8/20/2010                                      Deficiency Report                                      Page 1 of 15        ...
8/20/2010                                    Deficiency Report                                             Page 2 of 15   ...
8/20/2010                                      Deficiency Report                                        Page 3 of 15      ...
8/20/2010                                     Deficiency Report                                           Page 4 of 15    ...
8/20/2010                                       Deficiency Report                                         Page 5 of 15    ...
8/20/2010                                    Deficiency Report                                        Page 6 of 15        ...
8/20/2010                                    Deficiency Report                                             Page 7 of 15   ...
8/20/2010                                      Deficiency Report                                           Page 8 of 15   ...
8/20/2010                                   Deficiency Report                                          Page 9 of 15       ...
8/20/2010                                   Deficiency Report                                        Page 10 of 15        ...
8/20/2010                                     Deficiency Report                                            Page 11 of 15  ...
8/20/2010                                   Deficiency Report                                         Page 12 of 15       ...
8/20/2010                                    Deficiency Report                                       Page 13 of 15        ...
8/20/2010                                       Deficiency Report                                     Page 14 of 15       ...
8/20/2010                                     Deficiency Report                                               Page 15 of 1...
Florida Department of Agriculture and Consumer Services                                                             Divisi...
SECTION 3 - OBSTRUCTIONS AND INACCESSIBLE AREAS: The following areas of the structure(s) inspected were obstructed or inac...
DACS 13645, Rev 05/08Page 3 of 7
DACS 13645, Rev 05/08Page 4 of 7
DACS 13645, Rev 05/08Page 5 of 7
DACS 13645, Rev 05/08Page 6 of 7
DACS 13645, Rev 05/08Page 7 of 7
Upcoming SlideShare
Loading in...5
×

Sample report

443

Published on

Published in: Technology, Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
443
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
5
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Sample report

  1. 1. 8/20/2010 Deficiency Report Page 1 of 15 5th Avenue Building Inspections Providing Real Estate, Insurance, Termite & Indoor Air Quality Inspections For Residential, Commercial & New Construction Ph#: (561) 369-8363 SAMPLE REPORTSITE/GROUNDS05. Sprinkler System NEEDS REPAIR: Inoperable-not priming. Heads: spraying onto structure-evidence of flooding on areas adjoining enclosed room. Location: exterior of enclosed room. Repair cost estimate: $200±.08. Driveway NEEDS REPAIR: Asphalt driveway: significant damaged-deterioration. Repair cost estimate: $400±. 5TH AVENUE BUILDING INSPECTIONS INC. * ""PROTECTING HOMEBUYERS SINCE 1989"" * www.HOUSEINSPECTORS.ORG. UNAUTHORIZED USE OF THIS REPORT IS PROHIBITED
  2. 2. 8/20/2010 Deficiency Report Page 2 of 15 5th Avenue Building Inspections Providing Real Estate, Insurance, Termite & Indoor Air Quality Inspections For Residential, Commercial & New Construction Ph#: (561) 369-8363EXTERIOR AREAS04. Stucco Walls NEEDS REPAIR: Frame wall: significant cracks-risk of water intrusion. Location: outside of master bath-scattered locations. Repairperson should check all perimeter areas prior to making repairs. Repair cost estimate: $300±.09. Exterior Areas NEEDS REPAIR: Metal post: loose-not set properly, needs permanent repairs. Location: porch at front. Repair cost estimate: $300±.ROOF/ATTIC05. Roof Edge/Overhang NEEDS REPAIR: Leak stains indicating evidence of edge leak on exterior overhang. Location: 1. 2nd floor over garage door. 2. 2nd floor left side. 3. rear over balcony. Budget additional expense for removal of gutters attached to fascia board to facilitate repairs. 5TH AVENUE BUILDING INSPECTIONS INC. * ""PROTECTING HOMEBUYERS SINCE 1989"" * www.HOUSEINSPECTORS.ORG. UNAUTHORIZED USE OF THIS REPORT IS PROHIBITED
  3. 3. 8/20/2010 Deficiency Report Page 3 of 15 5th Avenue Building Inspections Providing Real Estate, Insurance, Termite & Indoor Air Quality Inspections For Residential, Commercial & New Construction Ph#: (561) 369-8363 Leak stains and wood rot indicating evidence of edge leak on exterior overhang. Location: 2nd floor balcony. Repair cost estimate: $2,500±.HEATING/COOLING08. Air Handler Unit NEEDS REPAIR: Coils-interior: dirt-debris buildup. Location of unit: A/C closet. Repair cost estimate: $300±. 5TH AVENUE BUILDING INSPECTIONS INC. * ""PROTECTING HOMEBUYERS SINCE 1989"" * www.HOUSEINSPECTORS.ORG. UNAUTHORIZED USE OF THIS REPORT IS PROHIBITED
  4. 4. 8/20/2010 Deficiency Report Page 4 of 15 5th Avenue Building Inspections Providing Real Estate, Insurance, Termite & Indoor Air Quality Inspections For Residential, Commercial & New Construction Ph#: (561) 369-836309. Ductwork System NEEDS REPAIR: Attic ductwork: damaged, laying on ground-should be raised, leak stains-evidence of leakage, cloth duct tape on connections-temporary fix, rip-tear on outer protective wrapping. Location: including but not limited to (3) small sections near attic hatch-sections should be replaced. FPL should be contacted for a ductwork system test and home energy rebate survey www.fpl.com/residential/savings/index.shtml. Repair cost estimate: $500±.14. Condensate System NEEDS REPAIR: Exterior drain: missing trap-creating a flood next to exterior wall/slab. Requires reposition-extension or use splashblock minimum 12" away from structure or equipment. Location: by A/C condenser unit. Repair cost estimate: $100±. 5TH AVENUE BUILDING INSPECTIONS INC. * ""PROTECTING HOMEBUYERS SINCE 1989"" * www.HOUSEINSPECTORS.ORG. UNAUTHORIZED USE OF THIS REPORT IS PROHIBITED
  5. 5. 8/20/2010 Deficiency Report Page 5 of 15 5th Avenue Building Inspections Providing Real Estate, Insurance, Termite & Indoor Air Quality Inspections For Residential, Commercial & New Construction Ph#: (561) 369-8363NEEDS REPAIR: Stains-grime indicating air leakage or not properly insulated. Location: guest bedroomcloset above front entry. Repairs may involve cleaning-replacement of affected materials and re-sealingentire vent connection using antimicrobial mastic coating sealant.Repair cost estimate: $150±.15. Support/Plenum Base NEEDS REPAIR: Support base: insulation loose-moisture stains due to prior leakage, filter frame loose. Location: A/C closet. Should be sealed with antimicrobial mastic coating due to moist air flow and exposure to condensation. NEEDS REPAIR: Microbial growth-high humidity splotches buildup on support base, wall behind air handler, ceiling penetrations. Minimal remediation would require removal-cleaning and disinfecting affected area per EPA guidelines (www.epa.gov/mold/moldcleanup.html). Location: garage. Repair cost estimate: Depends on mold remediation assessments and estimating process 5TH AVENUE BUILDING INSPECTIONS INC. * ""PROTECTING HOMEBUYERS SINCE 1989"" * www.HOUSEINSPECTORS.ORG. UNAUTHORIZED USE OF THIS REPORT IS PROHIBITED
  6. 6. 8/20/2010 Deficiency Report Page 6 of 15 5th Avenue Building Inspections Providing Real Estate, Insurance, Termite & Indoor Air Quality Inspections For Residential, Commercial & New Construction Ph#: (561) 369-8363ELECTRICAL SYSTEM08. Receptacles NEEDS REPAIR: Weatherproof cover: missing, water intrusion. Location of outlet: rear side area. Hot and neutral wires reversed-unsafe wiring (reverse polarity). Outlet working with risk of shock hazard. Location of outlet: left/front guest bedroom. Ungrounded-unsafe wiring (missing ground). Outlet working with risk of shock hazard. Location of outlet: master bedroom. Repair cost estimate: $150±.10. General Wiring NEEDS REPAIR: Electrical wiring: splices exposed-missing cover. Location: exterior rear by pool transformer panel. A/C #1 breaker burnt-scorched. Location of panel: exterior by electric 5TH AVENUE BUILDING INSPECTIONS INC. * ""PROTECTING HOMEBUYERS SINCE 1989"" * www.HOUSEINSPECTORS.ORG. UNAUTHORIZED USE OF THIS REPORT IS PROHIBITED
  7. 7. 8/20/2010 Deficiency Report Page 7 of 15 5th Avenue Building Inspections Providing Real Estate, Insurance, Termite & Indoor Air Quality Inspections For Residential, Commercial & New Construction Ph#: (561) 369-8363 meter. Repair cost estimate: $200±.13. Light Fixtures NEEDS REPAIR: Fluorescent lights: inoperable-replace bulbs first. Location: kitchen. Fluorescent lights: tube bulbs flickering. Location: laundry room. Repair cost estimate: $300±.PLUMBING SYSTEM04. Water Heater NEEDS REPAIR: Pressure relief discharge pipe: reduced in size-must be approved 3/4". On interior installation: extent to exterior to prevent random dripping onto interior contents. Repair cost estimate: $150±. 5TH AVENUE BUILDING INSPECTIONS INC. * ""PROTECTING HOMEBUYERS SINCE 1989"" * www.HOUSEINSPECTORS.ORG. UNAUTHORIZED USE OF THIS REPORT IS PROHIBITED
  8. 8. 8/20/2010 Deficiency Report Page 8 of 15 5th Avenue Building Inspections Providing Real Estate, Insurance, Termite & Indoor Air Quality Inspections For Residential, Commercial & New Construction Ph#: (561) 369-8363BATHROOMS01. Bathrooms NEEDS REPAIR: Water hammering noise when hot water faucets are turned off rapidly. Most of the time this condition can be corrected by closing main valve and opening all faucet fixtures to allow air chambers to fill with air or installing air chambers arrestors. Location: master bath. Repair cost estimate: $200±.03. Shower/Tub Stall NEEDS REPAIR: Tub & shower tiles: grout failure-fungus, gaps, and grime buildup on wall next to guest tub. Location: guest-master bathrooms. Repair cost estimate: $300±. 5TH AVENUE BUILDING INSPECTIONS INC. * ""PROTECTING HOMEBUYERS SINCE 1989"" * www.HOUSEINSPECTORS.ORG. UNAUTHORIZED USE OF THIS REPORT IS PROHIBITED
  9. 9. 8/20/2010 Deficiency Report Page 9 of 15 5th Avenue Building Inspections Providing Real Estate, Insurance, Termite & Indoor Air Quality Inspections For Residential, Commercial & New Construction Ph#: (561) 369-8363INTERIOR AREAS04. Interior Areas NEEDS REPAIR: Moisture evidence-stains-evidence of leakage, plaster damage on wall under windows. Location: enclosed room. Requires further evaluation. Repair cost estimate: $300±.05. Windows NEEDS REPAIR: Crank missing, damaged-inoperable. Location: including but not limited to kitchen, living room, guest bath, enclosed room. Bottom frame: water intrusion-evidence of leakage at bottom frame, carpet tack strips stained. Repairs may involve waterproofing exterior-interior frame flashing/fasteners. Location: 1. master bedroom door (2). 2. Dining room. Repair cost estimate: $300±. 5TH AVENUE BUILDING INSPECTIONS INC. * ""PROTECTING HOMEBUYERS SINCE 1989"" * www.HOUSEINSPECTORS.ORG. UNAUTHORIZED USE OF THIS REPORT IS PROHIBITED
  10. 10. 8/20/2010 Deficiency Report Page 10 of 15 5th Avenue Building Inspections Providing Real Estate, Insurance, Termite & Indoor Air Quality Inspections For Residential, Commercial & New Construction Ph#: (561) 369-836309. Slider Doors NEEDS REPAIR: Track-rollers: dragging not working-rolling properly. Location: kitchen nook. Repair cost estimate: $150±KITCHEN/LAUNDRY01. Kitchen Plumbing NEEDS REPAIR: Faucet handle: minor leakage when operated-repair involves replacing internal parts or entire faucet. Location: kitchen. Repair cost estimate: $100±. 5TH AVENUE BUILDING INSPECTIONS INC. * ""PROTECTING HOMEBUYERS SINCE 1989"" * www.HOUSEINSPECTORS.ORG. UNAUTHORIZED USE OF THIS REPORT IS PROHIBITED
  11. 11. 8/20/2010 Deficiency Report Page 11 of 15 5th Avenue Building Inspections Providing Real Estate, Insurance, Termite & Indoor Air Quality Inspections For Residential, Commercial & New Construction Ph#: (561) 369-836302. Laundry Plumbing NEEDS REPAIR: Washer shut-off valve handles: broken. Gate valves should be replaced with a lever ball type to improve efficiency. Repair cost estimate: $150±.POOL/SPA SYSTEM08. Pool Electrical NEEDS REPAIR: Bonding wiring for pump motor: missing. Bonding of all metal around pool is required to maintain the same voltage potential per the NEC-consult pool contractor. Repair cost estimate: $150±. 5TH AVENUE BUILDING INSPECTIONS INC. * ""PROTECTING HOMEBUYERS SINCE 1989"" * www.HOUSEINSPECTORS.ORG. UNAUTHORIZED USE OF THIS REPORT IS PROHIBITED
  12. 12. 8/20/2010 Deficiency Report Page 12 of 15 5th Avenue Building Inspections Providing Real Estate, Insurance, Termite & Indoor Air Quality Inspections For Residential, Commercial & New Construction Ph#: (561) 369-836310. Drain/Skimmer NEEDS REPAIR: Spa bottom floor drain cover: loose-not secured properly. Repair cost estimate: $100±.11. Filter/Pipes REPAIR/REPLACE: Filter damaged-inoperable: internal components. Repair cost estimate: $300±. 5TH AVENUE BUILDING INSPECTIONS INC. * ""PROTECTING HOMEBUYERS SINCE 1989"" * www.HOUSEINSPECTORS.ORG. UNAUTHORIZED USE OF THIS REPORT IS PROHIBITED
  13. 13. 8/20/2010 Deficiency Report Page 13 of 15 5th Avenue Building Inspections Providing Real Estate, Insurance, Termite & Indoor Air Quality Inspections For Residential, Commercial & New Construction Ph#: (561) 369-836312. Pool/Spa Heater NEEDS REPAIR: Pool heater digital panel: damaged cover. Repair cost estimate: $150±. 5TH AVENUE BUILDING INSPECTIONS INC. * ""PROTECTING HOMEBUYERS SINCE 1989"" * www.HOUSEINSPECTORS.ORG. UNAUTHORIZED USE OF THIS REPORT IS PROHIBITED
  14. 14. 8/20/2010 Deficiency Report Page 14 of 15 5th Avenue Building Inspections Providing Real Estate, Insurance, Termite & Indoor Air Quality Inspections For Residential, Commercial & New Construction Ph#: (561) 369-8363Electric heater inoperable-unable to test-system not working due to damaged pool filter.03. Pool Equipment NEEDS REPAIR. Support base: damaged-using temporary-unconventional support. Repair cost estimate: $200±14. Pool Site NEEDS REPAIR: Fence gate: locking hardware damage-inoperable, not closing properly. Location: right side area. Repair cost estimate: $150±. 5TH AVENUE BUILDING INSPECTIONS INC. * ""PROTECTING HOMEBUYERS SINCE 1989"" * www.HOUSEINSPECTORS.ORG. UNAUTHORIZED USE OF THIS REPORT IS PROHIBITED
  15. 15. 8/20/2010 Deficiency Report Page 15 of 15 5th Avenue Building Inspections Providing Real Estate, Insurance, Termite & Indoor Air Quality Inspections For Residential, Commercial & New Construction Ph#: (561) 369-836307. Pump/Motor: NEEDS REPAIR. Bubbles in jets inside pool indicating air intrusion-requires further evaluation.Pool pump: Leaking at pump to motor connection.Repair cost estimate: $300±. 5TH AVENUE BUILDING INSPECTIONS INC. * ""PROTECTING HOMEBUYERS SINCE 1989"" * www.HOUSEINSPECTORS.ORG. UNAUTHORIZED USE OF THIS REPORT IS PROHIBITED
  16. 16. Florida Department of Agriculture and Consumer Services Division of Agricultural Environmental Services WOOD-DESTROYING ORGANISMS INSPECTION REPORT Section 482.226, Florida Statutes and Chapter 5E-14.142,F.A.C. SECTION 1 - GENERAL INFORMATION Inspection Company: 5th Avenue Building Inspections Business License Number: JB104982 Inspection Company Name Phone Number: (561) 369-8363 Company Address7456 Liverpool Ct. Boynton Beach, FL 33472 Date of Inspection: XXXXXX Company City, State and Zip CodeInspectors Name and Identification Card Number: Joey Caballero JE61018 Print Name ID Card No.Address of Property Inspected: XXXXX Avenue, Delray Beach, FLStructure(s) on Property Inspected: Single Family Home.Inspection and Report requested by: XXXXXXX Name and Contact InformationReport Sent to Requestor and to: Client. Name and Contact Information if different from above SECTION 2 - INSPECTION FINDINGS - CONSUMERS SHOULD READ THIS SECTION CAREFULLY THIS REPORT IS MADE ON THE BASIS OF WHAT WAS VISIBLE AND READILY ACCESSIBLE AT THE TIME OF INSPECTION AND DOES NOT CONSTITUTE A GUARANTEE OF THE ABSENCE OF WOOD-DESTROYING ORGANISMS (WDOs) OR DAMAGE OR OTHER EVIDENCE UNLESS THIS REPORT SPECIFICALLY STATES HEREIN THE EXTENT OF SUCH GUARANTEE. This report does not cover areas such as, but not limited to, those that are enclosed or inaccessible, areas concealed by wall-coverings, floor coverings, furniture, equipment, stored articles, insulation or any portion of the structure in which inspection would necessitate removing or defacing any part of the structure. This property was not inspected for any fungi other than wood-decaying fungi, and no opinion on health related effects or indoor air quality is provided or rendered by this report. Individuals licensed to perform pest control are not required, authorized or licensed to inspect or report for any fungi other than wood-destroying fungi, nor to report or comment on health or indoor air quality issues related to any fungi. Persons concerned about these issues should consult with a certified industrial hygienist or other person trained and qualified to render such opinions. A wood-destroying organism (WDO) means an arthropod or plant life which damages and can reinfest seasoned wood in a structure, namely, termites, powder post beetles, old house borers, and wood-decaying fungi. NOTE: This is NOT a structural damage report. It should be understood that there may be damage, including possible hidden damage present. FURTHER INVESTIGATION BY QUALIFIED EXPERTS OF THE BUILDING TRADE SHOULD BE MADE TO DETERMINE THE STRUCTURAL SOUNDNESS OF THE PROPERTY. Based on a visual inspection of accessible areas, the following findings were observed: (See Page 2, Section 3 to determine which areas of the inspected structure(s) may have been inaccessible.)A. NO visible signs of WDO(s) (live, evidence or damage) observed.B. X VISIBLE evidence of WDO(s) was observed as follows: 1. LIVE WDO(s) : (Common Name of Organism and Location) X 2. EVIDENCE of WDO(s) (dead wood-destroying insects parts, frass, shelter tubes, exit holes, or other evidence): 1. Wood Destroying Organism frass/galleries: attic several areas. 2. Wood decaying fungi (damaged wood): exterior fascia trim at front and right side at numerous areas. (Common Name, Description and Location - Describe evidence) X 3. DAMAGE caused by WDO(s) was observed and noted as follows: 1. Wood Destroying Organism frass/galleries: attic several areas. 2. Wood decaying fungi (damaged wood): exterior fascia trim at front and right side at numerous areas. (Common Name, Description and Location of all visible damage - Describe damage) DACS 13645, Rev 05/08 Page 1 of 7
  17. 17. SECTION 3 - OBSTRUCTIONS AND INACCESSIBLE AREAS: The following areas of the structure(s) inspected were obstructed or inaccessible.NO INFORMATION on the status of wood-destroying organisms or damage from wood-destroying organisms in these areas is provided in thisreport. In addition to those areas described in consumer information on Page 1, Section 2; the following specific areas were not visible and/or accessible for inspection. The descriptions and reasons for inaccessibility are stated below: X Attic SPECIFIC AREAS: Unable to be fully traverse attic/roof structure areas. REASON: Insulation, general wiring, HVAC system, structure design-clearance of areas less than 48" height and 22" in width. X Interior SPECIFIC AREAS: Interior baseboards, walls, and floor areas. REASON: Covered with furniture, personal items, cabinets, wall coverings, and floor coverings. X Exterior SPECIFIC AREAS: Perimeter foundation, areas above roof or (10) feet above ground floor. REASON: Landscaping, shrubbery, mulch, wall siding, and obstructions. Crawlspace SPECIFIC AREAS: N/A REASON: X Other: SPECIFIC AREAS: General access disclaimer. REASON: Dismantling and/or destructive work to provide access not within the scope of inspection. SECTION 4 - NOTICE OF INSPECTION AND TREATMENT INFORMATION EVIDENCE of previous treatment observed: [ ] Yes [X] No If Yes, the structure exhibits evidence of previous treatment. List what was observed: (State what visible evidence was observed to suggest previous treatment) NOTE: The inspecting company can give no assurance with regard to work done by other companies. The company that performed the treatment should be contacted for information on treatment history and any warranty or service agreement which may be in place. A Notice of Inspection has been affixed to the structure at: Attic access. (State the location) This Company has treated the structure(s) at the time of the inspection [ ] Yes [X] No If Yes: Common name of organism treated: (Common name of organism) Name of Pesticide Used: Terms and Conditions of Treatment: Method of treatment: [ ] Whole structure [ ] Spot treatment: Specify Treatment Notice Location: SECTION 5 - COMMENTS AND FINANCIAL DISCLOSURE Comments: No warranty or guarantee is expressed or implied. Warranties are available from Pest Control Company who provides the treatment or have previously treated the property. Recommend yearly inspection since there are numerous areas not readily accessible during the initial inspection. Neither the company (licensee) nor the inspector has any financial interest in the property inspected or is associated in any way in the transaction or with any party to the transaction other than for inspection purposes.Signature of Licensee or Agent: Joey Caballero Date: XXXXXXXAddress of Property Inspected: XXXXXX, Delray Beach, FL Inspection Date: XXXXXXX DACS 13645, Rev 05/08 Page 2 of 7
  18. 18. DACS 13645, Rev 05/08Page 3 of 7
  19. 19. DACS 13645, Rev 05/08Page 4 of 7
  20. 20. DACS 13645, Rev 05/08Page 5 of 7
  21. 21. DACS 13645, Rev 05/08Page 6 of 7
  22. 22. DACS 13645, Rev 05/08Page 7 of 7

×