Steel Skid
35 lb 12” I-Beams with
cross members and
outriggers
2 x 12 Floor Joists-16” O.C. Flooring is
nailed & screwed and are doubled every
48”. A “ladder” header is installed @ fron...
R-38 Floor Insulation with 1-layer of
foil bubble insulation
Entire Floor is covered with 30 GA
Galvanized Steel
Installation of 16”x16”
vinyl floor tiles. Floor is
sanded and cleaned and
floor tiles are glued and
rolled and installed ...
Pre-engineered roof trusses installed
16” O.C . Trusses are glued and
foamed to ceiling panels
Insulated duct for
Heating/Air
Conditioning of unit

Installed in roof cavity
and supported with
strapping.
Exterior walls: 2” x 6” @ 16” O.C.
Interior walls: 2” x 4” @ 16” O.C.
All walls are strapped to floor and roof
area and sc...
Installation of roof area to unit. Roof will be screwed and
strapped to unit
Exterior walls are insulated
with R-21Fiberglass insulation
Exterior Sheathing for unit is 7/16”
OSB with 1-layer of foil bubble
insulation.
Roof area is insulated with R-49
fiberglass insulation and is covered
with 7/16” structural grade OSB
Unit is built with Low-E
insulated windows with clear
glass. Exterior walls are
covered with 26 GA “R-panel”
colored steel
Roof area is covered with
roof paper and exterior
metal trim pieces are
installed prior to install of
steel roof

Installa...
Electrical: Unit is powered to a 200
amp service panel. Each unit will
include a H.V.A.C: 2.5 /4.0 ton
exterior mount unit...
Exterior Doors: 30”x68” steel door
with steel framing and flange.
Exterior Incandescent light with
cover is installed next...
Baths: 1 pc. Fiberglass shower(s) are
included. Vanity area—cultured marble top
with single lever faucet /bar light with
m...
Digital
Thermostat

Ceiling Vent
for Heat/AC

Recessed wall mounted
heater
Standard 2-Bulb ceiling light
fixture

Strip light with receptacle.
Mounted above area of bunk
Drain line(s), water-inlet valve
accessible from exterior. Unit
will have (2) exterior weather
resistant receptacles

Weat...
Kitchen: Wood framed cabinet doors with base
and overhead cabinets. Appliance: Upgraded
range, microwave over range and re...
Skid unit—Office area.
Desk areas included with
countertops, drawers, and
overhead cabinets.

Office area also includes al...
Safety: All Skid units will include
“EXIT” signs @ exterior doors and a fire
extinguisher mounted under kitchen
sink area
Skid unit -presentation of bunk housing, oil field, gas field, man camps
Skid unit -presentation of bunk housing, oil field, gas field, man camps
Skid unit -presentation of bunk housing, oil field, gas field, man camps
Skid unit -presentation of bunk housing, oil field, gas field, man camps
Upcoming SlideShare
Loading in …5
×

Skid unit -presentation of bunk housing, oil field, gas field, man camps

516 views
386 views

Published on

Skid units for man camps, oil field man camps, gas field man camps, modular construction solutions for oil and gas field man camps, temporary housing for oil and gas fields,

Published in: Real Estate, Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
516
On SlideShare
0
From Embeds
0
Number of Embeds
11
Actions
Shares
0
Downloads
3
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Skid unit -presentation of bunk housing, oil field, gas field, man camps

  1. 1. Steel Skid 35 lb 12” I-Beams with cross members and outriggers
  2. 2. 2 x 12 Floor Joists-16” O.C. Flooring is nailed & screwed and are doubled every 48”. A “ladder” header is installed @ front and rear of floor for installation support to steel skid. Floor Decking is 1 1/8” Thick!
  3. 3. R-38 Floor Insulation with 1-layer of foil bubble insulation
  4. 4. Entire Floor is covered with 30 GA Galvanized Steel
  5. 5. Installation of 16”x16” vinyl floor tiles. Floor is sanded and cleaned and floor tiles are glued and rolled and installed over entire floor.
  6. 6. Pre-engineered roof trusses installed 16” O.C . Trusses are glued and foamed to ceiling panels
  7. 7. Insulated duct for Heating/Air Conditioning of unit Installed in roof cavity and supported with strapping.
  8. 8. Exterior walls: 2” x 6” @ 16” O.C. Interior walls: 2” x 4” @ 16” O.C. All walls are strapped to floor and roof area and screwed per code.
  9. 9. Installation of roof area to unit. Roof will be screwed and strapped to unit
  10. 10. Exterior walls are insulated with R-21Fiberglass insulation
  11. 11. Exterior Sheathing for unit is 7/16” OSB with 1-layer of foil bubble insulation.
  12. 12. Roof area is insulated with R-49 fiberglass insulation and is covered with 7/16” structural grade OSB
  13. 13. Unit is built with Low-E insulated windows with clear glass. Exterior walls are covered with 26 GA “R-panel” colored steel
  14. 14. Roof area is covered with roof paper and exterior metal trim pieces are installed prior to install of steel roof Installation of 30 GA galvanized steel over roof with a gutter flange installed to length of unit.
  15. 15. Electrical: Unit is powered to a 200 amp service panel. Each unit will include a H.V.A.C: 2.5 /4.0 ton exterior mount unit.
  16. 16. Exterior Doors: 30”x68” steel door with steel framing and flange. Exterior Incandescent light with cover is installed next to door.
  17. 17. Baths: 1 pc. Fiberglass shower(s) are included. Vanity area—cultured marble top with single lever faucet /bar light with medicine cabinet and towel bar and tissue holders
  18. 18. Digital Thermostat Ceiling Vent for Heat/AC Recessed wall mounted heater
  19. 19. Standard 2-Bulb ceiling light fixture Strip light with receptacle. Mounted above area of bunk
  20. 20. Drain line(s), water-inlet valve accessible from exterior. Unit will have (2) exterior weather resistant receptacles Weather-Proof Exterior box for communications to be brought into the bunk unit.
  21. 21. Kitchen: Wood framed cabinet doors with base and overhead cabinets. Appliance: Upgraded range, microwave over range and refrigerator. Cabinets will also include shipping clips for transportation closure.
  22. 22. Skid unit—Office area. Desk areas included with countertops, drawers, and overhead cabinets. Office area also includes all electrical receptacles and phone jacks at desk area(s)
  23. 23. Safety: All Skid units will include “EXIT” signs @ exterior doors and a fire extinguisher mounted under kitchen sink area

×