Online pH Analyzer by ACMAS Technologies Pvt Ltd.

  • 67 views
Uploaded on

Online pH analyzer are most highly developed pH analyzer systems used in analytical and critical application such as power plants, process control applications, effluent treatment applications and …

Online pH analyzer are most highly developed pH analyzer systems used in analytical and critical application such as power plants, process control applications, effluent treatment applications and several other applications
involving research and analysis. Metal Finishing, Chemical process, Pharmaceutical production, Drug research and Fermentation.

More in: Technology
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Be the first to comment
    Be the first to like this
No Downloads

Views

Total Views
67
On Slideshare
0
From Embeds
0
Number of Embeds
0

Actions

Shares
Downloads
0
Comments
0
Likes
0

Embeds 0

No embeds

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
    No notes for slide

Transcript

  • 1. R ONLINE PH ANALYZER MODEL NO.- ACM-HK-328
  • 2. R ONLINE PH ANALYZER Online pH analyzer are most highly developed pH analyzer systems used in analytical and critical application such as power plants, process control applications, effluent treatment applications and several other applications involving research and analysis. Metal Finishing, Chemical process, Pharmaceutical production, Drug research and Fermentation. Measurement of COD in Ÿ Advanced embedded MCU technology. Ÿ SMT and integrative design to enhance the analyzer’s performance and dependability. Ÿ Display language can be set English./One Local. Ÿ It can achieve long distance transmission from the sensor to the transmitter. Ÿ You can see the pH changing trend directly according to the history curve. Ÿ Use the low resistance pH electrode which measuring fast and accurate. Ÿ All the operation and programming are controlled by 8 membrane keys. Ÿ The program function is protected by the protective passwords which protect the user’s setting. Ÿ It can connect to the other device directly with the communicating serial port. Ÿ Two isolated current output and alarm signal. Ÿ The transmitter case is made of ABS material and the interior shield layer that make the transmitter firm, smart. Ÿ Anti-static and easy installation. Ÿ Enquire a large part of operation conveniently in the log menu. Ÿ The membrane key has a longer using life. Ÿ Multi parameters display together that is easy to understand. Ÿ The screen contrast adjusting is easy and simply. Ÿ The compensation temperature can be measured automatically or input manually. Ÿ The intelligent measuring and automatic judge stability function to make your work easily. Ÿ Several kinds of calibration, easy for operation. TECHNOCRACY PVT. LTD.
  • 3. R Key Usages Water Treatment: pH Measurement of Wetlands, Sewage Treatment, pH in flocculation tanks, Water Purification, Water Treatment, pH measurements on water filters Use for batch control, on-line control of incoming process water, effluent system treatment water and waste water treatment. General : Useful for any batch or on-line type application that requires accurate pH or ORP control. Industrial : pH control in fume cupboards, Metal Finishing, Chemical process, Pharmaceutical production, Drug research, Fermentation and waste control industries. Regulatory : Hook to recorder to document data for regulatory compliance. Technical Specifications Measuring Range: pH value:(0.00~14.00) pH mv: ( -1000~+1000)mV Temperature:(0.0~99.9)°c ATC:(0.1~60)°c Precision: temperature:0.1°C pH value:±0.02pH temperature:±0.5? Responding Time: At 25℃, reach 90% of the changing in 90s Current Output: (0~10)mA, (0-20)mA Current Output Precision: ±1%F.S Max. Load Resistance: 800Ω(20mA max.) Alarm Output: Two channel alarm output Ambient Temperature: (5~45)°C Ambient Humidity: ≤90%RH(no condensation) Transportation Temperature.: (-25~55)℃(the transportation temp. should be higher than 0°C for electrode Overall Dimension: 158 (W x 158 H) x 170 (D) (mm) Panel Cutout: 140mm×140mm Power Supply: (85~265)VAC, (50~60)Hz Power Consumption: ≤8VA Insulation: Power to ground 1500V/1min no arcing Gross Weight: 2Kg TECHNOCRACY PVT. LTD.
  • 4. An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485 WHO: GMP Products | GLP Compliant Products www.acmasindia.com | www.cleanroom-equipments.com | www.measuring-meters.com TECHNOCRACY PVT. LTD. SALES OFFICE (INDIA) Office no. 506 & 507, 5th Floor, Plot no.- C-9, Pearls Best Height-II, Netaji Subhash Place, Pitam Pura, Delhi- 110034 Land Line No.: +91 - 11- 47619688, Fax: +91-11-47619788 E-mail.: info@acmasindia.com SALES OFFICE (HONG KONG) Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East, Sheung Wan, Hong Kong (PRC) Tel.: 0086-13929598046 0086- 18922303099 E-mail.: hk@acmasindia.com SHOWROOM J-284 Sector 1 Bawana Industrial Estate, Bawana, Delhi, INDIA-110039 Tel.: 0091-0-9312219738 (M) +91- 9717741167 E-mail.: info@acmasindia.com SALES OFFICE (RUSSIA) Inmed Trade Street Ozerkovsky Embankment, Unit No 50, Straine- 1, Off- 502, Moscow, Russia E-mail.: info@acmasindia.com Tel.: 0049- 79592345 | Email: russia@acmasindia.com