• Share
  • Email
  • Embed
  • Like
  • Save
  • Private Content
Avanceon's Energy Management Solutions at work at Engro Fertilizer
 

Avanceon's Energy Management Solutions at work at Engro Fertilizer

on

  • 1,292 views

 

Statistics

Views

Total Views
1,292
Views on SlideShare
1,284
Embed Views
8

Actions

Likes
0
Downloads
0
Comments
0

1 Embed 8

http://www.avanceon.com 8

Accessibility

Categories

Upload Details

Uploaded via as Microsoft PowerPoint

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

    Avanceon's Energy Management Solutions at work at Engro Fertilizer Avanceon's Energy Management Solutions at work at Engro Fertilizer Presentation Transcript

      • ENERGY MANAGEMENT SOLUTION
      • (EMS)
      ENGRO CHEMICAL PAKISTAN LIMITED Technical Department – D A H A R K I JW May 18, 2009 We do not inherit the earth from our ancestors, we borrow it from our children.
    • A Success Story & TEAM WORK DIVIDES TASK & MULTIPLIES SUCCESS
    • OVERVIEW
      • In the present competitive business environment, Energy Footprint reduction is considered the most viable and imperative strategy.
      • The biggest challenge however is to ensure that the return estimated during project inception and approval are guaranteed and maintainable.
      • The task was collectively taken up by E-Fert and AVANCEON teams for implementing Energy Saving Solution on water applications.
      • The unique feature of the proposal is AVANCEON’s Energy Savings Guarantee with absolutely no financial risk of payback variation to E-Fert
    • CONCEPT OF iwater EMS?
      • Simple concept of Demand based Supply Management, AVENCEON provided complete engineering solution on turn-key basis.
      • Traditionally flow & pressure is controlled at pump discharge by valves throttling.
      • Valve throttling causes loss of energy hence is an in-efficient way of operation.
      • The modern way is to control parameters fluctuation by varying speed of the pumps.
      • Variable Frequency Drives (VFDs) are installed on the motors of pumps for this purpose.
      • AVANCEON’s patented iwater TM software package provides deep insight in operation especially the savings profile on LAN / WAN.
    • System Architecture:
    • Project Basis:
      • A joint study carried out by ENGRO-Fertilizer & AVANCEON to find out potential energy saving.
      • 10 pumps were identified at site for Energy Management Solutions. 06 were related to Cooling Water Circuit.
      • Replacement of existing motors with new inverter duty energy efficient motors
      • Provision of respective hardware (instrumentation / control logics etc.) for reliable operation
      • Necessary changes in Electrical systems to meet the overall requirement of proposed system
      • Energy Partnership Contract of the Project was awarded to AVANCEON.
      • Project Cost = 74.4 M IRR = 20 % Annual Saving = 17.4 M
    • ENERGY BENEFITS
      • Energy survey was carried out and data recorded prior to execution of project.
      • Extensive Electrical /Mechanical & Civil work done for completion of project.
      • MV & LV motors successfully commissioned last year.
      • Post commissioning energy survey carried out on and saving found as below:
        • Annual Saving of ~20.5 M vs 17.4 M (Planned) with old price while ~30 M with new energy price
        • Pay back period of 3.6 year vs. 4.5 year (Planned) while 2.5 Years with new energy price
        • Actual IRR 40% vs 20 % (Planned) - New and old energy price
    • COOLING WATER IN PLANTS IS LIKE BLOOD IN OUR BODY ADDITIONAL BENIFITS
    • Additional Benefits:
      • Main focus of Project was on areas, where motors were limiting cooling water flow.
      • About 15% increase in cooling water flow at Urea, resulting.
        • Reduction in NH 3 losses at Urea plants due to increased CW flow .
        • Improved plant load of Urea-1 in summer
      • Reduction in power load of around 1 MW, enabled two GT’s operation instead three GT operation in Peak Summer.
      • Very much operator friendly operation.
      • Easy & reliable emergency handling
      • Smooth pumps startup due to soft starting feature of VFDs
      • Lesser initial torque on motor so reduction in pumps wear tear
    • Ongoing Projects (2010):
      • Iboiler project being engineered, guranteeing steam cost reduction by 3-5 % .
        • Estimated savings of PKR 20 M per year
        • Three boilers each with 25 TPH capacity, Fuel used are natural gas and purge gas (by product of fertilizer process)
        • Payments: 6 months of proven saving and monthly Managed service level agreement fee
    • Future Prospects:
      • Other applications are still under consideration to replicate this successfully proven energy efficient solution all over the site.
      • Potential saving of about twice the earleir saving exist.
      • Iboiler being installed.