    Ashrae Lighting Compliance Document Ashrae Lighting Compliance Document Document Transcript

    • Lighting Compliance Documentation Page 1Project Name:Project Address: Date:Designer of Record: Telephone:Contact Person: Telephone:City:Mandatory Provisions Checklist Automatic lighting shutoff controls are For spaces less than or equal to 10,000 ft², a Case lighting has a separate control. provided based on either a scheduling device separate space control is provided for each or an occupant sensor. 2,500 ft² of area. Hotel/motel guest rooms have a master switch at the main entry. Exception: Space is intended for 24- For spaces more than 10,000 ft², a separate hour operation. space control is provided for each 10,000 ft² Task lighting has a separate control. Exception: Space is smaller than 5,000 of area. Nonvisual lighting has a separate control. ft². Either a photosensor or an astronomical time Demonstration lighting has a separate Each space enclosed by ceiling-height switch controls exterior lighting applications. control. partitions has an independent, accessible Exception: Lights must remain on for control that operates general lighting in the safety, security or eye adaptation Exit signs larger than 20 W have an efficacy space. reasons. greater than or equal to 35 lumens/W. Exception: The control is located in a Exterior luminaires greater than 100 W have remote location for safety or security Two-lamp tandem-wired ballasts. lamps with minimum efficacy of 60 lumens/W. reasons. Display lighting has a separate control. Exception: Luminaire is activated with a motion sensor.Interior Lighting Power Allowance (Building Area Method) Building Lighting Power Density Building Area Lighting Power Allowance Type (W/ft²) (ft²) (W) TotalInterior Lighting Power Allowance (Space-by-Space Method) Building Common/Specific Lighting Power Density Space Area Lighting Power Allowance Type Space Type (W/ft²) (ft²) (W) TotalANSI/ASHRAE/IESNA Standard 90.1-2001© 2001 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • Lighting Compliance Documentation Page 2 Project Name:Contact Person: Telephone:Interior Connected Lighting Power TypeID Luminaire Description Number of Watts/ Total Line-Voltage Track Low-Voltage Track (including number of lamps per fixture, watts per lamp, type of Luminaires Luminaire Watts ballast, type of fixture) Incandescent Fluorescent Other HID ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ TotalAdditional Interior Lighting Power Allowance TypeSpace ID Space Name Area (ft²) Unit Allowance Allowance Luminaire Installed Display Lighting (W/ft²) (W) ID’s Power (W) Decorative VDT’s ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ANSI/ASHRAE/IESNA Standard 90.1-2001
    • Lighting Compliance Documentation Page 3Project Name:Contact Person: Telephone:Additional Interior Connected Lighting Power TypeID Luminaire Description Number of Watts/ Total Line-Voltage Track Low-Voltage Track (including number of lamps per fixture, watts per lamp, type Luminaires Luminaire Watts of ballast, type of fixture) Incandescent Fluorescent Other HID ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ TotalExterior Building Lighting Power Allowance (except façades)Application Allowance Area or Length (ft² or ft) Total Watts 2Building entrance with canopy or free standing 3 W/ft of canopied areaBuilding entrance without canopy 33 W/lin ft of door widthBuilding exit 20 W/lin ft of door width TotalExterior Connected Lighting Power (except façades)ID Luminaire Description (including number of lamps per fixture, watts per lamp, type Number of Watts/ Total of ballast, type of fixture) Luminaires Luminaire Watts TotalBuilding Façades Lighting Power AllowanceApplication Allowance Area or Length (ft² or ft) Total Watts 2Building façades 0.25 W/ft of illuminated façade areaBuilding Façades Connected Lighting PowerID Luminaire Description (including number of lamps per fixture, watts per lamp, type Number of Watts/ Total of ballast, type of fixture) Luminaires Luminaire Watts TotalANSI/ASHRAE/IESNA Standard 90.1-2001