The Complete Power Monitoring   & Management System for Data Centres                                          1
What We OfferStratergia has developed software to monitor powerconsumption at the application level within servers. Itallo...
Company Background•  Company based in Eastpoint Business Park, Dublin, with researchcentres in Ireland, Austria and Sweden...
PAPILLON – what it doesPAPILLON is a unique, innovative and comprehensive powermanagement system.•  It measures server-lev...
UniquenessIt’s equivalent to having a Virtual Meter on everysingle server, creating a comprehensive, accurateand integrabl...
UniquenessPAPILLON is accurate to within 1% of metered measurements                                                       ...
Uniqueness PAPILLON delivers real-time power visibilityServerPowerTrace                                                7
PAPILLON is agent implemented and non-intrusive                                              Agent monitor     Client     ...
It permits Feedback for policy control    CorporateRequirements/StrategyPolicy/Costs               Control:               ...
PAPILLON Data Centre/Client Benefits•  Accurate strategic analysis of data centre performance, leading tomore efficient ca...
Potential SavingsAn average server consumes 750w/hr. At €0.12 per kWH = €800 per yearPapillon software offers a Payback pe...
PAPILLON: InstallationAgents self-install over TCP-IP. System remains fully operational duringagent installation.         ...
PAPILLON: Real Time Operation      Agents wake periodically and observe pertinent system      parameters. Each agent trans...
14
Server Power Trace                     Same application                     running on two                     different s...
Server Power Threshold Analysis                                  16
Weather Map              17
Thank youFurther informationTo arrange an online demo or system trial, please contact:colm.doherty@stratergia.comStratergi...
Upcoming SlideShare
Loading in...5
×

Papillon v4 2

215

Published on

Published in: Technology
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
215
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
1
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Papillon v4 2

  1. 1. The Complete Power Monitoring & Management System for Data Centres 1
  2. 2. What We OfferStratergia has developed software to monitor powerconsumption at the application level within servers. Itallows Data Centres reduce server power consumptionby up to 35% 2
  3. 3. Company Background•  Company based in Eastpoint Business Park, Dublin, with researchcentres in Ireland, Austria and Sweden•  Development capability of post-graduate and doctorate teams from University College Dublin, Technical University Graz and the University of Linköping, Sweden•  Technology developed in collaboration with Compare Test lab, Karlstad, centre of excellence in data centre innovation•  Team holds 11 international patents in products and techniques and collectively published over 100 IEEE and ACM peer reviewed research and technical papers, in the areas of advanced processor design, RFID and System-level power analysis tools 3
  4. 4. PAPILLON – what it doesPAPILLON is a unique, innovative and comprehensive powermanagement system.•  It measures server-level & application power usage in real-time•  It has no requirement of any additional hardware (e.g. meters)•  It is simple and intuitive to use, operates in Windows, Unix/Linux.•  It is readily and quickly installed (hours). 4
  5. 5. UniquenessIt’s equivalent to having a Virtual Meter on everysingle server, creating a comprehensive, accurateand integrable power monitoring system, requiringno physical installation and consuming no power. 5
  6. 6. UniquenessPAPILLON is accurate to within 1% of metered measurements 6
  7. 7. Uniqueness PAPILLON delivers real-time power visibilityServerPowerTrace 7
  8. 8. PAPILLON is agent implemented and non-intrusive Agent monitor Client Client Power data Packet Network Power Model D/base Master ServerClient Client 8
  9. 9. It permits Feedback for policy control CorporateRequirements/StrategyPolicy/Costs Control: Cooling Power Metrics/ Demand Data-Centre Measurement QoS Environment Virtualisation Scheduling Provisioning Capital Exp. Clients/Users 9
  10. 10. PAPILLON Data Centre/Client Benefits•  Accurate strategic analysis of data centre performance, leading tomore efficient capital expenditure and operating cost control•  Inform decision making for policy/strategy decisions, purchasingand optimal provisioning, and chargeback of resources•  No Hardware costs•  Balance power demand and identify hot-spots in real-time•  Identify inactive servers to be powered down – saving up to 90%•  Application usage can be monitored on an enterprise wide basis•  Applications can run on more efficient hardware – saving up to 35%•  Increase in server utilisation from typical 10-20% (IDC) to 80% 10
  11. 11. Potential SavingsAn average server consumes 750w/hr. At €0.12 per kWH = €800 per yearPapillon software offers a Payback period of 2-4 months Direct Annual Saving € No of Servers Savings @ 20% Savings @ 30% 1,000 € 160,000 € 240,000 3,000 € 480,000 € 720,000 5,000 € 800,000 € 1,200,000 10,000 € 1,600,000 € 2,400,000 30,000 € 4,800,000 € 7,200,000 NB: Equal savings can be made in Indirect expenses due to lower cooling and ancilliary costs 11
  12. 12. PAPILLON: InstallationAgents self-install over TCP-IP. System remains fully operational duringagent installation. Agents are dormant for 99.9% of the time. At regular intervals each agent on a Client server will awake and read various O/S parameters. Client Network Transmit Monitor Agents Master Server Agents only read various O/S Client parameters and only write information Agents are Client into TCP/IP packets installed once Agents do not need any special privileges. from the master They operate in normal ‘user mode’. They using the TCP/IP pose no security risk beyond any normal network 12 process.
  13. 13. PAPILLON: Real Time Operation Agents wake periodically and observe pertinent system parameters. Each agent transmits packets containing parameter data. Client Client Network TCP/IP O/S Parameter Data Packets Power Model D/base Master Server Client The master accesses the appropriate power Client model for each client . With each clients data it computes its power consumption. All power Clients and servers use a REST (Representational State computation and database storage is done by the Transfer) protocol. This gives great portablity. master.. 13
  14. 14. 14
  15. 15. Server Power Trace Same application running on two different servers 15
  16. 16. Server Power Threshold Analysis 16
  17. 17. Weather Map 17
  18. 18. Thank youFurther informationTo arrange an online demo or system trial, please contact:colm.doherty@stratergia.comStratergia Group Sales,Innovation House,East Point Business Park,Dublin 3,Ireland.Tel: +353 86 4029776www.stratergia.com 18
  1. A particular slide catching your eye?