  1. 1. NORTHERN COALFIELD LIMITED PRESENTED BY:- ANUJ KUMAR ELECTRICAL ENGINEERING B.TECH FINAL YEAR
  2. 2. CONTENTS Introduction Place of training Main substation Classiffication of transformer Parts of transformer Transformer oil filteration s
  3. 3. NORTHERN COALFIELD LIMITED It is subsidiary of coal India. It was established in 1984 under the CCL. Its headquarter is singrau NCL produced 70.02 million tons of coal in the year 2012-13. NCL has following projects:- Amlohri Block-B Bina Dudhichua Kakri Khadia Nigahi Krishnashila Jayant Jhingurdah INTRODUCTION
  4. 4. PLACE OF TRAINING The place of training is Jhingurdah project in E&M department.  E&M department has following area: -  Main substation (33/11KV)  Electrical and mechanical workshop  West substation (11/6.6KV & 11/3.3KN)  Coal handling plant  Pumps plant  I worked only three of them  Main substation (33/11KV)  Electrical workshop  West substation (11/6.6KV & 11/3.3KN)
  5. 5. MAIN SUBSTATION The supply (33/11KV) is from MPEB substation. In this substation 05 MVA transformer are used to step down the voltage 33KV to 11 KV. Form this substation 11KV supply is transmitted to following are:- West substation Colony Field CHP
  6. 6. TRANSFORMER
  7. 7. COMPONENTS OF TRANSFORMER Core Primary & secondary winding Oil tank Transformer oil Oil inlet and outlet valve Oil gauge/indicator Primary and secondary terminal Earth point Data plate Explosion vent Conservator Breather Silica gel Buchholz relay Temperature gauge Tapping switch
  8. 8. CLASSIFICATION OF TRANSFORMER On the basis of output voltage 1. Step up 2.Step down On the basis of core construction 1. Core type 2. Shell type On the basis of no. of phase 1. Single phase 2. Three phase On the basis of cooling system 1.Naturally cooled 2.Oil cooled 3.water cooled 4.forced air cooled On the basis of output capacity 1.Auto transformer 2.Instrument transformer  On the basis of commercial 1.Power transformer 2.Distribution transformer
  9. 9. TRANSFORMER USED IN SUBSTATION  Current transformer  It is step up transformer or current step down transformer.  It convert 100-200A of primary to 1-2A of secondary.  Potential transformer  It is step down transformer.  It convert 11-22KV into 50-100V.
  10. 10. TRANSFORMER OIL FILTRATION METHOD