[PSS 21H-2Y12B4] Intrinsically Safe Termination Assembly ...
Upcoming SlideShare
Loading in...5
×
 

[PSS 21H-2Y12B4] Intrinsically Safe Termination Assembly ...

on

  • 1,009 views

 

Statistics

Views

Total Views
1,009
Views on SlideShare
1,009
Embed Views
0

Actions

Likes
0
Downloads
9
Comments
0

0 Embeds 0

No embeds

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

[PSS 21H-2Y12B4] Intrinsically Safe Termination Assembly ... [PSS 21H-2Y12B4] Intrinsically Safe Termination Assembly ... Document Transcript

  • PRODUCT SPECIFICATIONS I/A Series® Hardware PSS 21H-2Y12 B4 Intrinsically Safe Termination Assembly - Base Plate (ISTA-*BP*) The ISTA-*BP* combines Invensys Foxboro and Pepperl+Fuchs products. It is a combination of a baseplate with integrated terminals fitted with one or two Fieldbus modules (FBMs) and eight galvanic isolators, resulting in less cabinet space required. This solution consists of a printed circuit board and therefore does not require any additional wiring on the board, offering a reliable interface between the control processor and field I/O sensors and actuators. FEATURES Intrinsically safe Key features of the ISTA-*BP* are: Online Baseplate Replacement Provides a motherboard for up to two Fieldbus Fault detection - Various types of HiD2000 Modules (FBMs) Modules have a separate fault detection output Supports simplex, dual or redundant FBM to identify a fault condition such as lead breakage applications or short circuit. Offers galvanic isolation to FBM applications; Used in any sites which can include 200 Series supports applications for Analog Input, Analog FBMs, such as CP60, FCP270 or ZCP270 Output, Digital Input and Digital Output including installations. HART FBMs
  • PSS 21H-2Y12 B4 Page 2 Electrical connections: COMPACT DESIGN • All connections on board Baseplate • Two primary and two Secondary power The ISTA-*BP* has a compact design with integrated supply connections slots fitted for one or two Fieldbus modules (FBMs) and for eight galvanic isolators and terminations for • Fault Output connection connecting the field devices to the baseplate. This • Supports daisy-chain connection for power- solution consists of a printed circuit board and and HDLC Fieldbus-connection therefore does not require any additional wiring on HART Multiplexer connection to Pepperl+Fuchs the board, offering a reliable interface between the type MUX2700 G using a 37-pin Sub-D- control processor and field I/O sensors and connector actuators. The resulting compact packaging offers a noticeable space saving in the interface cabinet. Baseplate addressing - DIP switch array with five switches on the baseplate. The ISTA-*BP* Enclosure provides additional DIP switches to indicate the Enclosures specially designed for mounting the letterbug of a particular FBM slot. FBMs provide various levels of environmental OVERVIEW protection, up to harsh environments per ISA The ISTA-*BP* (Intrinsically Safe Termination Standard S71.04. These enclosures must be Assembly - Base Plate) is designed for applications installed according to intrinsically safe principles in requiring protection of process control signals from or order to be rated as intrinsically safe. to approved field devices in hazardous (classified) locations. The baseplate offers a specialized interface VISUAL INDICATORS for I/A Series 200 Series FBMs. Baseplates are Light-emitting diodes (LEDs) incorporated onto the available for Simplex FBMs with single baseplate top of each HiD module provide visual indication of slots, and for further space reductions, dual-slotted the module's operational status. baseplates for either redundant FBMs or two Simplex FBMs are available. EASY REMOVAL / REPLACEMENT Eight galvanic isolators approved as intrinsically safe The FBM and the HiD module can be associated apparatus are mounted on the baseplate removed/replaced without removing field device and are protective barriers keeping dangerous termination cabling, power, or communications electrical energy from entering the hazardous areas. cabling. The HiD modules consist of a quick-lock These isolators are Pepperl+Fuchs' HiD2000 (High mechanism that allows replacement without any Density) Modules. tools. The ISTA-*BP*s are available for different FBM types. Please refer also to the documentation listed on page 16 and the respective FBM Product Specification Sheets.
  • PSS 21H-2Y12 B4 Page 3 ONLINE BASEPLATE REPLACEMENT Each ISTA-*BP* includes a third 9-pin Sub-D plug, to assist in replacing an adjacent ISTA-*BP* without interrupting HDLC communications. A ISTA-*BP* can bypass its adjacent baseplate by connecting this third plug to another baseplate Primary further downstream from the baseplate to be 2-Wire Cable replaced. The bypassed ISTA-*BP* can then be removed safely. When the replacement procedure is complete, the standard cables can be reattached to the second plug, and the connections between the Daisy third plugs are removed. Normal HDLC Chain communications are restored. Secondary FIELDBUS COMMUNICATION Ring 2-Wire Circuit Cable A Fieldbus Communication Module (FCM10 or FCM100 type) or a Control Processor (FCP270) is directly connected to the ISTA-*BP* and interfaces the redundant 2 Mbps module Fieldbus used by the FBMs. The FBM accepts communication from either Figure 1. Power Distribution to ISTA-*BP* path (A or B) of the redundant 2 Mbps fieldbus - should one path fail or be switched at the system Daisy-chaining provides further levels of redundancy. level, the module continues communication over the Each baseplate has four cable paths for sourcing active path. power from the redundant power supplies. In this The ISTA-*BP* can be used in series with non- manner, an individual ISTA-*BP* can withstand up to intrinsically safe baseplates if required. three individual power cable failures without affecting the operation of the FBMs. If at any time an FBM POWER CONNECTIONS loses either primary or secondary power, a system Each ISTA-*BP* contains connections for primary alarm will be generated. and secondary supplies. It is recommended that As well, this configuration will greatly reduce the ISTA-*BP* modules are connected by applying a amount of power supply cabling by not requiring daisy-chained connection between each individual each ISTA-*BP* to have a dedicated cable to both baseplate and closing the loop from the other end by the primary and secondary power supplies. applying a ring circuit, as shown in Figure 1.
  • PSS 21H-2Y12 B4 Page 4 ISTA-*BP* MOUNTING The ISTA-*BP* is DIN rail mounted, as are all termination assemblies for 200 Series FBMs. The FBM and the galvanic isolators mount onto the baseplate. TERMINATION The baseplate consist of 9-pin sub-D-connectors for the redundant Fieldbus to the FCM or FCP/CP and screw terminals for the redundant independent dc power, and for the fault detection. Field devices are connected to the screw terminals on the baseplate. No additional terminal blocks are required. Standard Fieldbus terminators, such as P0916RB, are used on the baseplate at the end of the daisy- chain. Refer to PSS 21H-2W6 B4 DIN Rail Mounted Modular Baseplates for more information on these terminators. CONTENTS OF ISTA-*BP* Baseplate HiD2000 Modules Plug for power supply (4 pieces) Plug for fault messages (1 piece) FBMs are packaged separately.
  • PSS 21H-2Y12 B4 Page 5 F UN C T ION A L S PE C IF I C ATI ONS Field Device Channels Regulatory Compliance of ISTA-*BP* without INTERFACE FBMs Galvanic isolation is offered in various versions COMPLIANCE WITH EUROPEAN DIRECTIVES depending on the FBM version and the applied European Directive 94/9/EC for equipment and HiD modules: protective systems intended for use in potentially 8 channels with single channel HiD explosive atmospheres 16 channels with two-channel HiD Meets: EN50020 32 channels with four-channel HiD ELECTROMAGNETIC COMPATIBILITY (EMC) COMMUNICATION TO THE DEVICE European EMC Directive 89/336/EEC for Point-to-point Electromagnetic Compatibility. Meets: EN 61326 Annex A (Industrial Levels) ERROR CHECKING / INDICATION Conformity One green LED on HiD module to indicate Protection degree according to IEC 60529 “power on” IEC DIRECTIVES POWER SUPPLY The baseplate does not fall under this directive. ISTA-*BP*: 24 V dc (20.4 V.... 30 V) The FBMs and HiD modules fulfil the following Fault Bus: 30 V with 10 mA directives See PSS for FBMs and Table 2 on page 14. IEC 61000-4-2 ESD Immunity GALVANIC ISOLATION Contact 4 kV, air 8 kV By using the ISTA-*BP* each channel is IEC 61000-4-3 Radiated Field Immunity galvanically isolated from each other. 10 V/m at 80 to 1000 MHz The FBMs offer galvanically isolated (both optical IEC 61000-4-4 Electrical Fast and transformer isolation) as a group from ground Transient/Burst Immunity and module logic. 2 kV on I/O, dc power and communication CAUTION lines Please observe the specifications for the IEC 61000-4-5 Surge Immunity respective FBM, HiD module and the 2kV on ac and dc power lines; 1kV on I/O and communications lines ISTA-*BP* Instruction Manual B0700BM for limits. IEC 61000-4-6 Immunity to Conducted Disturbances Induced by Radio Fieldbus Communication Frequency Fields Communicates with its associated FCM10 or 10 V (rms) at 150 kHz to 80 MHz on I/O, dc FCM100 type, or FCP270 via the redundant 2 Mbps power and communication lines module Fieldbus IEC 61000-4-8 Power Frequency Magnetic Field Immunity Power Requirements 30 A/m at 50 and 60 Hz INPUT VOLTAGE RANGE (REDUNDANT) See FBM specification and the Table 2 on page 14 CONSUMPTION See FBM and HiD specification HEAT DISSIPATION See FBM and HiD specification
  • PSS 21H-2Y12 B4 Page 6 F U NCT ION A L S PE C IF I C ATI ON S ( C ON TI NU ED ) PRODUCT SAFETY Installation of ISTA-*BP* within a Installation of ISTA-*BP* in a General- Hazardous Classified Location Purpose (Unclassified) Area European Directive ISTA-*BP* baseplates are designed for ATEX Examination Certificate number: protection class IP20 in accordance with EN CESI 02 ATEX 086. 60529 and must accordingly be protected EC-Type Examination Certificate, against adverse ambient conditions such as Declaration of Conformity and water splashing or dirt. instructions have to be observed. Regardless of the ignition protection class of The ATEX Examination Certificate can be the HiD Modules that are fitted, intrinsically found under safe circuits of mounting plate ISTA-*BP* www.pepperl-fuchs.com. (light blue marking) can be routed into Classified Locations: hazardous areas. Special care must be taken Category 3 (Zone 2) in this case to ensure reliable separation Directives for U.S. and Canada from all non-intrinsically safe circuits. The CSA Examination Certificate number: installation of the intrinsically safe circuits is 1545160 (LR 66529-18). to be conducted in accordance with the CSA Examination Certificate have to be relevant installation regulations. observed for installation of ISTA-*BP* The corresponding entity parameters for the within a Hazardous Classified Location. field devices and the isolated modules Certified according CSA and US associated with it as defined for the purpose standards for the following Hazardous of explosion protection must be observed Classified Locations: when interconnecting intrinsically safe field - Class I, Division 2, Groups A, B, C and devices with the intrinsically safe circuits of D; T4 @ + 60 °C ISTA-*BP* mounting plates (proof of intrinsic - Class I, Zone 2, Ex nA IIC T4; safety). EN 60079-14/IEC 60079-14 or NEC Ta = 60°C 500 should be observed in this regard. For - Class I, Zone 2, AEx nA IIC T4; the Federal Republic of Germany, the Ta = 60°C National Foreword of DIN EN 60079-14/VDE The CSA Examination Certificate can be 0165 Part 1 must also be observed. found under www.pepperl-fuchs.com. When using intrinsically safe circuits in Calibration Requirements hazardous dust areas, only field devices Calibration of the module or termination certified for this purpose may be used. EC assembly is not required. Type Examination Certificate of conformity Additional Regulatory must be observed. It is especially important The ISTA-*BP* and the corresponding FBMs to maintain any special conditions that may must only be used in Zone 2. be indicated. For additional information, please refer to the CE Marking individual data sheets for the ISTA-*BP* For further information please refer to mounting plate and the related HiD2000 www.pepperl-fuchs.com. Modules (see www.pepperl-fuchs.com) and the FBM Product Specification Sheets. The devices should be installed in an enclosure to IP54 or better, in accordance with EN 60529. An explanation of the IP code is in the ISA-S71.04-1985 document.
  • PSS 21H-2Y12 B4 Page 7 E N V I R O N M E N TAL S P E C I F I C AT I O N S Operating Storage TEMPERATURE TEMPERATURE HiD Module and Baseplate HiD Module and Baseplate 0 to 60 °C (-32 to +140°F) -20 to +70°C (-4 to +158°F) RELATIVE HUMIDITY RELATIVE HUMIDITY HiD Module and Baseplate HiD Module and Baseplate 5 to 90% (non-condensing) 5 to 90% (non-condensing) The modules are intended for Installation The modules are intended for Installation Category II, Pollution Degree 2 as defined in Category II, Pollution Degree 2 as defined in IEC 664-1. IEC 664-1. VIBRATION VIBRATION HiD Module and Baseplate HiD Module and Baseplate The vibration specification for the DIN rail The vibration specification for the DIN rail mounted FBM subsystem modules is 0.75 g mounted FBM subsystem modules is 0.75 g (at 5 to 200 Hz) or 1 g (58 to 150 Hz) as (at 5 to 200 Hz) or 1 g (58 to 150 Hz) as defined in IEC 60068-2-x. defined in IEC 60068-2-x. The shock resistance of the interface board The shock resistance of the interface board is 15G, 11 ms (currentless state, sinusoidal is 15G, 11 ms (currentless state, sinusoidal half cycle) in acc. with IEC 60068-2-27. half cycle) in acc. with IEC 60068-2-27. CONTAMINATION CONTAMINATION HiD Module and Baseplate HiD Module and Baseplate The modules are intended for Installation Suitable for use in Class G3 (Harsh) Category II, Pollution Degree 2 as defined in environments as defined in ISA Standard IEC 664-1. S71.04, based on exposure testing according to EIA Standard 364-65, Class III.
  • PSS 21H-2Y12 B4 Page 8 P H Y S I C A L S P E C I F I C AT I O N S Mounting FIELD SIDE ISTA-*BP* Three tier terminal connection for field I/O ISTA-*BP* can be mounted on a DIN rail POWER SUPPLY (horizontally or vertically). Refer to B0700BM for Two primary and two Secondary power supply details. connections - three pin plugs with screw terminals Mass HART MULTIPLEXER FIELDBUS MODULE Connection to Pepperl+Fuchs Multiplexer type 284 g (10 oz) approximate MUX2700 G using a 37-pin Sub-D-connector ISTA-*BP* (WITH 8 MOUNTED HID MODULES AND WITHOUT FBMS) Terminal Blocks 3 rows, 8 positions Single 1860 g (4.1 lb) approximate Construction - Termination Assembly Dual or Redundant MATERIAL 2100 g (4.63 lb) approximate HiD Module Dimensions PC ISTA-*BP* (WITH 8 MOUNTED HID MODULES AND Baseplate WITHOUT FBMS) PC and ABS, inflammability UL94 V0 Height COLOR 153 mm (6 in) HiD Module Width Green Single Baseplate 175 mm (6.9 in) Black Dual / Redundant Field Termination Connections 242 mm (9.5 in) COMPRESSION-TYPE ACCEPTED WIRING SIZES Depth 254 mm (10 in) Solid/Stranded/AWG 0.2 to 4 mm² / 0.2 to 2.5 mm² / 24 to 12 Cable Connection AWG All required connections to I/A Series Fieldbus and to the field I/O are placed on the baseplate. The ISTA- *BP* also supports daisy-chain for power- and I/A Series Fieldbus-connection. DCS SIDE DCS connection using a 9-pin Sub-D connector Fault Output connection - three pin plug with screw terminals
  • PSS 21H-2Y12 B4 Page 9 ISTA-*BP* VERSIONS • YY: Function - such as: The ISTA*-BP* are fitted with eight HiD2000 Modules AI - Analog Input matching the respective FBM type. AO - Analog Output AIO - Analog Input / Analog Output ISTA-*BP* MARKING DI - Discrete Input The marking that identifies ISTA-*BP* is broken down DO - Discrete Output as follows: DIO - Discrete Input / Discrete Output HART - HART devices ISTA-2XXx-BPYY-(VV)-Z TI - Temperature Input Where: TIO - Temperature Input / Analog Output • 2XXx: FBM number - example FBM207b • VV: FD for fault detection (only if HiD2000 Module supports the function) 3W for 3-wire transmitter • Z: R for redundant (two FBMs); D for dual (two FBMs) Table 1. ISTA-*BP* Versions FBM Type ISTA-*BP* P/N ISTA-*BP* Name ISTA-*BP* Description FBM201 ISTA-201-BPAI-FD - 4 to 20 mA Input Interface Board, ISTA-201-BPAI-FD is fitted with 124885 HART-Compatible, Line Fault Detection eight 1-channel HiD2029 modules. ISTA-201-BPTI - RTD/Thermocouple/mV Interface ISTA-201-BPTI is fitted with eight 124886 Board 2-channel HiD2082 modules and prepared for mounting a FBM201 module. ISTA-201-BPAI - 4 to 20 mA Input Interface Board, ISTA-201-BPAI is fitted with eight 124884 HART-Compatible 1-channel HiD2025 modules. ISTA-201-BPAI-D - 4 to 20 mA Input Interface Board, ISTA-201-BPAI-D is fitted with 130211 HART-Compatible eight 2-channel HiD2026 modules and prepared for mounting two FBM201 modules. ISTA-201-BPAI-FD-D - 4 to 20 mA Input Interface Board, ISTA-201-BPAI-FD-D is fitted with 130212 HART-Compatible, Line Fault Detection eight 2-channel HiD2030 modules and prepared for mounting two FBM201 modules.
  • PSS 21H-2Y12 B4 Page 10 Table 1. ISTA-*BP* Versions (Continued) FBM Type ISTA-*BP* P/N ISTA-*BP* Name ISTA-*BP* Description ISTA-201-BPTI-D - RTD/Thermocouple/mV Interface ISTA-201-BPTI-D is fitted with 130213 Board eight 2-channel HiD2082 modules and prepared for mounting two FBM201 modules. FBM204 ISTA-204-BPAIO - 4 to 20 mA I/0 Interface Board, HART- ISTA-204-BPAIO is fitted with four 124887 Compatible 1-channel HiD2025 modules and four 1-channel HiD2031 modules. It is prepared for mounting a FBM204 module. ISTA-204-BPAIO-FD - 4 to 20 mA I/0 Interface Board, Line ISTA-204-BPAIO-FD is fitted with 124888 Fault Detection, HART-Compatible four 1-channel HiD2025 modules and four 1-channel HiD2037 modules. It is prepared for mounting a FBM204 module. ISTA-204-BPTIO - RTD/Thermocouple/mV Input, 4 to 20 ISTA-204-BPTIO is fitted with four 124889 mA Output Interface Board 1-channel HiD2031 modules and four 2-channel HiD2082 modules and prepared for mounting a FBM204 module. ISTA-204-BPTIO-FD - RTD/thermocouple/mV Input, 4 to 20 ISTA-204-BPTIO-FD is fitted with 124890 mA Output Interface Board, HART- four 1-channel HiD2037 modules Compatible, Line Fault Detection and four 2-channel HiD2082 modules. It is prepared for mounting a FBM204 module. ISTA-204-BPAIO-D - 4 to 20 mA I/O Interface Board, HART- ISTA-204-BPAIO-D is fitted with 130214 Compatible four 2-channel HiD2026 modules and four 2-channel HiD2032 modules. It is prepared for mounting two FBM204 modules. ISTA-204-BPAIO-FD-D 4 to 20 mA I/O Interface Board, HART- ISTA-204-BPAIO-FD-D is fitted - 130215 Compatible, Line Fault Detection with four 2-channel HiD2026 modules and four 2-channel HiD2038 modules. It is prepared for mounting two FBM204 modules.
  • PSS 21H-2Y12 B4 Page 11 Table 1. ISTA-*BP* Versions (Continued) FBM Type ISTA-*BP* P/N ISTA-*BP* Name ISTA-*BP* Description ISTA-204-BPTIO-D - RTD/Thermocouple/mV Input, 4 to 20 ISTA-204-BPTIO-D is fitted with 130216 mA Output Interface Board four 2-channel HiD2032 modules and four 2-channel HiD2082 modules. It is prepared for mounting two FBM204 modules. ISTA-204-BPTIO-FD- RTD/Thermocouple/mV Input, 4 to 20 ISTA-204-BPTIO-FD-D is fitted D - 130217 mA Output Interface Board, HART- with four 2-channel HiD2038 Compatible, Line Fault Detection modules and four 2-channel HiD2082 modules. It is prepared for mounting two FBM204 modules. FBM207b ISTA-207b-BPDI-FD - Voltage Monitor/Contact Sense Input ISTA-207b-BPDI-FD is fitted with 124893 Interface Board eight 2-channel HiD2822 modules. FBM211 ISTA-211-BPAI - 4 to 20 mA Input Interface Board, ISTA-211-BPAI is fitted with eight 124894 HART-Compatible 2-channel HiD2026 modules and prepared for mounting a FBM211 module. ISTA-211-BPAI-3W - 4 to 20 mA Input Interface Board, ISTA-211-BPAI-3W is fitted with 124895 HART-Compatible eight 2-channel HiD2030 modules. ISTA-211-BPTI - RTD/Thermocouple/mV Input Interface ISTA-211-BPTI is fitted with eight 124896 Board 2-channel HiD2082 modules and prepared for mounting a FBM211 module. FBM214 ISTA-214-BPHI - HART-Communication, 4 to 20 mA ISTA-214-BPHI is fitted with eight 124897 Input Interface Board 1-channel HiD2025 modules and prepared for mounting a FBM214 module. ISTA-214-BPHI-FD - HART-Communication, 4 to 20 mA ISTA-214-BPHI-FD is fitted eight 124898 Input Interface Board, Line Fault 1-channel HiD2029 modules and Detection prepared for mounting a FBM214 module.
  • PSS 21H-2Y12 B4 Page 12 Table 1. ISTA-*BP* Versions (Continued) FBM Type ISTA-*BP* P/N ISTA-*BP* Name ISTA-*BP* Description ISTA-214-BPHI-D - HART-Communication, 4 to 20 mA ISTA-214-BPHI-D is fitted with 132950 Input Interface Board eight 2-channel HiD2026 modules and prepared for mounting two FBM214 modules. ISTA-214-BPHI-FD-D HART-Communication, 4 to 20 mA ISTA-214-BPHI-D is fitted with - 180257 Input Interface Board, Line Fault eight 2-channel HiD2030 modules Detection and prepared for mounting two FBM214 modules. FBM215 ISTA-215-BPHO-FD - HART Communication 4 to 20 mA ISTA-215-BPHO-FD is fitted with 124899 Output Interface Board, Line Fault eight 1-channel HiD2037 modules Detection and prepared for mounting a FBM215 module. ISTA-215-BPHO-FD-D HART-Communication, 4 to 20 mA ISTA-215-BPHO-FD-D is fitted - 189669 Output Interface Board, Line Fault with eight 2-channel HiD2038 Detection modules and prepared for mounting two FBM215 modules. FBM216 ISTA-216-BPHI-R - Redundant 4 to 20 mA Input Interface ISTA-216-BPHI-R is fitted with 124900 Board, HART Communication eight 1-channel HiD2025 modules and prepared for mounting two FBM216 modules. ISTA-216-BPHI-FD-R Redundant 4 to 20 mA Input Interface ISTA-216-BPHI-FD-R is fitted with - 124901 Board, HART Communication, Line eight 1-channel HiD2029 modules Fault Detection and prepared for mounting two FBM216 modules. FBM217 ISTA-217-BPDI-FD - Discrete Input Interface Board, Line ISTA-217-BPDI-FD is fitted with 124902 Fault Detection eight 4-channel HiD2844 modules and prepared for mounting a FBM217 module. ISTA-218-BPHO-FD-R Redundant 4 to 20 mA Output ISTA-218-BPHO-FD-R is fitted - 124903 Interface Board, HART with eight 1-channel HiD2037 Communication, Line Fault Detection modules and prepared for mounting two FBM218 modules.
  • PSS 21H-2Y12 B4 Page 13 Table 1. ISTA-*BP* Versions (Continued) FBM Type ISTA-*BP* P/N ISTA-*BP* Name ISTA-*BP* Description FBM237 ISTA-237-BPAO - 4 to 20 mA Output Interface Board ISTA-237-BPAO is fitted with eight 124904 1-channel HiD2031 modules and prepared for mounting a FBM237 module. ISTA-237-BPAO-FD - 4 to 20 mA Output Interface Board, ISTA-237-BPAO-FD is fitted with 124905 HART-Compatible, Line Fault Detection eight 1-channel HiD2037 modules and prepared for mounting a FBM237 module. ISTA-237-BPAO-R - Redundant 4 to 20 mA Output ISTA-237-BPAO-R is fitted with 124906 Interface Board eight 1-channel HiD2031 modules and prepared for mounting two FBM237 modules. ISTA-237-BPAO-FD-R Redundant 4 to 20 mA Output ISTA-237-BPAO-FD is fitted with - 124907 Interface Board, Line Fault Detection, eight 1-channel HiD2037 modules HART-Compatible and prepared for mounting two FBM237 modules. FBM241c ISTA-241c-BPDIO - Discrete I/O Interface Board ISTA-241c-BPDIO is fitted with 190850 four 2-channel HiD2822 modules and four 2-channel HiD2872 modules and prepared for mounting a FBM241c module. ISTA-241c-BPDIO-FD Discrete I/O Interface Board, Line Fault ISTA-241c-BPDIO-FD is fitted with - 124909 Detection four 2-channel HiD2822 modules and four 2-channel HiD2874 modules and prepared for mounting a FBM241c module. FBM242 ISTA-242-BPDO - Externally Sourced Discrete Output ISTA-242-BPDO is fitted with eight 180222 Interface Board 2-channel HiD2876 modules and prepared for mounting a FBM242 module. ISTA-242-BPDO-FD - Externally Sourced Discrete Output ISTA-242-BPDO-FD is fitted with 124910 Interface Board, Line Fault Detection eight 2-channel HiD2874 modules and prepared for mounting a FBM242 module.
  • PSS 21H-2Y12 B4 Page 14 HID PROPERTIES AND ISTA-*BP* APPLICATIONS The colored background of the following table indicates a circuit, running in a hazardous area. Table 2. HiD Basic Properties HiD Signal Inputs Signal Outputs Module Number ISTA-*BP* HART transmitter power HiD2025 8 ISTA-201-BPAI supply 4 ISTA-204-BPAIO 4 4 - 20 mA 4 - 20 mA 8 ISTA-204-BPAIO-FD 8 ISTA-214-BPHI ISTA-216-BPHI-R HART transmitter power HiD2026 8 ISTA-211-BPAI supply 2-channel 8 ISTA-201-BPAI-D 4 4 - 20 mA 4 - 20 mA ISTA-204-BPAIO-D 4 8 ISTA-204-BPAIO-FD-D ISTA-214-BPHI-D HART transmitter power HiD2029 8 ISTA-201-BPAI-FD supply/current repeater 8 ISTA-214-BPHI-FD 8 4 - 20 mA 4 - 20 mA ISTA-216-BPHI-FD-R HART transmitter power HiD2030 8 ISTA-211-BPAI-3W supply/current repeater 2-channel 8 ISTA-201-BPAI-FD-D 8 4 - 20 mA 4 - 20 mA ISTA-214-BPHI-FD-D Isolated output current HiD2031 4 ISTA-204-BPAIO driver 4 ISTA-204-BPTIO 8 4 - 20 mA 4 - 20 mA 8 ISTA-237-BPAO ISTA-237-BPAO-R Isolated output current HiD2032 4 ISTA-204-BPAIO-D driver 4 2-channel ISTA-204-BPTIO-D 4 - 20 mA 4 - 20 mA
  • PSS 21H-2Y12 B4 Page 15 Table 2. HiD Basic Properties (Continued) HiD Signal Inputs Signal Outputs Module Number ISTA-*BP* HART isolated output HiD2037 4 ISTA-204-BPAIO-FD current driver 4 ISTA-204-BPTIO-FD 8 4 - 20 mA 4 - 20 mA 8 ISTA-215-BPHO-FD 8 ISTA-237-BPAO-FD 8 ISTA-218-BPHO-FD-R ISTA-237-BPAO-FD-R HART isolated output HiD2038 4 ISTA-204-BPAIO-FD-D current driver 2-channel 4 ISTA-204-BPTIO-FD-D 8 4 - 20 mA 4 - 20 mA ISTA-215-BPHO-FD-D Converter for RTD, 4 - 20 mA HiD2082 8 ISTA-201-BPTI potentiometer, 2-channel 4 ISTA-204-BPTIO thermocouples and mV 4 signals 8 ISTA-204-BPTIO-FD 8 ISTA-211-BPTI 4 ISTA-201-BPTI-D 4 ISTA-204-BPTIO-D ISTA-204-BPTIO-FD-D Switch amplifier for proximity Relay HiD2822 8 ISTA-207b-BPDI-FD switches or mech. contacts 2-channel 4 ISTA-241c-BPDIO-FD 4 ISTA-241c-BPDIO Switch amplifier or proximity Open collector output HiD 2844 8 ISTA-217-BPDI-FD switches or mech. contacts 4-channel Mech. contact or open Solenoid/Alarm Driver HiD2872 4 ISTA-241c-BPDIO collector 2-channel Mech. contact or open Solenoid/Alarm Driver HiD2874 4 ISTA-241c-BPDIO-FD collector 8 2-channel ISTA-242-BPDO-FD Mech. contact or open Solenoid/Alarm Driver HiD2876 8 ISTA-242-BPDO collector 2-channel D I M EN SI O N S - NO M I NA L
  • PSS 21H-2Y12 B4 Page 16 Dimensions of a Single Version ISTA-*BP* Dimensions of Dual or Redundant Version (H/W/D) 153 mm (6.0 in), 175 mm (6.9 in), 254 mm ISTA-*BP* (10.0 in) (H/W/D) 153 mm (6.0 in), 242 mm (9.5 in), 254 mm (10.0 in) FOR MORE INFORMATION For more information, refer to the following documentation: Document Title Document Number DIN Rail Mounted Subsystem Overview PSS 21H-2W1 B3 DIN Rail Mounted FBM Equipment, Agency PSS 21H-2W2 B3 Certification DIN Rail Mounted Modular Baseplates PSS 21H-2W6 B4 Environmental Conditions for Process Measurement ISA-S71.04-1985 (not Invensys-supplied) and Control Systems: Airborne Contaminants I/A Series® System ISTA-*BP* Instruction Manual B0700BM (available from Pepperl+Fuchs and Foxboro) 33 Commercial Street Invensys, Foxboro, and I/A Series are trademarks of Invensys plc, its Foxboro, MA 02035-2099 subsidiaries, and affiliates. United States of America All other brand names may be trademarks of their respective owners. www.foxboro.com Inside U.S.: 1-866-746-6477 Outside U.S.: 1-508-549-2424 Copyright 2007 Invensys Systems, Inc. or contact your local Foxboro All rights reserved representative. Facsimile: 1-508-549-4999 MB 21A Printed in U.S.A. 0807