Solutions Using BusWorks Ethernet ModbusTCP/IP

1,235 views
1,005 views

Published on

Published in: Technology
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
1,235
On SlideShare
0
From Embeds
0
Number of Embeds
2
Actions
Shares
0
Downloads
8
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Solutions Using BusWorks Ethernet ModbusTCP/IP

  1. 1. BusWorks Ethernet Applications
  2. 2. Process control & monitoring of wastewater treatment filtration HEAD LOSS – The pressure or energy lost by water flowing in a pipe PARTICLE COUNTING – Counting and measuring the size of individual particles in water FLOW RATE TURBIDITY – A measure of the clarity of water from the presence of suspended matter Ethernet Modbus TCP/IP 961EN-4012 4-20 mA Inputs Modicon Quantum PLC H M I
  3. 3. Monitor opacity of exhaust gas from an Electrostatic Precipitator (ESP) Wonderware InTouch visualization software and historian 951EN-4012 Analog & Discrete Combo Optical Sensor: 4-20mA output proportional to the density of particles in the exhaust HMI Discrete Outputs for On/Off Control or Indication Ethernet Modbus TCP/IP Mitsubishi PLC
  4. 4. Monitoring molecular absorption of CO2 in high speed flow Sensor Management Station In-line Dissolved CO2 Sensor Ethernet Modbus TCP/IP 4-20 mA CO2 Pressure 951EN-4012 16 Bit Resolution Bottling Operations
  5. 5. Monitor diesel engine conditions of Gen-Set during peak power demands Coolant Level Coolant Temperature Oil Pressure Engine Overspeed / Underspeed Switch connected to Fuel Rack Solenoid GE PLC Ethernet Modbus TCP/IP Peak Load Base Load 1 MW Direct Fuel Cell Plant Natural Gas or Methane Gen-Set 250 KW 981EN-4012 966EN-4006 900EN-S005 Ethernet Switch Switches RTD
  6. 6. Freshwater monitoring over DSL from remote pumping station pH Chlorine Pressure Pumping Station A-B SLC 5/05 Ethernet / IP 961EN-6006 4-20 mA Inputs Citect SCADA Treatment Plant Verizon VPN DSL DSL Turbidity
  7. 7. Using telemetry to monitor water quality of river near gold mining operations 2 Miles Adroit SCADA Conductivity Flow Level Chemical 961EN-4012 4-20 mA Inputs Deepest Drop Single Shaft Gold Mine In The World Ethernet Modbus TCP/IP Ethernet WiFi 802.11b D-Link Ethernet to Wireless Bridge D-Link Ethernet to Wireless Bridge River Water
  8. 8. Using an OPC server to interface remote I/O with DeltaV and PI system OPC Server (OLE for Process Control) Emerson DeltaV Process Monitoring and Control OSIsoft PI System historian, spreadsheet and trending application s OPC Compliant Turbine Alternator Set RTD 966EN-4006 Fiber Optic Copper EIS-408FX-M 6 copper & 2 fiber ports Ethernet Modbus TCP/IP

×