Your SlideShare is downloading. ×
Plant Canopy Analyzer by ACMAS Technologies Pvt Ltd.
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×

Introducing the official SlideShare app

Stunning, full-screen experience for iPhone and Android

Text the download link to your phone

Standard text messaging rates apply

Plant Canopy Analyzer by ACMAS Technologies Pvt Ltd.

204
views

Published on

Weiber’s Plant Canopy Analyzer can be widely used in …

Weiber’s Plant Canopy Analyzer can be widely used in
agricultural production and agricultural research.

Published in: Technology, Business

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
204
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
4
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. R PLANT CANOPY ANALYZER MODEL NO. - ACM-PCA-2674
  • 2. R PLANT CANOPY ANALYZER MODEL NO. - ACM-PCA-2674 Weiber’s Plant Canopy Analyzer can be widely used in The band area can be used to quantify a variety of stress agricultural production and agricultural research. A total caused by differences in plant canopy emissivity. 750- of 17 road spectral information input, including the way 900 nm near-infrared bands to detect and assess the for environmental calibration optical path signal; with a severity of leaf diseases are very useful. Near infrared TFT color screen display interface, GPRS wireless region of the long-wave band can be used to estimate communication interfaces, GPS positioning interfaces. the biochemical composition of plants. Have any substance emission, absorption and Using visible / near-infrared reflectance spectroscopy reflection characteristics of electromagnetic waves, and multi-channel spectral information scanning which is the basic principle of detection of spectral technology to quickly determine the surface vegetation information. By measuring the absorption of radiation of parameters, plant canopy information, and information each wavelength, transmission or reflection properties on plant nutrients, soil nutrient information, of the substance can be identified. In practice, only need environmental parameters, plant pests and diseases to select certain bands to identify the characteristics of and so on. the selected material. The use of narrow-band filters to 8-channel general-purpose instrument for the detection select the visible and near-infrared (NIR) area of the spectrum analyzer, the largest of different bands can electromagnetic spectrum in certain bands. support 16 channels of general-purpose spectral TECHNOLOGIES PVT. LTD.
  • 3. R information collection instrument, the user can Ÿ Crop quality factor customize according to the actual needs of different Ÿ Leaf area index spectral bands of the filter test. Ÿ Because Instrument comes with 8-band filters, the main center band is: 550nm, 600nm, 650nm, 730nm, 940nm, 1100nm, 1250nm, 1550nm. Built-in sensor autocalibration module. of disease, air pollution, nutrient deficiencies and chemical plants and other toxins resulting from reduced crop yield and quality losses Ÿ Assessment of plant growth regulator Ÿ Objectively and effectively to various leaf disease rating Plant canopy Analyzer Applications Ÿ Monitoring the effect of application of herbicide Description: Ÿ Used for soil improvement and soil fertility research Ÿ The normal growth of plants Ÿ Foliar fertilization of Ÿ Plant canopy color Ÿ Study of Irrigation Scheduling Ÿ Plant growth environment Assessment: Ÿ Drought on plant growth and yield of Ÿ Biomass crop Ÿ Characteristics of different genotypes Ÿ Biochemical content Ÿ Test to assess the variation Ÿ Crop yield integral TECHNOLOGIES PVT. LTD.
  • 4. R information collection instrument, the user can Ÿ Crop quality factor customize according to the actual needs of different Ÿ Leaf area index spectral bands of the filter test. Ÿ Because Instrument comes with 8-band filters, the main center band is: 550nm, 600nm, 650nm, 730nm, 940nm, 1100nm, 1250nm, 1550nm. Built-in sensor autocalibration module. of disease, air pollution, nutrient deficiencies and chemical plants and other toxins resulting from reduced crop yield and quality losses Ÿ Assessment of plant growth regulator Ÿ Objectively and effectively to various leaf disease rating Plant canopy Analyzer Applications Ÿ Monitoring the effect of application of herbicide Description: Ÿ Used for soil improvement and soil fertility research Ÿ The normal growth of plants Ÿ Foliar fertilization of Ÿ Plant canopy color Ÿ Study of Irrigation Scheduling Ÿ Plant growth environment Assessment: Ÿ Drought on plant growth and yield of Ÿ Biomass crop Ÿ Characteristics of different genotypes Ÿ Biochemical content Ÿ Test to assess the variation Ÿ Crop yield integral TECHNOLOGIES PVT. LTD.
  • 5. R Plant canopy Analyzer Features the 360-degree adjustable, you can automatically calibrate the sun direction angle to the measurement of Ÿ INDVI, WDR-NDVI, RVI Ÿ Photochemical reflectance PRI the impact of Ÿ Leaf area index (LAI) Ÿ Instrument height can be adjusted Ÿ The proportion of canopy gap (GAP SIZE) Ÿ 8-band with the Landsat satellite thermal spectrum Ÿ Plant canopy absorbed photo synthetically active band diagram similar to the first eight radiation component (FPAR) Ÿ Light weight, easy to carry Ÿ Band: 8 Ÿ Can be used for unattended operation Ÿ Central Ÿ Chinese large-screen LCD display Ÿ Handset can store, through the key storage Ÿ With a computer interface, data can be imported computers, for analysis purposes wavelength: 550nm, 600nm, 650nm, 730nm, 940nm, 1100nm, 1250nm, 1550nm Ÿ Operating range: 0 to +50 ?, 0 Dao 100% RH non- condensing, "20% relative humidity storage Ÿ Reflectance range: 0 to 100% Technical Features Ÿ Resolution: 0.06% It is now scheduled for the subjects are: Ÿ Accuracy: + / -4% Ÿ Normalized difference vegetation index NDVI, SA- Ÿ Detector: light-emitting diodes TECHNOLOGIES PVT. LTD.
  • 6. An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485 WHO: GMP Products | GLP Compliant Products www.acmasindia.com | www.acmasglobal.com | www.measuring-meters.com TECHNOLOGIES PVT. LTD. CORPORATE OFFICE/ SHOWROOM (INDIA) Plot No. 352-353, Sector – 57 Phase- IV Kundli, Sonepat, Haryana - 131028 Land Line No.: +91 - 11- 47619688, Fax: +91-11-47619788 E-mail.: info@acmasindia.com SALES OFFICE (HONG KONG) Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East, Sheung Wan, Hong Kong (PRC) Tel.: 0086-13929598046 | 0086- 18922303099 E-mail.: hk@acmasindia.com SALES OFFICE (RUSSIA) Inmed Trade Street Ozerkovsky Embankment, Unit No 50, Straine- 1, Off- 502, Moscow, Russia E-mail.: info@acmasindia.com Tel.: 0049- 79592345 | Email: russia@acmasindia.com