AirRevive offers a guestroom fan coil refurbishment and re-commissioning service for hotels that improves indoor air quality, reduces energy usage, and extends the life of fan coil units. The multi-step process includes cleaning and disinfecting coils and components, replacing worn parts, upgrading to eco-friendly insulation and motors, and reprogramming airflow. Retrofitting units with electronically commutated motors can reduce energy usage by up to 80% while improving guest comfort with less noise and more accurate temperature control. The service aims to enhance sustainability, lower operating costs, and complement room renovations.
3. Chemistry
AirRevive is proud to be the service provider for
ChemTron International and its services are Avendra
approved.
3
Airrevive.com 954-660-2300
4. People
Hospitality is our
business!
Technicians are trained
to work in operating
hotels and renovations.
Lead technicians are
HVAC certified
AirRevive benefits from
25+ years experience in
air conditioning
4
6. Turnkey Service
6
AirRevive's consulting services
include a site inspection, survey, and
energy calculations.
The service includes labor, proprietary
chemical solutions, parts upgrades
and project management.
AirRevive can be worked into re-
commissioning projects, renovations,
and operating environments.
Airrevive.com 954-660-2300
8. Guestroom Fan Coil
Refurbishment
AirRevive’s fan coil
refurbishment service is a
green process that improves
indoor air quality, reduces
energy usage, and extends
the life of fan coil unit.
8
Airrevive.com 954-660-2300
12. 12
Recondition the
blower assembly
Purpose: Improve the fan motor’s
performance and reduce energy
consumption.
Improve guestroom indoor air quality.
Airrevive.com 954-660-2300
14. 14
Refurbish the
condensate pan
Purpose: Stop pan from rusting.
Clean and disinfect.
Epoxy coating creates an impermeable surface that
protects and seals the drain pan from leaks and
enhances water flow drainage.
Cant find a decent after
pan photo that would somewhat matches
15. Clear the drain lines
15
Purpose: Clear out drain lines
for proper drainage.
Disinfect drain lines to
eliminate bacteria and mal
odors.
Goodbye Bacteria!
16. Replace fiber insulation with
fiber-free foam anti-microbial
thermal insulation
16
Purpose: Improve indoor air
quality and reduce noise.
Fiber-free foam insulation is
mold and mildew resistant.
The foam insulation reduces
fan motor noise.
17. 17
Purpose: Improve indoor air
quality and reduce noise.
Fiber-free foam insulation is
mold and mildew resistant.
The foam insulation reduces
fan motor noise.
The foam insulation
improves airflow.
Eliminate bacteria living in
fiber insulation.
Eliminate fiber from
getting stuck in the coil
and floating in the air.
Eliminate allergens
caused by fiber insulation.
18. Replace isolation and
control valve
18
Purpose: Improve indoor air
quality and reduce noise.
Fiber-free foam insulation is
mold and mildew resistant.
The foam insulation reduces
fan motor noise.
Purpose:
Stop leaks to save
energy and make the
unit more efficient.
Fix leaking control
valves that waste
energy.
Fix leaking control
valves that negatively
impact the HVAC
performance and
cause chiller energy
inefficiency.
19. Component
Retrofits
19
Purpose: Improve indoor air
quality and reduce noise.
Fiber-free foam insulation is
mold and mildew resistant.
The foam insulation reduces
fan motor noise.
Purpose:
Replace existing components with top of the line
equipment so that the refurbished fan coil unit is
superior to any off the shelf fan coil unit in the
marketplace.
20. Blower photo after
guestroom renovation.
20
Renovation?
Fan coil refurbishment
service complements a
rooms renovation.
Renovation dust takes years
off the life of the asset.
It adds allergens to the air.
Airrevive.com 954-660-2300
24. 24
AirRevive combines its fan coil
refurbishment process with EC
motor (ECM) installations to re-
commission hotel guestroom fan coil
units.
Utilizing EC motors, the airflow is
programmed specifically to the fan
coil unit’s manufacturer’s
specifications.
The result is a re-commissioned unit.
EC motor Retrofit Best
Practice
25. 25
Fan coils are often overlooked
during building sustainability
projects because of their fractional
horsepower and low power
consumption.
Upgrading PSC motors to EC
motors, however, allows cost
effective energy savings satisfying
green building initiatives.
EC MOTORS AND
BUILDING
SUSTAINABILITY
26. EC MOTOR RETROFIT
REDUCES GUESTROOM FAN
COIL ENERGY USAGE
UP TO 80%
That’s about 20% reduction in energy
spend for the building
Results are consistent…..
Airrevive.com 954-660-2300
28. Guest Comfort Benefits
Significant noise reduction
Room cools faster
Dry air - reduced humidity
Accurate temperature set points
Eliminates A/C related mal
odors
29. Services also include:
Air Handler Maintenance
Chiller Plant Optimization
http://airrevive.com/hvacservices/chiller-plant-optimization/
29
Airrevive.com 954-660-2300