secured outdoor storage of flammables near your facility. onstructed with UL – approved 2-hour C rated firewall design interior headroom allows 72” accessing vertically placed drums for pumping / dispensing Easily removable, galvanized steel grating Complies with fire rating requirements for storage of flammables within 10 feet of your facility Sump volumes meet EPA and UFC requirements Drums can be easily accessed with a fork truck or optional ramp Lockable hinged doors with inside release multiple Lockers to separate Use incompatible materials shelving for smaller containers Add 4 drum fire rated Locker provides secure, weather-tight enclosure for outdoor dispensing. Secure, Enclosed Outdoor Storage of Flammables with 71” Interior Headroom for Dispensing Equipment. Passive ventilation Exterior grounding lug Anchoring point Locker height allows for shelving, depth (4-drum models and up) provides space for horizontal placement of drums. NFPA 704 placard Choose between blue, tan, or white painted finish Available options: Ramp Interior light (300W) with fan (350 CFM) Exterior light (500W) with photo eye Shelves Fire Bottle (FE-241) Note: Two 13” vent hoods ship unattached but are included in length dimension. 4 drum storage Locker. Extra headroom for optional shelving or attaching pumps to drums. All Lockers have wide, full-face opening doors for easy access and pallet loading. Note: Two 13” vent hoods ship unattached but are included in length dimension. DENIOS-Leading Supplier of FM Approved Chemical Containment Products. PK-Series Lockers — Non-Combustible Model Number Drum Capacity per Cabinet K17-3571 K17-3575 K17-3578 K17-3580 2 4 6 8 50 6-drum fire rated Locker utilizing optional shelving package for storage of smaller containers. Price of shelving not included. PK -Series Lockers — 2-Hour Fire Rated Length Depth Height Length Depth Height Length Height Shipping Weight (lbs) 96 96 118 143 58 70 70 70 88 88 88 88 66 66 88 113 49 62 62 62 72 72 72 72 51 51 73 98 71 71 71 71 1,700 1,900 2,300 2,700 Exterior Dimensions (ft) Bay Dimensions (in) Door Opening (in) Load Capacity per Bay (lbs) Sump Volume (gal) Model Number Drum Capacity per Cabinet 600 1,200 2,400 4,800 102 127 168 228 P19-1000 P19-1050 P19-1100 P19-1150 2 4 6 8 Length Depth Height Length Depth Height Length Height Shipping Weight (lbs) 96 96 118 143 58 70 70 70 88 88 88 88 55 55 77 102 44 56 56 56 71 71 71 71 51 51 73.25 98 71 71 71.5 71 1,700 1,900 2,300 2,700 Exterior Dimensions (ft) Bay Dimensions (in) Door Opening (in) Load Capacity per Bay (lbs) Sump Volume (gal) 600 1,200 2,400 4,800 65 97 135 178 51
  • 27. N-Series Storage Lockers Non-Combustible 2-Hour Fire Rated The DENIOS Non-Combustible N-Series Locker Line provides a wide range of storage capacities (2-14 drums) with numerous options. All models come standard with: Our fire rated N-Series Lockers provide 2-hour fire rated construction with a variety of options and capacities of 2-14 drums. - Galvanized grating above a spill compliant sump - Passive ventilation - Exterior grounding lug - Anchoring point - NFPA 704 placard - Choose between blue, tan, or white painted finish Durable 11-gauge welded, steel construction Provides a spill compliant sump, meeting EPA and UFC requirements FM approved Lockable, hinged doors with inside release provides added safety Constructed with UL- approved 2-hour rated firewall design rovides a spill compliant sump, meeting P EPA and UFC requirements omplies with fire rating requirements C for storage of flammables within 10 feet of your facility FM approved Lockable, hinged doors with inside release provides added safety Options include: - Ramp and Shelves - Water Sprinkler - Fire Bottle (FE-241) - ry Chemical fire suppression system D - 1.8kw and 3.6kw electric heater with R-10 insulation - 14,000 BTU air conditioner with R-10 insulation - Interior light (300W) with fan (350 CFM) - Exterior light (500W) with photo eye - Fiberglass grating and poly sump liner for storing acids / caustics DENIOS-Leading Supplier of FM Approved Chemical Containment Products. N-Series Lockers come in Lockers for 2-14 Drum, Non-Combustible Storage Locker. 14 drum, 2-hour fire rated design features three door sets to ease material handling. Ramp for N-Series Lockers secures to door sill without effecting door performance. Note: wo 13” vent hoods ship unattached T but are included in length dimension. Lockers for 2-14 drum, 2-hour fire rated design is constructed with UL Approved firewalls. 90 MPH and 150 MPH Hurricane Rated Designs. N-Series / Non-Combustible — 90 mph Construction N-Series / 2-Hour Fire Rated — 90 mph Construction Model Number Drum Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length N05-3004 N05-3009 N05-3015 N05-3020 N05-3030 N05-3035 N05-3040 2/1 4/1 6/1 8/1 10 / 2 12 / 2 14 / 3 96 96 118 143 168 193 236 58 70 70 70 70 70 70 98 98 98 98 98 98 98 66 66 88 113 138 163 206 50 62 62 62 62 62 62 82 82 82 82 82 82 82 54 54 54 54 54 54 54 Exterior Dimensions (ft) Bay Dimensions (in) Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Sump Volume (gal) Model Number Drum Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length 80 80 80 80 80 80 80 1,400 1,600 2,400 2,600 3,300 3,500 4,900 1,200 2,400 3,600 4,800 6,000 7,200 8,400 103 128 170 218 267 315 398 N05-4004 N05-4009 N05-4015 N05-4020 N05-4030 N05-4035 N05-4040 2/1 4/1 6/1 8/1 10 / 2 12 / 2 14 / 3 96 96 118 143 168 193 236 58 70 71 71 71 71 71 98 98 98 98 98 98 98 56 56 77 102 127 152 195 42 52 52 52 52 52 52 81 81 81 81 81 81 81 52 52 52 52 52 52 52 Door Opening (in) N-Series / Non-Combustible — 150 mph Construction Bay Dimensions (in) Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Sump Volume (gal) 79 79 79 79 79 79 79 3,000 3,400 4,000 4,800 5,600 6,400 7,900 1,200 2,400 3,600 4,800 6,000 7,200 8,400 77 99 125 165 205 245 315 Load Capacity per Bay (lbs) Sump Volume (gal) 1,200 2,400 3,600 4,800 6,000 7,200 8,400 77 99 124 165 205 245 315 Door Opening (in) N-Series / 2-Hour Fire Rated — 150 mph Construction Model Number Drum Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length N05-3104 N05-3109 N05-3115 N05-3120 N05-3130 N05-3135 N05-3140 2/1 4/1 6/1 8/1 10 / 2 12 / 2 14 / 3 96 96 118 143 168 193 236 58 70 70 70 70 70 70 98 98 98 98 98 98 98 61 64 86 111 136 161 204 49 61 61 61 61 61 61 82 82 82 82 82 82 82 54 54 54 54 54 54 54 52 Exterior Dimensions (ft) Exterior Dimensions (ft) Bay Dimensions (in) Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Sump Volume (gal) Model Number Drum Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length Height Shipping Weight (lbs) 80 80 80 80 80 80 80 1,700 1,900 2,400 2,900 3,400 3,800 5,100 1,200 2,400 3,600 4,800 6,000 7,200 8,400 96 121 162 209 256 304 388 N05-4104 N05-4109 N05-4115 N05-4120 N05-4130 N05-4135 N05-4140 2/1 4/1 6/1 8/1 10 / 2 12 / 2 14 / 3 96 96 118 143 168 193 236 58 70 71 71 71 71 71 98 98 98 98 98 98 98 54 54 75 100 125 150 193 41 50 50 50 50 50 50 81 81 81 81 81 81 81 52 52 52 52 52 52 52 79 79 79 79 79 79 79 3,000 3,400 4,000 4,800 5,600 6,400 7,900 Door Opening (in) Exterior Dimensions (ft) Bay Dimensions (in) Door Opening (in) 53
  • 28. N-Series Storage Lockers IBC Storage Lockers Explosion Relief Panels Non-Combustible These N-Series Lockers feature explosion relief panels built into the rear of each Locker- diverting destructive forces away from personnel and facilities in the event of an ignition / explosion of the stored drums. N on-Combustible Designs provide secure, spill contained storage for 1-2 IBC Totes. Provides a spill compliant sump, meeting EPA and UFC requirements Designs are FM approved Durable 11-gauge welded, steel construction Lockable hinged doors provide full face opening, easing material handling in and out of the Locker Provides a spill compliant sump, meeting EPA and UFC requirements FM approved Full-face opening eases access for material handling Lockable, hinged doors with inside release provides added safety uilt to carry higher loads from IBCs B 2-hour fire rated models also available. Contact factory for details Models P19-2250 and P19-2255 include damage limiting construction (DLC) panels ll models come standard with: A ptions include: O - alvanized grating above a spill G compliant sump - Passive ventilation - Exterior grounding lug - Anchoring point - NFPA 704 placard - hoose between blue, tan, or white C painted finish Rear panels provide an exit for explosive force- diverting the blast’s destructive force away from personnel / facilities. IBC tote Locker - ry chemical fire suppression system D - .8 or 3.6 kw electric heater with 1 R-10 insulation - 4,000 BTU air conditioner with 1 R-10 insulation - Exterior light (500 W) with photo eye - iberglass grating and poly sump F liner for storing acids / caustics Note: wo 13” vent hoods ship unattached T but are included in length dimension. DENIOS-Leading Supplier of FM Approved Chemical Containment Products. DENIOS-Leading Supplier of FM Approved Chemical Containment Products. N-Series Lockers come in 90 MPH and 150 MPH N-Series Lockers come in 90 MPH and 150 MPH Hurricane Rated Designs. In case of an explosion, relief panel detaches from the Locker, diverting destructive forces away, protecting the integrity of the Locker and preventing any explosion caused shrapnel. Safety cables prevent relief panels from causing damage. IBC Lockers / Non-Combustible — 90 mph windload Model Number N-Series Lockers — Explosion Relief Panels Model Number Drum Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length N05-5004 N05-5009 N05-5015 N05-5020 N05-5030 N05-5035 N05-5040 2/1 4/1 6/1 8/1 10 / 2 12 / 2 14 / 3 96 96 118 143 168 193 236 58 70 70 70 70 70 70 98 98 98 98 98 98 98 61 64 86 111 136 161 204 49 61 61 61 61 61 61 82 82 82 82 82 82 82 54 54 54 54 54 54 54 54 Hurricane Rated Designs. 2-IBC tote Locker’s double, full face opening doors allow easy access to both totes. Exterior Dimensions (ft) Bay Dimensions (in) Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Sump Volume (gal) 80 80 80 80 80 80 80 1,700 1,900 2,400 2,900 3,400 3,800 5,100 1,200 2,400 3,600 4,800 6,000 7,200 8,400 96 121 162 209 256 304 388 Door Opening (in) IBC Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length K17-3583 K17-3585 1/1 2/1 99 153 70 70 100 88 69 123 62 62 61 61 87 121 61 61 61 61 Exterior Dimensions (ft) Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Sump Volume (gal) 54 54 80 80 2,300 3,100 5,000 10,000 559 501 61 64 54 54 80 80 2,300 2,900 5,000 10,000 506 501 61 64 54 54 80 80 2,300 2,900 5,000 10,000 560 501 Bay Dimensions (in) Door Opening (in) IBC Lockers / Non-Combustible — 150 mph windload P19-2050 P19-2055 1/1 2/1 99 153 70 70 100 88 IBC Lockers / Non-Combustible — 150 mph / DLC panels windload P19-2250 P19-2255 1/1 2/1 99 153 70 70 100 88 67 121 55
  • 29. IBC Storage Lockers Specialty Storage Lockers 2-Hour Fire Rated 2-Hour Fire Rated Added Safety for Totes Storing Flammables Secured Storage for Drums Storing Flammables Note: wo 13” vent hoods ship unattached T but are included in length dimension. odels come standard with: M ptions include: O DENIOS’ Specialty 2-Hour Fire Rated Lockers come with Automatic Closing Roll-Up Doors, providing the highest level of convenience and safety. DENIOS-Leading Supplier of FM Approved Chemical Containment Products. Sumps are sized to provide compliant spill volumes for 350-gallon totes. Roll-up door models FM Approved. Doors are UL Labeled and Rated for 1-1/2 hours in accordance with FM Standards and NFPA regulations. N-Series Lockers come in Constructed with UL- approved 2-hour rated firewall design 90 MPH and 150 MPH 4 Drum Locker with optional mechanical ventilation and dry chemical fire suppression (options sold separately). These 2-hour fire rated Tote Lockers designs provide for secured, convenient outdoor placement of 1-2 Totes near your facility. - alvanized grating above a spill G compliant sump - assive ventilation P - xterior grounding lug E - nchoring point A - FPA 704 placard N - hoose between blue, tan, C or white painted finish 2-8 Drum Locker shown with optional white color and dry chemical fire suppression (sold separately). Lockers have the same extended height allowing ample room for pumping and other activities Hurricane Rated Designs. Complies with fire rating requirements for storage of flammables within 10 feet of your facility Lockers for 1-2 IBC, 2-hour fire rated design is constructed with UL Approved firewalls. Roll-up doors includes fuse link and will automatically close in case of fire. Built to carry the higher loads from IBC’s Sump volumes meet EPA and UFC requirements Lockable hinged and roll-up doors provide full face opening, easing material handling in and out of the Locker - amp and shelves R - ire bottle (FE-241) F - ry chemical fire suppression system D - .8 or 3.6kw electric heater with 1 R-10 insulation - 4,000 BTU air conditioner with 1 R-10 insulation - nterior light (300W) with fan (350 CFM) I - xterior light (500W) with photo eye E - iberglass grating and poly sump liner F for storing acids / caustics Roll-up door has fuse link automatic closing in case of fire Note: wo 13” vent hoods ship unattached T but are included in length dimension. DENIOS-Leading Supplier of FM Approved Chemical Containment Products. N-Series Lockers come in 90 MPH and 150 MPH Hurricane Rated Designs. Single or double IBC Locker with hinged door designs to ease material handling / entry into the Locker. Specialty Lockers / 2-Hour Fire Rated — 90 mph Hurricane Rated Designs Model Number IBC Lockers / 2-Hour Fire Rated — 90 mph windload Model Number IBC Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length P19-1250 P19-1255 P19-1300 P19-1305 1/1 1/1 2/1 2/1 99 99 153 153 74 81 70 81 100 117 88 102 58 58 112 112 56 56 56 56 60 60 60 60 56 112 55 56 71 71 Exterior Dimensions (ft) Bay Dimensions (in) Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Sump Volume (gal) 55 53 108 108 60 60 60 60 3,900 3,900 5,200 5,200 5,000 5,000 10,000 10,000 438 438 423 423 53 108 60 60 3,900 5,200 5,000 10,000 438 423 Door Opening (in) IBC Lockers / 2-Hour Fire Rated — 150 mph windload P19-2150 P19-2155 56 1/1 2/1 99 153 81 81 117 102 Drum Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length P19-1005 P19-1055 P19-1105 P19-1155 2/1 4/1 6/1 8/1 96 96 118 143 58 81 81 81 105 105 105 105 56 55 77 102 44 56 57 57 81 81 81 81 81 81 81 81 Exterior Dimensions (ft) Bay Dimensions (in) Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Sump Volume (gal) 51 51 73 98 71 71 71 71 3,000 3,400 4,100 4,800 1,200 2,400 3,600 4,800 76 98 136 180 51 51 73 98 71 71 71 71 3,000 3,400 4,100 4,800 1,200 2,400 3,600 4,800 72 93 130 173 Door Opening (in) Specialty Lockers / 2-Hour Fire Rated — 150 mph Hurricane Rated Designs P19-2105 P19-2110 P19-2115 P19-2120 2/1 4/1 6/1 8/1 96 96 118 143 68 81 81 81 105 105 105 105 53 53 75 100 43 55 55 55 57
  • 30. Storage Locker Options Custom Engineered Storage Lockers Like our Cabinets and Buildings, DENIOS can custom engineer our Lockers to meet the requirements of just about any application. Customized Lockers have included heated and cooled models, custom door sets, fixed shelves, as well as designs for specialized dispensing. In addition, DENIOS also engineers it’s Lockers for process heating applications, utilizing either steam or electric heat and achieving temperatures up to 300°F. Standard options (see adjoining page) are available by Locker Series. K-Series Lockers IBC Lockers All models come standard with galvanized grating above a spill compliant sump, passive ventilation, exterior grounding lug, anchoring point and NFPA 704 placard. All models come standard with galvanized grating above a spill compliant sump, passive ventilation, exterior grounding lug, anchoring point and NFPA 704 placard. Choose between blue, tan, or white painted finish. There are no options available. PK-Series Lockers All models come standard with galvanized grating above a spill compliant sump, passive ventilation, exterior grounding lug, anchoring point and NFPA 704 placard. Choose between blue, tan, or white painted finish. Fire rated Locker with mechanical ventilation. Optional fixed shelf provides for storage of small packages of flammables. Automatic fire doors remain open for access to packages and will close in case of fire in or outside of the Locker. Options include dry chemical fire suppression system, 1.8 or 3.6kw electric heater with R-10 insulation, 14,000 BTU air conditioner with R-10 insulation, exterior light (500W) with photo eye and fiberglass grating and poly sump liner for storing acids/caustics. O ptions include ramp, interior light (300W) with fan (350 CFM), exterior light (500W) with photo eye, shelves and fire Bottle (FE-241). N-Series Lockers All models come standard with galvanized grating above a spill compliant sump, passive ventilation, exterior grounding lug, anchoring point and NFPA 704 placard. Choose between blue, tan, or white painted finish. Optional double roll-up doors allow for easier handling and processing of totes. 58 Double tote Locker with fire rated construction and mechanical ventilation. Specialty Lockers All models come standard with galvanized grating above a spill compliant sump, passive ventilation, exterior grounding lug, anchoring point and NFPA 704 placard. Choose between blue, tan, or white painted finish. Options include ramp and shelves, water sprinkler, fire bottle (FE-241), dry chemical fire suppression system, 1.8kw and 3.6kw electric heater with R-10 insulation, 14,000 BTU air conditioner with R-10 insulation, interior light (300W) with fan (350 CFM), exterior light (500W) with photo eye and fiberglass grating and poly sump liner for storing acids/caustics. Options include ramp and shelves, water sprinkler, fire bottle (FE-241), dry chemical fire suppression system, 1.8 or 3.6kw electric heater with R-10 insulation, 14,000 BTU air conditioner with R-10 insulation, interior light (300W) with fan (350 CFM), exterior light (500W) with photo eye and fiberglass grating and poly sump liner for storing acids/caustics. 59
  • 31. Enclosed HazMat Stations Keeps Drums Secure and Accessible for Storage or Dispensing Flexible Design Allows for Shelving and Dispensing Options Enclosed HazMat Stations are complete with lockable, hinged lid and doors for storing hazardous materials securely outdoors. DENIOS HazMat Stations are designed to provide a safe, secure environment for storage, dispensing, and mixing of small volumes of chemicals. Featuring a weather-proof, lockable hinged lid and doors, they provide personnel easy access to the tops of drums and other stored chemicals for dispensing and mixing operations. When dispensing, any spills or drips are contained by a built-in, compliant spill sump. HazMat Stations for 2 and 4 Drums access to tops of drums, lid lifts easily For and is supported by heavy duty gas cylinders Solidly welded steel construction for extended life O ptional shelving packages provide efficient, secured exterior storage for smaller containers. Sump welds are 100% inspected with a low-viscous test to insure leak-tightness Add drum cradles to create a mixing and dispensing station which provides compliant spill containment. 66-Gallon sump volumes meet EPA and UFC requirements Passive ventilation is standard Coated with a durable, corrosion and weather resistant finish Double tote Locker with fire rated construction and heating. Removable galvanized steel grating for easy cleanup 4 drum HazMat Station with half width shelf. Four-way forkliftable HazMat Station for 2 Drums. Contact Us: HazMat Station 60 Model Number Capacity per Cabinet (55 gal drums) Length Depth K17-3502 2 54 K17-3503 For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l info2@denios-us.com Height Shipping Weight (lbs) Load Capacity per Bay (lbs) Sump Volume (gal) 34 55 425 1,200 66 4 56 56 55 585 2,400 66 Exterior Dimensions (ft) HazMat Station with steel sump and grating for 4 drums. 4 drum HazMat Station with half width shelf and single drum cradle. 61
  • 32. Automatic Doorway Spill Barriers In cases of catastrophic spills or sprinkler releases, containing the spill to a single room or area can limit the costs associated with clean-up or facility damage. Fully automatic operation ensures barrier will close even in cases of power loss DENIOS Automatic Doorway Spill Barriers provide the protection to contain those large spills by closing off any doorway or opening in the affected room at the first sign of flowing liquids. Features of the Automatic Doorway Spill Barrier Include: Solid welded stainless steel construction Federal Regulations along with Local Jurisdictions require that sprinkler water in combination with regulated or hazardous materials be prevented from being released into the environment via sewers, streams, or ground contamination. When a release occurs, fines and clean-up costs can be staggering. Self-contained one piece system design NFPA-30 9.13.3 While laying flat, Barrier provides up to 6.5 tons axle weight capacity Curbs, scuppers, special drains, or other suitable means shall be provided to prevent the flow of liquids under emergency conditions into adjacent building areas. Fully automatic operation, no external power source or factory compressed air required Easy installation in existing doorways; stores horizontally in the floor, permitting unobstructed vehicular and personnel traffic until a spill occurs Barriers prevent spills from reaching storm drains or contaminating ground water Designed to fit in doorways between 3 and 16 feet, with barrier heights of 12 to 24 inches Automatic Doorway Spill Barriers are often utilized as containment equipment for Flammables Storage Rooms Operation – Flow of liquid triggers the Barrier to automatically shut IFC-2704.2.2.3 (2009) Secondary containment for indoor storage areas shall be designed to contain a spill from the largest vessel plus the design flow volume of fire-protection water calculated to discharge from the fire-extinguishing system over the minimum required system design area or area of the room… for a period of 20 minutes. OSHA 1910.106 (e) (3) (iv) (a) W hen not deployed, Barrier door stores flat in floor, eliminating the need for ramps or berms. Automatically closes with introduction of liquid in the built-in collection sump, creating a liquid tight seal and containing the spill in the room where it originated Emergency drainage systems shall be provided to direct flammable or combustible liquid leakage and fire protection water to a safe location. This may require curbs, scuppers, or special drainage systems to control the spread of fire. Liquid Retention Height — 12-inch Model Number OSHA 1910.106 (d) (4) (i) Openings to other rooms or buildings shall be provided with non-combustible liquid-tight raised sills or ramps at least 4” in height. 62 Liquid Retention Height — 18-inch Combine with curbing to effectively cut off and contain liquid storage areas. Nominal Width of Door (ft) Opening Span (In) Sealed Width (In) R11-0312 R11-0412 R11-0612 R11-0812 R11-1012 R11-1212 R11-1412 R11-1612 3 4 6 8 10 12 14 16 36 48 72 96 120 144 168 192 40 52 76 100 124 148 172 196 Liquid Retention Height — 24-inch Model Number Nominal Width of Door (ft) Opening Span (In) Sealed Width (In) Model Number Nominal Width of Door (ft) Opening Span (In) Sealed Width (In) R11-0318 R11-0418 R11-0618 R11-0818 R11-1018 R11-1218 R11-1418 R11-1618 3 4 6 8 10 12 14 16 36 48 72 96 120 144 168 192 40 52 76 100 124 148 172 196 R11-0324 R11-0424 R11-0624 R11-0824 R11-1024 R11-1224 R11-1424 R11-1624 3 4 6 8 10 12 14 16 36 48 72 96 120 144 168 192 40 52 76 100 124 148 172 196 63
  • 33. FM Approved Flood Barrier HazBerm DENIOS announces our new FM Approved Automatic Doorway Flood Barrier System (FM Approvals Class 2510). This barrier keeps floodwaters out of your facilities by providing a flood “wall” at your doorways. DENIOS’ Exclusive HazBerm creates large, modular containment areas within facilities – a more efficient alternative to conventional berms and curbs Provides all the durable construction and operational characteristics of our doorway spill barrier but is designed specifically for floodwaters. The Doorway Flood Barrier installs easily in existing doorways and stores horizontally in the floor, permitting normal vehicular and personnel traffic, until a flood occurs. With the first flow of water the Barrier automatically closes. No additional ramps or berms are needed. Patent-pending modular design allows for custom sizing for each application In addition, the DENIOS Automatic Doorway Flood Barrier provides: Polymer concrete segments are highly chemical and fire resistant Door heights of 12, 18, and 24 inches. Widths from 3 to 12 feet. Flexible design allows installation either inside or outside exterior doors. in combination with Doorway Spill Use Barriers to allow easy transport in and out of the berm area Doorway Flood Barrier in closed position. Systems are easily supplied and installed Easily relocated or altered as needs change – no need to jack-hammer and replace the existing system Segments seal together to form a virtually leak-proof barrier The HazBerm can be placed around processing equipment to contain potential leaks and spills HazBerm is both chemical and fire resistant DENIOS-Leading Supplier of FM Approved Chemical Containment Products. Combine with manual or automatic Doorway Spill Barriers to allow easy access to stored chemicals Available in tan or black Does not require floor footers, forms, or on-site concrete pouring HazBerm Segments — Tan In open position, Flood Barrier lays flat in floor, allowing normal traffic. Liquid Retention Height — 12-inch Liquid Retention Height — 18-inch Model Number Liquid Retention Height — 24-inch Model Number Nominal Width of Door (ft) Opening Span (In) Sealed Width (In) Model Number Nominal Width of Door (ft) Opening Span (In) Sealed Width (In) Model Number Nominal Width of Door (ft) Opening Span (In) Sealed Width (In) R11-0312 R11-0412 R11-0612 R11-0812 R11-1012 R11-1212 3 4 6 8 10 12 36 48 72 96 120 144 40 52 76 100 124 148 R11-0318 R11-0418 R11-0618 R11-0818 R11-1018 R11-1218 3 4 6 8 10 12 36 48 72 96 120 144 40 52 76 100 124 148 R11-0324 R11-0424 R11-0624 R11-0824 R11-1024 R11-1224 3 4 6 8 10 12 36 48 72 96 120 144 40 52 76 100 124 148 64 Description R05-0230 R05-0210 R05-0290 R05-0292 3’ Straight 1’ Straight 1’ Corner 1’ Reverse Corner Length Depth Height Length Depth Height Shipping Weight (lbs) 36 12 12 12 4 4 4 4 18 18 18 18 8 8 4 4 18 18 90 29 44 44 36 12 12 12 4 4 4 4 18 18 18 18 8 8 4 4 18 18 90 29 44 44 Exterior Dimensions (in) Interior Dimensions (in) HazBerm Segments — Black R05-0231 R05-0211 R05-0291 R05-0293 3’ Straight 1’ Straight 1’ Corner 1’ Reverse Corner The HazBerm is available in 1 and 3 foot segments as well as the 1 foot corner and reverse corner segments. (Reverse corner not shown. Hardware included, but not shown.) 65
  • 34. The Basics for the Handling and Storage of Flammable Chemicals – Definitions National / International Authorities International Building Code (IBC) Combustible Liquid The temperature at which the vapor pressure of a liquid equals the surrounding atmospheric pressure. International Fire Code (IFC) Boiling Point Any liquid that has a flash point at or above 100° F (37.8° C). Code of Federal Regulations (CFR) Environmental Protection Act (EPA) National Fire Protection Assn. (NFPA) Uniform Fire Code (UFC) Uniform Building Code (UBC) Grant Hart Business Development Manager DENIOS, Inc. The following pages are intended as a guide to the vast array of regulations concerning the storage and handling of flammable and combustible chemicals. As regulations and their interpretations change over time, your local Authority Having Jurisdiction (AHJ) should always be consulted when considering storing hazardous materials inside or outside your facility. These next few paragraphs will provide brief insight to help you understand some of the fundamental parts of the Code of Federal Regulations, Title 29, Parts 1900 to 1910.999, and the Occupational Health and Safety Act of 1970 regarding the external storage of flammable liquids. In addition, data has been taken from the National Fire Protection Association’s NFPA 30 “Flammable and Combustible Liquids Code”, the 2010 edition of the “International Building Code” and the 2009 edition of the “International Fire Code.” Best regards Grant Hart It is critical to understand the uniform system of defining and classifying flammable and combustible liquids and why it is important to take the necessary precautions to provide the correct methods of storage. Authority Having Jurisdiction (AHJ) An organization, office or individual responsible for enforcing code requirements or standards. Auto-Ignition Temperature The minimum temperature at or above which a material will spontaneously ignite (catch fire) without an external spark or flame. See following Table 1: Auto-Ignition Temperatures for Some Common Chemicals or Fuels Chemical or Fuel Acetone Benzene Diethyl Ether Ethylene Ethyl Alcohol Fuel Oil No. 2 Gasoline Kerosene Isopropyl Alcohol Methyl Alcohol Propane Toluene Xylene Temperature °C °F 465 560 160 490 365 256 280 210 399 385 480 480 463 869 1,040 320 914 689 494 536 410 750 725 896 896 867 Flash Point The minimum temperature of a liquid at which sufficient vapor is given off to form an ignitable mixture with air near the surface of the liquid. Flammable Liquid Any liquid that has a flash point below 100° F (37.8° C). Flammable liquids are classified as Class I liquids with further sub-classification per the following and as shown in Figure 1: Class IA – Any liquid that has a flash point below 73° F (22.8° C) and a boiling point below 100° F (37.8° C). Examples of this class are Ethyl Ether and Pentane. Class IB – Any liquid that has a flash point below 73° F (22.8° C) and a boiling point at or above 100° F (37.8° C). Examples of this class are Gasoline and MEK. Class IC – Any liquid that has a flash point at or above 73° F (22.8° C) but below 100° F (37.8° C). Examples of this class are Xylene and Turpentine. lass II – Any liquid that has a flash point at C or above 100° F (37.8° C) and below 140° F (60° C). Examples of this class are Kerosene and Oil-Based paints. Class III – Any liquid that has a flash point above 140° F (60° C) 1) lass IIIA Liquid – Any liquid that has a C flash point at or above 140° F (60° C), but below 200° F (93° C). An example of this is Mineral Spirits. 2) lass IIIB Liquid – Any liquid that has C a flash point at or above 200° F (93° C). Examples of this class are Hydraulic Brake / Transmission fluids and lube oils. The maximum quantity of flammable or combustible liquids allowed to be stored in a given occupancy. The MAQ varies per the occupancy class and the fire protection systems available. But in general it begins at 120 gallons of liquid. Control Area Defined in NFPA 30, Section 9.7 and generally defined as follows: 1. building or portion of a building within which A flammable and combustible liquids are allowed to be stored, dispensed and used or handled in quantities of liquids that do not exceed those listed in NFPA 30 Table 9.6.1 or Table 9.6.2 for all liquid Classes I, II and III. “H” Occupancy Occupancy where the quantity of flammable liquid or other hazardous material stored exceeds the MAQ. Storing quantities above MAQ generally makes the occupancy a “hazardous occupancy” (H1-H5). Most DENIOS Lockers, Cabinets and “walk in” style Buildings fall into these two categories: -2 – Class I, II or IIIA flammable or H combustible liquids which are used or stored in NORMALLY OPEN containers or systems, or in closed containers pressured at more than 15 psig. -3 – Class I, II or IIIA flammable or H combustible liquids which are used or stored in NORMALLY CLOSED containers or systems, or in closed containers pressured at 15 psig or less. 2. n area separated from each other by fire A barriers per NFPA Table 9.7.2. 200 140 100 Flash Point Temp, °F II IIIA IIIB Combustible Classification Classification of Flammable Liquids Indicates liquid boiling point Flammable Range (Explosive Range) Indicates liquid flash point The range of a concentration of a gas or vapor that will burn (or explode) if an ignition source is introduced. 100 73 Temp, °F IA IB IC Flammable Liquide Classification 66 Combustible liquids are classified per the following and as shown in Figure 2: MAQ (Maximum Allowable Quantity) 4 drum Locker with fire rated construction for storage of flammable liquid chemicals. 67
  • 35. Storage of Flammable Liquids Chemical Spill Containment Requirements Storage of Flammable Liquids in Quantities exceeding 120 gal (460L) Storage of flammable liquids in Chemical Storage Structures inside an existing building Deflagration control Storage of Flammable Liquids in Quantities not exceeding 120 gal (460L) The storing of Class I, II and IIIA liquids in individual containers shall meet all the applicable requirements of NFPA 30. When flammable or combustible liquids are stored in a chemical storage structure that is less than 500 ft2 and is located inside of an existing structure, the chemical storage structure is classified as a Liquid Storage Room and must meet the requirements prescribed. Where flammable liquids are dispensed, deflagration panels or control should be provided. The exterior wall containing the panels should be a minimum of 30 feet from another building and the area adjacent to the panels should be kept clear of pedestrian traffic for 30 feet as well. For this application, a flammable liquids storage cabinet as approved or listed by a recognized third party agency or constructed per NFPA 30 will suffice. The Local Authority Having Jurisdiction should be consulted regarding the number of cabinets allowed per control area (see definition above). Explosion prevention systems can be provided which include LEL detectors, multiple fans and associated controls to maintain the vapor level at or below 25% of the Lower Explosive Limit (LEL). DENIOS’ HAZMATTER: Typically, flammable liquids storage cabinets are designed to have a sump or spill containment volume of 5 gallons which is based upon storage of typical containers having a volume of 5 gallons or less. However, some of these cabinets are designed to store (2) 55 gallon drums (still within the 120 gallon limit) and DENIOS believes that these cabinets should be compliant under EPA and UFC regulations. Therefore, DENIOS offers a Flammable Cabinet Sump that can be added to the Flammable Cabinets bringing the complete system into EPA and UFC compliance. Make sure to consult your local Authority Having Jurisdiction (AHJ). Material must be separated from the rest of the occupancy either by distance or by fire rated walls. DENIOS Lockers, Cabinets and “walk in” style Buildings are designed for this purpose. Table 2 adjacent is designed to provide general guidance as to separation distances relative to required fire ratings. Minimum Separation Distance from Storage Structure to Property Line or other Important Building Fire Rating (hrs) Distance (ft) 4 2 0 0 10 30 Ventilation Chemical storage structures used for storing combustible and flammable liquids should be ventilated. The ventilation method can be either passive (natural) or mechanical (forced). In most cases air should be drawn from a location within 12-18” of the floor as the majority of flammable liquids give off vapors that are heavier than air. Contact Us: For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l info2@denios-us.com 2 Hour Fire Rated Locker for two IBC Totes with mechanical ventilation system to remove flammable vapors. 68 Secondary Containment Containment is described in the Fire Code, Flammable Liquids Code and the Code of Federal Regulations (CFR). In general the capacity of the containment must be 10% of the aggregate liquid volume stored or the volume of the largest container stored whichever is larger. Where the storage is indoors and a sprinkler system is in place, local jurisdictions and third party certifiers may have more stringent requirements. Flammable Cabinet sump provides added capacity bringing the system into spill compliance. All DENIOS Cabinets, Buildings, and Lockers provide compliant secondary containment sumps below a grated surface. 69
  • 36. Storage of Organic Peroxides Controlling Storage Temperatures Key Organic Peroxides present special challenges for storage and handling as they are temperature sensitive and can combust spontaneously if they reach certain temperatures unique to each material. Self Accelerating Decomposition Temperature Organic Peroxides decompose at various temperatures giving off heat that can cause or contribute to a fire. This temperature is called Self Accelerating Decomposition Temperature, or SADT, and can be anywhere between -10 to 200C depending upon the material. Control Temperature Another important temperature is the CT or Control Temperature. This is the temperature at which the material can be stored or transported over a long periods of time. This temperature varies between 0 and 20 C less than the SADT depending upon the SADT. CT=SADT – 20° C if SADT20°C CT=SADT – 15°C if SADT 20° C but 35°C CT=SADT – 10° C if SADT35° C but 50°C IF SADT 50°C then there is no CT. The CT can also be thought of as the alarm temperature when storing the given material. Redundant cooling system ensures temperature stability should primary system fail. 70 Proper Storage of Organic Peroxides Since it is well below the SADT it may be exceeded for short time periods due to maintenance or until alternative cooling methods are available. Still another temperature may come in to play. That is the recommended storage temperature from the manufacturer of the material. This may be even lower than the CT to prevent the material from degrading, decreasing its usefulness. Thus the key to managing organic peroxides is temperature. If they are maintained at the appropriate temperature in accordance with the manufacturer’s instructions, they can be handled and stored safely. Organic Peroxides by Definition Storage areas for organic peroxides must also be separated from other chemicals including flammables, oxidizers, acids and alkalis by a minimum of 25 feet or a liquid tight one hour fire barrier. Class I (see definitions below) peroxides provide extra challenges as they are considered explosive. Deflagration panels and special building reinforcement are called for when storing these materials. Areas where organic peroxides are stored should be electrically classified as CL I Div 1 or Div 2 as designated by NFPA 400. In addition controls on the refrigeration system should include over temperature alarms (usually set at the Control Temperature) and a smoke or heat detector to notify the appropriate response of a problem in the storage area. Redundant temperature control equipment or approved alternate means should be available in the event of equipment failure. Standby or emergency power should also be considered per NFPA 400. Organic Peroxides are divided into five classes by NFPA 400 Chapter 14 for storage, fire fighting and safety reasons. Class III formulations burn rapidly and present a moderate reactivity hazard. They are similar to combustible liquids such as #2 fuel oil. Class I is the most dangerous class of Organic Peroxides and describes those materials that present a hazard of deflagration through rapid explosive decomposition. Such materials are safe only under strictly controlled temperatures. Dibenzoyl peroxide 98% is one such material. Class IV describes those formulations that burn in a manner similar to ordinary combustibles. These fires are easily controlled. Class V materials burn with less intensity than ordinary combustibles and do not present a severe fire hazard. Class II formulations present a fire hazard similar to Class I flammable liquids such as acetone or toluene. Class 1 Organic Peroxide Storage Enclosures can require deflagration panels due to the explosive hazards of the material stored. 71
  • 37. Third Party Approvals What they are and why they are important. Setting the record straight. Setting a standard for quality, performance, and construction Third party approvals for Hazardous Material Buildings have been around since 1991 in the form of FM class 6049. FM began approving hazardous material storage buildings with the first edition of CLASS 6049 in that year. This FM “standard” has remained the defacto standard in the US, unchallenged since that time. Manufacturers that receive FM approval have submitted their designs to a third party and then to FM for review in accordance with the standard. This includes reviewing the structural integrity including floor and snow loads in accordance with the standards and the ability of the building to withstand a specific wind which is especially important in coastal areas of the US. The standard further evaluates the integrity of fire rated walls and ceiling and certifies the stated containment sump capacity. Contrary to popular opinion, UL (Underwriters Laboratories) does not have a standard for these buildings, so no manufacturer can use the “UL listed” moniker with reference to their buildings. A FM approved building should be labeled as such by the manufacturer. The text of the approval document prescribes what must be on the label. This includes place of manufacture, model no., design floor, wind and snow loads, and if applicable, the fire rating of the walls. It also includes whether the building is constructed with damage limiting construction (DLC) also known as deflagration panels, and the electrical classification and temperature classification of any and all electrical equipment installed on the building. DENIOS’ FM Approved fire rated Cabinet. DENIOS is presently the only manufacturer with FM Approved Cabinets. 72 It is important to note that, even though a manufacturer has multiple items in their approval listing, there may be variations of those products that cannot be labeled as “approved”. This is because the approval listing contains specific construction parameters and characteristics that may or may not be available in a particular model series or combination of accessories. A third party approval is important because it sets a standard of consistent quality, performance, and construction that is guaranteed by the fact that the building carries the approval. Further, in this case of FM, periodic follow up inspections of the approved company’s manufacturing site(s) are conducted by FM engineers to assure that the approved products are being manufactured in the same manner as was initially examined. Repeated violations can result in the withdrawal of the approval. While the third party approval certifies a level of engineering, quality and construction, it does not certify a fitness for a specific use nor placement in a specific location. Suitability for use and location are best determined in consultation with your local authority having jurisdiction. While significant, the approval should be considered a minimum acceptable standard as many manufacturers go above and beyond that required for the approval. At the same time, all FM approved manufacturers may not be equal. While the FM approved moniker denotes a specific level of manufacture for basic standard buildings, the manufacturer’s expertise in building the actual requirements dictated by the application should also be taken into account when evaluating a particular project. For instance, experience in building heated enclosures with specific heating mediums i.e. steam, electric or oil should be evaluated if these characteristics are requirements of the project as they are not a part of the FM approval process. Further, experience in cooled or refrigerated units should be evaluated if these features are needed in the scope of the contemplated project. These characteristics are also not contemplated by the FM Approval Process. A 6-drum, FM Approved, non-combustible Locker Design Other drum / IBC storage enclosures approved by FM include modular Buildings. 73
  • 38. An extra bonus in selection and information 24 hours a day... www.denios-us.com Just click away! DENIOS web site is open all hours. Comprehensive, informative and now with even The greater choices. Take a look at our site and bookmark the page as a favorite in your browser. Check back often! We’re constantly adding new products and information to the site. Stay updated with the latest innovations in chemical storage and spill containment at denios-us.com. Easy-to-use search engines: You’ll always find what you’re looking for! Place an order whenever you want: Open twenty-four hours a day! Easy to navigate site highlights the most innovative chemical storage products! Success stories, technical brochures and much more! Presentation of innovative developments, including product videos! Info pages with extracts from current regulations! Besides our project business we also offer a wide range of standard products... To view our full product catalogue please visit www.denios-us.com 74 75
  • 39. We want to make sure our catalog reaches the right people at the right address. If your address is incorrect, please call us at 800-216-7776 and we’ll fix it immediately. And if you don’t wish to receive the catalog, please don’t throw it away- pass it along to a co-worker who deals with industrial chemicals, safety, or maintenance. Thank you! Engineered Products The DENIOS Vision DENIOS, Inc. DENIOS is the worldwide leader in hazardous materials 1152 Industrial Blvd. storage, industrial environmental protection, and workplace Louisville, KY 40219 health and safety. Our highly motivated and skilled team is Phone: 502-933-7272 or 866-384-4889 constantly searching for new ideas and creative innovations, Fax: 502-933-1560 making a positive impact in shaping the future. We provide E-Mail: info2@denios-us.com customer benefits through exceptional product quality, www.denios-us.com prompt delivery and outstanding customer support and communication. DENIOS pledges to be a confidence inspiring project partner and reliable problem solver for all environmental protection and workplace safety applications. 76 The environment‘s partner

×